Biddle 220070_Series_UG 电路图.pdf
《Biddle 220070_Series_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle 220070_Series_UG 电路图.pdf(78页珍藏版)》请在收音机爱好者资料库上搜索。
1、AVTM22-726Jc Rev A May 2005 Instruction Manual for the DC Dielectric Test Sets Catalog Nos. 220070: 70kV Digital Metering 220072: 70kV Analog Metering 220123: 120 kV Digital Metering 220124: 120 kV Analog Metering 220163: 160 kV Digital Metering 220164: 160 kV Analog Metering High-Voltage Equipment
2、Read the entire manual before operating. Aparato de Alto Voltaje Antes de operar este producto lea este manual enteramente. M M Valley Forge Corporate Center 2621 Van Buren Avenue Norristown, PA 19403 U.S.A. RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 DC Dielectric Test Sets Catalog Nos. 220070:
3、 70kV Digital Metering 220072: 70kV Analog Metering 220123: 120 kV Digital Metering 220124: 120 kV Analog Metering 220163: 160 kV Digital Metering 220164: 160 kV Analog Metering RadioFans.CN 收音机爱 好者资料库 Copyright 1993 - 2005 by Megger. All rights reserved. The information presented in this manual is
4、believed to be adequate for the intended use of the product. If the product or its individual instruments are used for purposes other than those specified herein, confirmation of their validity and suitability must be obtained from Megger. i AVTM22-726Jc Rev A May 2005 TABLE OF CONTENTS 1 INTRODUCTI
5、ON.1 Receiving Instructions.1 General Information.1 2 SAFETY.5 General.5 General Safety Precautions for DC Testing.5 3 SPECIFICATIONS.9 Electrical.9 Safety Features.11 Physical Characteristics.12 Environmental.13 Additional Accessories WARNING Warning, as used in this manual, is defined as a conditi
6、on or practice which could result in personal injury or loss of life. CAUTION Caution, as used in this manual, is defined as a condition or practice which could result in damage to or destruction of the equipment or apparatus under test. 9 AVTM22-726Jc Rev A May 2005 3 SPECIFICATIONS Electrical Tabl
7、e 1 delineates the electrical specifications for the test sets. Table 1: Specifications of Input and Output Cat. No. Input Voltage For nominal line voltage, single phase Output Voltage For nominal dc line voltage, continuously variable, negative polarity with respect to ground, less than 1 mA output
8、 current. Output Current Maximum rating (thermal) 220070 120 V (105-130 V) 50/60 Hz 5 A 0 to70 kV 5 mA for 30 min 3.5 mA continuous 220072 120 V (105-130 V) 50/60 Hz 5 A 0 to70 kV 5 mA for 30 min 3.5 mA continuous 220070-47 240 V (210-260 V/) 50/60 Hz 2.5 A 0 to70 kV 5 mA for 30 min 3.5 mA continuou
9、s 220072-47 240 V (210-260 V/) 50/60 Hz 2.5 A 0 to70 kV 5 mA for 30 min 3.5 mA continuous 220123 120 V (105-130 V) 50/60 Hz 10 A 0 to120 kV 5 mA for 20 min 2.5 mA continuous 220124 120 V (105-130 V) 50/60 Hz 10 A 0 to120 kV 5 mA for 20 min 2.5 mA continuous 220123-47 240 V (210-260 V) 50/60 Hz 5 A 0
10、 to120 kV 5 mA for 5 min 2 mA continuous M 10 AVTM22-726Jc Rev A May 2005 Cat. No. Input Voltage For nominal line voltage, single phase Output Voltage For nominal dc line voltage, continuously variable, negative polarity with respect to ground, less than 1 mA output current. Output Current Maximum r
11、ating (thermal) 220124-47 240 V (210-260 V) 50/60 Hz 5 A 0 to120 kV 5 mA for 5 min 2 mA continuous 220163 120 V (105-130 V) 50/60 Hz 10 A 0 to160 kV 5 mA for 20 min 2 mA continuous 220164 120 V (105-130 V) 50/60 Hz 10 A 0 to160 kV 5 mA for 20 min 2 mA continuous 220163-47 240 V (210-260 V) 50/60 Hz
12、5 A 0 to160 kV 5 mA for 5 min 1.5 mA continuous 220164-47 240 V (210-260 V) 50/60 Hz 5 A 0 to160 kV 5 mA for 5 min 1.5 mA continuous Ripple is less than 2 percent on capacitive test samples at continuous-rated output values. Regulation is less than 20 percent from no-load to continuous-rated output
13、current. Special internal guard circuit eliminates the extra meter connection lead required on most dc test sets. The simplified guard circuit reduces internal leakage current to less than 0.1 A at full-rated output voltage. Guard terminal on HV output cable allows optional connection to test sample
14、. VOLTMETER 220070 and -47 220123 and -47 220163 and -47 Digital voltmeter: 0 70 kV Resolution: 100 volts Accuracy: 2% of reading + 100 volts 220072 and -47 4.5, Analog voltmeter: 0 40 kV, 0 80 kV Resolution: 1 kV/ 2 kv Accuracy: 2% of full scale SPECIFICATIONS 11 AVTM22-726Jc Rev A May 2005 220124
15、and -47 4.5, Analog voltmeter: 0 60 kV, 0 120 kV Resolution: 1 kV/ 2 kV Accuracy: 2% of full scale 220164 and -47 4.5, Analog voltmeter: 0 80 kV, 0 160 kV Resolution: 2 kV/ 4 kV Accuracy: 2% of full scale AMMETER 220070 and -47 220123 and -47 220163 and -47 Digital ammeter: 0 19.9, 0 199 A, 0 1.99,
16、0 5.00mA Accuracy: 2% of reading + 1 count 220072 and -47 220124 and -47 220164 and -47 4.5, Analog ammeter: 0 5 A Multipliers: x1k, x100, x10, x1 Maximum Resolution: 0.1 A Accuracy: 2% of full scale All high-voltage components are encapsulated or sealed in dielectric housing for high reliability an
17、d minimum size and weight. There is a surge-limiting resistor in series with the high-voltage output and a bleed-off resistor for the discharging of charge stored in the unit. Safety Features ! Input supply line circuit breaker. ! Output current overload relay. ! Zero-start interlock for high-voltag
18、e output. ! Push-button controls for high-voltage ON and OFF. ! Indicating lights for high-voltage ON and OFF. ! Connection for external permissive and safety switches. ! Protection against damage by overloads and surges. ! Control unit separated from HV unit by 15 ft (4.6 m) of interconnection cabl
19、e. M 12 AVTM22-726Jc Rev A May 2005 Physical Characteristics CONTROL UNIT The control unit is housed in a sturdy, suitcase-style portable case. Cat. No. Dimensions Weight 220070, 220072, 220123, 2200124, 220163 and 2200164 20 x 12 x 12 in. (L x W x H) (50.8 x 30.5 x 31.8 cm) 23 lb (10.5 kg) 220070-4
20、7, 220072-47, 220123-47, 2200124-47, 220163-47 and 2200164-47 20 x 12 x 12 in. (L x W x H) (50.8 x 30.5 x 31.8 cm) 25 lb (11.4 kg) HV UNIT The HV unit is housed in a high-impact strength polyethylene housing with an adjustable shoulder carrying strap. Cat. No. Dimensions Weight 220070 and -47 22072
21、and -47 12 x 12 x 20 in. (L x W x H) (30.5 x 30.5 x 51 cm) 44 lb (20 kg) 220123 and -47 220124 and -47 12 x 12 x 29 in. (L x W x H) 30.5 x 30.5 x 74 cm) 65 lb (30 kg) 220163 and -47 220164 and -47 12 x 12 x 29 in. (L x W x H) (30.5 x 30.5 x 100 cm) 73 lb (33 kg) CABLE CARRYING CASE The cable carryin