1、AVTM550503 Rev E March 2005 Instruction Manual AVTM550503 for Three-Phase TTR Transformer Turn Ratio Test Set Catalog No. 550503 High-Voltage Equipment Read the entire manual before operating. Aparato de Alto Voltaje Antes de operar este producto lea este manual enteramente. M Valley Forge Corporate
2、 Center 2621 Van Buren Avenue Norristown, PA 19403 U.S.A. 610-676-8500 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 Three-Phase TTR Transformer Turn Ratio Test Set Instruction Manual RadioFans.CN 收音机爱 好者资料库 Copyright Notice Copyright 1999 by Megger. All rights reserved. Disclaimer Notice The info
3、rmation contained in this manual is believed to be adequate for the intended use of the product. If the product or its individual instrument are used for purposes other than those specified herein, confirmation of their validity and suitability must be obtained from Megger. Refer to the warranty inf
4、ormation included at the end of this instruction manual. Specifications are subject to change without notice. Warranty Products supplied by Megger are warranted against defects in material and workmanship for a period of one year following shipment. Our liability is specifically limited to replacing
5、 or repairing, at our option, defective equipment. Equipment returned to the factory must be shipped prepaid and insured. This warranty does not include batteries, lamps, or other expendable items, where the original manufacturers warranty shall apply. We make no other warranty. The warranty is void
6、 in the event of abuse (failure to follow recommended operating procedures) or failure by the customer to perform specific maintenance as indicated in this manual. TABLE OF CONTENTS INTRODUCTION.1 Receiving Instructions.1 General Information.1 SAFETY.3 SPECIFICATIONS.7 Electrical.7 Environmental Con
7、ditions.9 Physical Data.10 Accessories Supplied.10 Optional Accessories.11 DESCRIPTION.13 Principle of Operation.13 TTR Operational Flow Chart.15 Controls, Indicators, and Connectors.19 SETUP AND CONNECTIONS.21 General Instructions.21 Single-Phase, Two-Winding Transformers.21 Three-Phase, Two-Windin
8、g Transformers.24 Three-Phase, Three-Winding Transformers.25 Current Transformers (CTs).26 T-Type Transformers.32 Connections and Vector Voltage Diagrams.33 OPERATION.65 General Operating Procedure.65 Description of Menus and Test Screens.65 Error Messages.85 AVTM550503 Rev E March 2005 ii Remote Co
9、ntrol Operation for LTC Testing.86 Use with the Optional Printer.87 Use with the Optional Inverter.88 COMLINK.91 Introduction.91 Installation and the X terminals on the test set must be connected to the H terminals on the CT. NOTE: Dots on the housing of the transformer are commonly used to identify
10、 terminals of the same polarity. WARNING Failure to observe proper connections will result in a safety hazard and may result in damage to the test set or CT. Failure to observe voltage rating of low- current X winding may result in damage to the CT. CAUTION Never use AUTO mode of operation when test
11、ing the current transformers with the rated voltage below 80 V ac. Most of the CTs are tested at 8 V ac excitation voltage. NOTE: Most of the current transformers are tested at 8 V ac excitation voltage. Some current transformers with turn ratio of 100:5 and less get saturated at 8V ac. They require
12、 lower excitation voltage for testing and therefore can not be tested with the Cat.No 550503 TTR. SETUP AND CONNECTIONS AVTM550503 Rev E March 2005 27 Unmounted CTs 1. Connect the wing-nut ground terminal of the test set to a low-impedance earth ground using the 15-ft (4.6 m) ground cable supplied.
13、2. Use the TTR H and X test leads and connect as follows and as shown in Figure 5-5. 3. Connect the heavy-duty clips marked H1 and H2 of the test lead to the respective X1 and X2 terminals of the CT. 4. Connect the heavy-duty clips marked X1 and X2 of the test lead to the respective H1 and H2 termin
14、als of the CT. Ensure correct polarity. Figure 5-6 shows the setup for testing the taps on a multiple-tap CT. Bushing Current Transformer (BCT) Mounted on Single-Phase, Two-Winding Transformer A turn-ratio test can be performed on a BCT after it has been mounted on a circuit breaker or power transfo
15、rmer entrance bushing. The test can be performed without removal of the BCT from the equipment. Proceed as follows and as shown in Figure 5-7. 1. Connect the wing-nut ground terminal of the test set to a low-impedance earth ground using the 15-ft (4.6 m) ground cable supplied. 2. Use the TTR two or
16、four conductor H and X test leads. 3. Short-circuit the winding on the opposite voltage side of the power transformer core, using jumper leads. 4. Connect the heavy-duty clips marked H1 and H2 of the test leads to the respective X1 and X2 terminals of the BCT. 5. Connect the heavy-duty clip marked X
17、1 to the power transformer terminal on which the BCT is mounted and the X2 heavy-duty clip to the terminal on the opposite side of the power transformer winding (H2 side of BCT). Check to make sure that the BCT is mounted with proper polarity with respect to power transformer entrance bushing and th