1、BIDDLECFL800E Bridge Time Domain Reflectometer BIDDLE User Guide RadioFans.CN 收音机爱 好者资料库 2.0 Introduction5 3.0 User Controls and Display6 4.0 Operation7 5.0 Meter7 6.0 TDR7 7.0 Instructions for Bridge 11 8.0 General Specification18 9.0 Repair and Warranty20 2 Contents RadioFans.CN 收音机爱 好者资料库 Symbols
2、 used on the instrument Caution: Refer to accompanying notes Equipment protected throughout by Double or reinforced Insulation Instrument flash tested to 3.7 kV r.m.s. for 1 min. Equipment complies with current EU Directives 3 3.7 RadioFans.CN 收音机爱 好者资料库 SAFETY WARNINGS This instrument primary use i
3、s for testing telecomm cables and so it meets the safety requirements of IEC 60950 third Edition (1999-04). It also meets the safety requirements of IEC 61010 parts 1 and 2 but without a category of installation as the instrument must not be directly connected to an energised Mains Supply. The instr
4、ument is designed for used on de-energised circuits, however, when used with telecomm cables, it may, in normal use, be subject to telecomm network voltages up to TNV-3 as defined by IEC-60950. Do not exceed the limits of this tester. If it is to be used in situations where hazardous live voltages m
5、ay be encountered then an additional blocking filter must be used to isolate the instrument. CAUTION (Risk of electric shock) Although this tester does not generate any hazardous voltages, circuits to which it can be connected could be dangerous due to electric shock hazard or due to arcing (initiat
6、ed by short circuit). While every effort has been made by the manufacturer to reduce the hazard, the user must assume responsibility for ensuring his, or her, own safety. Never connect the instrument to circuits that may be hazardous live. The instrument should not be used if any part of it is damag
7、ed. Test leads, probes and crocodile clips must be in good order, clean and with no broken or cracked insulation. Check that all lead connections are correct before making a test. Disconnect the test leads before accessing the battery compartment. Refer to operating instructions for further explanat
8、ion and precautions. Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. NOTE THE INSTRUMENTS MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. 4 Thank you for purchasing this quality AVO product. Before attempting u
9、se of your new instrument please take the time to read this user guide, ultimately this will save you time, advise you of any precautions you need to take and could prevent damage to yourself and the instrument. The BIDDLE CFL800E is an advanced instrument capable of identifying a wide range of cabl
10、e faults. It incorporates an Insulation Tester, a DC Voltmeter, Time Domain Reflectometer (TDR) and a Digital Bridge to allow for the accurate location of short and open faults on a cable. The Voltmeter measures a DC voltage to 250 V and can verify if a telecomm cable has a Telecomm Network Voltage
11、(TNV) present on it. The TDR has a range of 10 m to 3000 m. It transmits a narrow pulse of electrical energy along a pair of conductors within a cable and times how long any reflections of the pulse take to get back. By knowing how fast these pulses travel through a given cable, the measured time ca
12、n be converted to a distance to fault. The reflections are caused by impedance changes within the cable that are significantly different from the characteristic impedance of the cable. A partial to full short circuit will have a negative going reflection whereas a partial to full open circuit will h
13、ave a positive going pulse. If the change in impedance is less significant, the ability to discern the cable feature accurately using the TDR technique alone can be difficult and so the BIDDLE CFL800E provides a Digital Bridge for this occasion. The Digital Bridge can measure the insulation resistan
14、ce up to 200 M (insulation test), the loop resistance up to 2 k (2-wire loop test) and the series leg resistance of up to 1 k (3-wire loop test). Where a fault causes the insulation resistances to lie below 20 M, the fault position can be determined (AUTO test) relative to the meter end and also rel
15、ative to the far end where a loop has been made by fitting a strap between the wire under test and one or two return wires. In the case of a single return wire (2-wire test method), the position of the strap is assumed to be at the position of half the total loop resistance. If two return wires can
16、be used (3-wire test method) the position of the strap will be known to greater accuracy and will be independent of the resistance of either of the return wires. 5 2.0 INTRODUCTION 3.0 USER CONTROLS AND DISPLAY: The controls of the CFL800E have been arranged such that the instrument is easy to use a
17、nd easy to learn how to use. The precise function of each control depends on the current mode selected and is detailed as follows: Figure 1 The CFL800E Controls # NameMain MenuVoltmeterBridgeTDR 1Display-128 x 64 pixelShows current settings or measurement results relevant to the selected mode. 2TX N
18、ull - Rotating dial-Analogue control to minimise O/P pulse. 3Cursor Left - -Reduce selected valueMoves cursor left/reduces Uni-directional push buttonselected value 4Menu - Bi-directional Moves menu cursor Selects E to A or EMenu left/right ctrl andClockwise/anti-clockwise push buttonleft or rightto
19、 B V and can select EXIToption selectoroption selector. 5Cursor Right - -Increase selected valueMoves cursor right/increases Uni-directional push buttonselected value 6Power On/OffTurns the instrument On/OFF 7Gain - Bi-directional Proceeds with selected Proceed with Proceeds with selected Increases/
20、decreases gain push button Menu optionEXIT selectionMenu optionsetting, confirm EXIT. 8BacklightTurns the instrument backlight On/Off 9ContrastAnalogue control to correct the display contrast for extremes of temperature 10 O/P SocketsLabelled E, A, B any errors in the velocity factor are directly pr
21、oportional to distance measurement errors. Please refer to the Quick Reference Guide for a table of typical Velocity Factors. 6.4 PULSE WIDTHS The CFL800E pulse widths range from 8 ns to 3 s to overcome signal attenuation and enable the instrument to see further down a length of cable. In distance t
22、erms for the size of the transmitted pulse, this represents a transmitted pulse from as small as 1.5m to 600m! (This assumes a velocity factor of 0.67.) Without TX Null, this would be an enormous dead zone, but with the instrument correctly balanced, faults can be seen well within the pulse width. A
23、s the measured distance is taken at the start of the reflected pulse, the size of the pulse width does not affect the accuracy of the measurement. However, if the first feature does not give a complete reflection such that the instrument can see beyond it to a second feature, the ability to discern
24、between features is affected by the pulse widths. If there are multiple features, the instrument can only fully discern between them if the features are more than the pulse width apart. Hence, for discerning multiple features, the instrument should be used with the shortest range, and so smallest pu
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle CFL800E_UG 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf