Anritsu ANRITSU_MS2601B 电路图.pdf
《Anritsu ANRITSU_MS2601B 电路图.pdf》由会员分享,可在线阅读,更多相关《Anritsu ANRITSU_MS2601B 电路图.pdf(5页珍藏版)》请在收音机爱好者资料库上搜索。
1、SPECTRUM ANALYZERS For product ordering information, see pages 4-7. GPIB High-Speed Measurement of Various Devices SPECTRUM ANALYZER MS2601B/K 9 kHz to 2.2 GHz The MS2601B/K is a wide-band spectrum analyzer which covers the video to VHF/UHF bands. The synthesized local oscillator and auto- matic cal
2、ibration, which uses a highly accurate signal source, enable accurate frequency and level measurement. In addition, the MS2601B/K has new and original functions such as the zone marker and scroll function, that shorten measurement time. Furthermore, plug-in mem- ory cards (PMCs) for storing measurem
3、ent conditions and waveform data offer excellent operability. Advanced functions High-level built-in automatic calibration The MS2601B/K automatically calibrates itself using the calibration signal from the built-in signal source each time the CAL key is pressed. The calibration data is processed at
4、 high speed by a 16-bit micro- processor and the compensation value is added to the displayed measured value. The reliability of measurements has been greatly improved and the measurement error has been reduced to about one-third of conventional models, resulting in a general level mea- surement acc
5、uracy of 1 dB. Furthermore, when the working temperature changes drastically, an accurate measurement can be made just by pressing the CAL key. Digital technology supports high-accuracy measurement Digital technology, including a synthesized local signal, has been used to greatly improve the level m
6、easurement accuracy. Also, the signal peak-level frequency can be measured with 1 Hz resolution even at a 2.2 GHz full sweep. Furthermore, in addition to having a QP detec- tor, three resolution bandwidths, and time constants based on CIS- PR standards, the antenna calibration coefficients are autom
7、atically calculated to facilitate the best EMI measurement. IC cards for spectrum analyzers The age of spectrum analyzers operated by IC cards has now arrived. The MS2601B/K uses IC memory cards called PMCs to store mea- surement conditions and waveform data. For example, once the test procedures ar
8、e stored in the PMCs, measurements can be made un- der the same conditions at any time. You can keep your hard-earned measurement conditions as your personal know-how. Also, if these PMCs are used with the Personal Test Automation (PTA) program memory, automatic measurement can be packaged in a card
9、. PTA widens realm of automatic measurements The PTA function is a high-level language for measurement and a computer integrated in a spectrum analyzer. Programs for measure- ments, operation, and display, etc. can be input to the MS2601B/K via the keyboard or a personal computer. Thus, the spectrum
10、 analyzer can be configured quickly into automatic test equipment. PTA supports complicated measurements as well as preparation of final test results. The MS2601B/K can be used as a frequency counter, power meter, and real-time computer for measurement operations, or as ATE com- bining these functio
11、ns, as well as a spectrum analyzer. Also, various support software is available to enable connection to factory au- tomation LANs (local area networks). Main applications Measuring transmission quality such as spurious emissions from radio communication equipment Measuring electromagnetic interferen
12、ce (EMI) Testing high-frequency parts such as RF converters and tuners Measuring various devices such as filters and ICs Measurement examples Correct frequency count even at 2.2 GHz-span sweep The zone markers can be aligned with the desired signal even while observing the entire signal at full span
13、 sweep. A 2.2 GHz signal fre- quency can be measured at 1 Hz resolution (see below). RadioFans.CN 收音机爱 好者资料库 For product ordering information, see pages 4-165 SPECTRUM ANALYZERS 2 Model Overall level accuracy of 1 dB Reproducible high-accuracy level measurements are ensured through internal signal c
14、alibration, initiated simply by pressing the CAL key on the MS2601B/K (see below). In addition, there is little cumulative LOG linearity error so that measurements of transmission characteristics are carried out with the same high accuracy achieved by network ana- lyzers. Zone marker easily locates
15、signals. This zone marker function (patent pending) has been developed to reduce the measurement time. Simply enter zone markers around the signal frequency and the peak value within that zone will be measured with 0.03 dB resolution and displayed, even if the exact frequency varies. This eliminates
16、 troublesome marker adjustment to the signal peak each time you want to read the frequency and level(see below). The frequency- adjustment capability for an oscillator under test has been increased remarkably, and the frequency display remains visible during adjustment. Frequency axis scroll functio
17、n Sometimes the signal on the left or right of the displayed portion must be examined in detail during a slow sweep (see below). Just press the scroll key to move the display two divisions left or right on the screen. This permits areas beyond the edge of the screen to be displayed without waiting f
18、or a new sweep to display the entire waveform. EMI measurement In addition to providing a QP detector and three resolution band- widths and time constants based on CISPR standards, antenna cal- ibration coefficients are automatically calculated to facilitate easy EMI measurement. Application softwar
19、e MX4102B Transmitter Test System Software The MX4102B software can be used for efficient testing of mobile transmitter equipment that uses PTA (optional). This software can be used to measure frequency, high-order harmonic spurious compo- nents (second to fifth order harmonics), occupied bandwidths
20、, and the adjacent channel power. Specifications MS2601B 9 kHz to 2.2 GHz 0 to 2210 MHz (stop frequency: 1 kHz) 20 Hz CENTER/SPAN, START/SPAN, START/STOP Set frequency span (stop freq. start freq.) to 2 digit value (10 to 98) (100 Hz + freq. span x 2% + display freq. x reference freq. accuracy) For
21、CENTER/SPAN or START/SPAN mode, after auto-calibration, provided that freq. span is 10 kHz and sweep time is 100 s Setting range: 1 kHz to 2200 MHz for horizontal 10 divisions, 2-digit (10 to 98) variable, and 0 Hz (fixed tuning) 1 kHz to 2000 MHz, 1-2-5 sequence at step keys Readout accuracy: 2% (s
22、weep time 100 s) Resolution bandwidth: 30 Hz to 1 MHz (3 dB bandwidth), variable in 1-3 sequence, can be selected manually or automatically coupled to frequency span Resolution bandwidth accuracy: 20% Selectivity: 15 : 1 (ratio of 60 dB and 3 dB bandwidth) Residual FM: 20 Hz p-p/0.1 s (frequency spa
23、n; 500 kHz) Drift: 300 Hz/min (frequency span; 500 kHz, sweep time; 100 s, after 1-hour warm-up at constant ambient temperature) 80 dBc (at 100 Hz resolution bandwidth, 1 Hz video bandwidth, 10 kHz from signal) MS2601K Measurement frequency range Frequency setting Display resolution Setting mode Fre
24、quency display accuracy Frequency span Resolution Stability Sideband noise Frequency Continued on next page RadioFans.CN 收音机爱 好者资料库 SPECTRUM ANALYZERS For product ordering information, see pages 4-7. Continued on next page ModelMS2601BMS2601K Reference oscillator Frequency: 10 MHz Stability Starting
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Anritsu ANRITSU_MS2601B 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


