1、Microwave Connector Thread Gaging Technical Note RadioFans.CN 收音机爱 好者资料库 2 When making a microwave connection with a coaxial connector, a good ground connection must be achieved. If not, poor return loss will result. If the ground connection is loose, performance will be inconsistent and will cause
2、intermittent performance problems. Connector threads play a crucial role in achieving a good ground connection they must be made properly in order to achieve good consistent results. It has come to our attention that there may be confusion regarding the measurement of connector threads to determine
3、if they are properly made. The intention of this note is to clarify methods used to measure threads and to defi ne some terms used in thread measurement. This simplifi ed diagram shows the major features of threads that are important for this discussion Figure 1.Thread defi nition For the threads of
4、 a female K connector, the pitch diameter of a perfectly made thread is 0.2311 inches (5.870 mm) while the minimum pitch diameter is 0.2280 inches (5.791 mm). The correct fl ank angle is 60. The major diameter of the 1/4-36 thread used on the K connector is 0.250 inches (6.35 mm) and the minor diame
5、ter is designed to be 0.1885 inches (4.788 mm) while the correct pitch is 0.0278 inches (0.706 mm.) If the female thread pitch diameter is too small, it may not be possible to torque the nut to 8 in-oz or the connector may tilt as the threads are tightened. Figure 2 shows what may occur. Figure 2. U
6、ndersized Threads (exaggerated a bit) Figure 3. Properly sized Threads If the pitch diameter is too large, the specifi ed torque specifi - cation may be reached before the center pin is properly engaged, resulting in poor return loss due to excessively large pin gap. Remember that housing threads ca
7、n also cause problems tightening to the proper torque. Thread Measurements There are two primary tools used to measure threads. Go-No Go Gages The fi rst and easiest to use are Go-No Go gages. The type for external threads look similar to die used to thread rods. They come in pairs, the “Go gage” an
8、d the “No-Go gage.” The Go gage should thread on easily while the No-Go gage, whose threads are slightly smaller, should jam after 11/2turns or so. If the No-Go gage doesnt jam, this indicates that the thread is undersized. If the go-gage jams, this indicates that the threads are over-sized. The gag
9、es should be lightly lubricated with machine oil to minimize wear and prevent corrosion. Go No- Go gages comes in two types, adjustable and non-adjustable. The adjustable type has a gap as shown in fi gure 4. Ascrew sets the gap width and calibration lab personnel use the screw to calibrate the gage
10、 when compensating for wear. The non- adjustable type must be discarded when worn. For measure- ments made by these gages to be meaningful, the customer must have a process in place to regularly calibrate the gages or to determine if a gage is worn. If a worn gage is not discarded, a connector that
11、is perfectly good may be rejected. For measuring internal threads, the go-no go gage shown in Figure 5 is used. The pass/fail indications for internal threads are the same as for external threads the No-Go end of the gage should jam after 11/2turns or so. Major Diameter Pitch Diameter Minor Diameter