1、 Model: 4075, 4078 25 MHz Arbitrary Function Generator USER MANUAL RadioFans.CN 收音机爱 好者资料库 2 SERVICE INFORMATION Warranty Service: Please go the support and service section on our website to obtain a RMA #. Return the product in the original packaging with proof of purchase to the address below. Cle
2、arly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Non-Warranty Service: Please go the support and service section on our website to obtain a RMA #. Return the product in the original packaging to the address bel
3、ow. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Customers not on an open account must include payment in the form of a money order or credit card. For the most current repair charges please refer to the
4、 service and support section on our website. Return all merchandise to B press YES to execute the predefined waveform. On the NOISE function a menu of ADD and NEW is prompt to select a new noise waveform or to add noise to the existing waveform. F4: MORE - Displays the following Menu: Morel Display
5、F1: COPY - Displays the Copy menu (see the Copy Function later in this section). F2: CLEAR - Displays the Clear menu (see the Clear Function later in this section). F3: PROT - Displays the Protect menu (see the Protect Function later in this section). 29 F4: SHOW WAVE - Display the Arbitrary wavefor
6、m in full screen mode on LCD display. This is only an approximated display for quick viewing. It does not represent the exact waveform being generated. To return back to the MENU selection, press any button. Full Display Example Copy Function. Copies an area of waveform memory to another area of wav
7、eform memory. F1: FROM - Selects the address of the first point to copy. F2: LENG - Selects the length (number of points) of the waveform to copy. F3: TO - Selects the destination address where the first point is copied. F4: EXEC - Prompts you to confirm whether to copy. Press NO to abort copying, Y
8、ES to copy. Clear Function. Clears (sets the data values to zero) either a section of or all of waveform memory. F1: FROM - Selects the address of the first point to clear. F2: TO - Selects the address of the last point to clear. F3: ALL - Clears the whole waveform memory. Equivalent to selecting fr
9、om 1 to 400,000. F4: EXEC - Prompts you to confirm whether to clear. Press NO to abort clearing, YES to clear. Protect Function. Protects (makes read-only) a section of waveform memory. F1: FROM - Selects the address of the first point to protect. F2: TO - Selects the address of the last point to pr
10、otect. F3: ALL - Protects the whole waveform memory. Equivalent to selecting from 1 to 400,000. Note: You can protect only one segment of waveform memory at a time. F4: ON/OFF - Selects the unprotect mode and resets memory protection so that the whole waveform memory can be written into. 30 3.6.5 PU
11、LSE Menu Pulse Menu F2: PULSE - Selects the Pulse parameters entry. And then: F1: FREQ/PERIOD - Selects the parameter definition of the Pulse repetition period. F2: WIDTH - Selects the Width of the generated pulse. F3: EQUAL EDGE - Selects equal Rise (Leading edge) and Fall (Trailing edge) times of
12、the pulse. F4: LEAD-TRAIL - Selects different Rise and Fall times of the Pulse. 3.6.6 UTILITY Key Utility Menu F1: GPIB - (optional) Selects the GPIB remote mode of operation. After selection the GPIB address can be set to any value from 1 to 31 using the rotary knob. The value is kept in a nonvolat
13、ile memory and used at power-on. The factory default address is 9. Setting the address to 31 puts the device in the off-bus state (it will not respond to messages on the GPIB bus). F1:RS232 - Selects the RS232 remote control mode. After selection, the baud rate can be selected as 2400, 9600, and 192
14、00. The RS-232 uses 8 bit data, 1 stop bit and no parity. F2: RECALL - Recalls a previously stored front-panel setup from the selected buffer. Change the buffer number by using the rotary input knob. Valid storage buffer numbers are from 0 to 49. Buffer 0 is the factory default setup. 31 F2: STORE -
15、 Stores the current front-panel setup to the specified storage buffer. Change the buffer number by using the numeric keypad or the rotary input knob. Valid storage buffer numbers range from 1 to 49. Below is a list of parameters that can be stored in each buffer. Note: Location 50 is for last workin
16、g setup before power down. List of Stored Parameters Stored Parameters FREQUENCY RATE(ARB) AMPLITUDE FUNCTION OFFSET REPETITION MODE N-BURST START ADRS WAVELENGTH TRIG SOURCE OUTPUT SWEEP MODULATION *The RECALL and STORE function can be used as a tool to store and locate many arbitrary waveforms. Be
17、cause the 4075 and 4078 are designed with one large memory bank (up to 400,000 points of storage), users can have the freedom to store as many waveforms of different lengths as they desired in a dynamic fashion (with the limit of total points not to exceed memory capacity). Then, by using STORE and
18、RECALL functions to save the starting address and lengths of each created arbitrary waveforms, users can quickly locate (in the memory) and output each of the different waves. These functions can behave like reference points, so users can actually save up to 49 different waveform reference points in
19、 the memory. See example illustration below to see how it works: Stored Buffer number Data points of different waveforms 1 400,000 Waveform 1 Waveform 4 Waveform 2 Waveform 3 A pts. B pts. C pts. D pts. A pts. + B pts. + C pts. + D pts. 400,000 pts. Point Point 32 (Start address + length) 1 A pts. 2
20、 B pts. 3 C pts. 4 D pts. From the above illustration, all the points of Waveform 1 can be stored and recalled using buffer #1. Likewise, Waveform 2 can be stored/recalled by buffer #2. Waveform 3 by buffer #3. Waveform 4 by buffer #4. F3: POWER - (Power-on default) Selects the power-on default sett
21、ing. Select a value using the numeric keypad or the rotary input knob. The selection is effective after a 10 s time-out period. Select zero (0) to have the waveform generator power on with the factory default settings. Select 50 to have the waveform generator power-on with the settings it had at the
22、 last power-off. Select any other value in the range from 1 to 49 to have the waveform generator power-on with the settings that you have saved with F2:STORE(see above) in the range of 1 to 49. 3.6.7 SWEEP Key Selects the Sweep Mode and allows the entering of sweep parameters as Sweep Start, Sweep S
23、top and Sweep Rate. To select the sweep mode, press SWEEP, then press the function key that corresponds to the desired Sweep menu option, as shown: Sweep Menu F1: ON/OFF - Operates the sweep function, selecting between Sweep On or Off. F2: START/STOP - Defines the Sweep Start and Stop frequencies. F
24、3: RATE - Defines the Sweep Rate. F4: LIN/LOG - Selects the Sweep Shape, LIN or LOG. 33 Log Sweep Menu 3.6.7.1 How to Setup Sweep in Different Modes By default, turning ON the sweep function will automatically set to a continuous (CONT) sweep. In order to change to other modes of sweep, do the follo