1、 Instruction Manual for DELTA-2000 10-kV Automated Insulation Test Set Catalog No. 672001 High-Voltage Equipment Read the entire manual before operating. Aparato de Alto Voltaje Antes de operar este producto lea este manual enteramente. AVO International PO Box 9007 Valley Forge, PA 19485-1007 U.S.A
2、 610-676-8500 Shipping Address: Valley Forge Corporate Center 2621 Van Buren Avenue Norristown, PA 19403 U.S.A AVTM 672001 Rev. B October 2001 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 DELTA-2000 10-kV Automated Insulation Test Set Instruction Manual Copyright February 1997 by AVO Internationa
3、l All rights reserved. Reproduction without written permission is prohibited. Specifications are subject to change without notice. RadioFans.CN 收音机爱 好者资料库 i Table of Contents Section Page 1 Introduction.1 Receiving Instructions.1 General Information.1 2 Safety .3 Precautions.3 Warning and Caution No
4、tices.5 3 Specifications.6 Electrical.6 Environmental.8 Physical Data.9 Safety Features.10 Accessories Supplied.10 Optional Accessories.11 4 Controls, Indicators, and Connectors.12 Control Unit Front Panel.12 Control Unit Connector Panels.15 High-Voltage Unit Connector Panel.17 5 Setup and Operation
5、.18 Safety Precautions.18 Setup.18 Description of Main Menu and Test Screens.22 Ac Insulation Test Procedure.33 Transformer Excitation Current Test Procedure.36 6 Maintenance and Calibration.40 Maintenance.40 Calibration.40 Troubleshooting.48 Repair .49 7 Spare Parts List.50 Glossary.51 Warranty.53
6、Appendix A Data-Key Data Downloader Program Appendix B Applications Guide Appendix C Test Data Forms Appendix D Temperature Correction Tables ii List of Illustrations Figure Page 1 Control Panel.13 2 Connector Panel, Control Unit (Right).16 3 Connector Panel, Control Unit (Left).16 4 Connector Panel
7、, Control Unit (Front).17 5 Connector Panel, High-Voltage Unit.17 6 Typical Test Setup for Ac Insulation Testing of a Three-Phase Power Transformer .19 7 Typical Test Setup for Transformer Excitation Current Measurements.20 8 Printer Dip Switch Settings.21 9 Opening Display Screen .22 10 Self-Diagno
8、stic Results Screen.23 11 First Test Screen .23 12 First Menu Screen.25 13 Second Menu Screen .26 14 Recall Readings Submenu .28 15 Second Test Screen .29 16 Third Test Screen .30 17 Typical Test Results Screen .31 18 “New Test” Test Screen .32 19 First Test Screen if Resonating Inductor Is Connecte
9、d.32 20 Second Test Screen if Resonating Inductor Is Connected.33 21 Sample Printout (Header and Test Results) Ac Insulation Test Measurement.35 22 Test Results, Transformer Excitation Test.38 23 Sample Printout of Excitation Current Measurement.39 List of Tables Table 1 Maximum Measurable Specimen
10、Capacitance at 50/60 Hz.8 2 Definition of Status Blocks on Test Screens.24 3 Analog PCB Calibration Checks.42 4 Relay and Range/Mode PCB Calibration Checks.44 5 Function of Relays and CMOS Switches.47 1 Section 1 Introduction Receiving Instructions Check the equipment received against the packing li
11、st to ensure that all materials are present. Notify AVO International of any shortage. Telephone (610) 676-8500 and ask for the Customer Service Department. Examine the instrument for damage received in transit. If damage is discovered, file a claim with the carrier at once and notify AVO Internatio
12、nal, giving a detailed description of the damage. This instrument has been thoroughly tested and inspected to meet rigid specifications before being shipped. It is ready for use when set up as indicated in this manual. General Information The DELTA-2000 is used for shop and field testing of high-vol
13、tage electrical insulating systems at test voltages up to 12 kV. Test results can be used to evaluate the nature and quality of electrical insulating materials and manufacturing processes to reveal contamination, fractures, punctures, and other defects that accompany the aging of insulation. The tes
14、t set comprises a control unit, a high-voltage unit, cables, and a canvas carrying bag. Refer to the Specifications section for a list of included accessories. Tests are made by measuring the capacitance, power factor (dissipation factor) and dielectric losses of a specimen. The values measured will
15、 change when undesirable conditions exist, such as moisture on or in the insulation; shorts or opens in windings or insulation; the presence of conductive contaminants in insulating oil, gas or solids; and the presence of internal partial discharges. The test set measures the capacitance, power fact
16、or (dissipation factor) and dielectric losses of electrical insulation on high-voltage power equipment such as cables, bushings, insulators, circuit breakers, transformers, rotating machines, capacitors, and surge (lightning) arresters. The test set measures changes of capacitance and dielectric los