1、 INSTRUCTION MANUAL For HIGH CURRENT TEST SET MODEL MS-2 It is essential that this instruction book be read thoroughly before putting the equipment in service. RadioFans.CN 收音机爱 好者资料库 APPRECIATION We are indebted to the manufacturers of circuit breakers and motor overload relays, who have given thei
2、r time and advice in the preparation of this instruction book. IMPORTANT The information and data contained within this instruction manual are proprietary with AVO MULTI-AMP Corporation. The equipment described herein may be protected by one or more U.S. letters patent. AVO MULTI-AMP specifically re
3、serves to itself all rights to such proprietary information as well as all rights under any such patent, none of which is waived by the submission of this instruction manual to anyone. The recipient, if a Government agency, acknowledges that this instruction book and the equipment described were pro
4、cured with Limited Rights to technical data as described in ASPR 9-203 (b). Copyright AVO MULTI-AMP Corporation, 1983, 1984, 1985, 1986, 1987, 1988, 1991, 1992 RadioFans.CN 收音机爱 好者资料库 Part 12510 Rev. 4 11/7/95 TABLE OF CONTENTS SECTION PAGE INTRODUCTION GENERAL DESCRIPTION.Bulletin SPECIFICATIONS.Bu
5、lletin SAFETY PRECAUTIONS. 1 THEORY OF OPERATION. 2 DESCRIPTION OF CONTROLS . 2 SELECTION OF OUTPUT TERMINAL. 5 OVERLOAD CAPACITY. 7 STORAGE AND OPERATION CONDITIONS . 8 TEST PROCEDURE. 9 TIME DELAY OF MOTOR OVERLOAD RELAYS. 9 INSTANTANEOUS ELEMENT OF MOTOR OVERLOAD RELAYS. 11 THERMAL ELEMENT OF MOL
6、DED CASE CIRCUIT BREAKERS . 13 INSTANTANEOUS ELEMENT OF MOLDED CASE CIRCUIT BREAKERS . 15 CIRCUIT BREAKER GROUND FAULT TRIP DEVICES . 17 OVERLOAD DEVICES MAINTENANCE DATA . 19 MAINTENANCE OF MOLDED CASE CIRCUIT BREAKERS. 19 MAINTENANCE OF MOTOR OVERLOAD RELAYS. 20 USING THE TEST RECORD SYSTEM. 22 SE
7、RVICE DATA. 22 SERVICING. 22 SERVICE AND REPAIR ORDER INSTRUCTIONS. 23 TABLE OF CONTENTS RadioFans.CN 收音机爱 好者资料库 Part 12510 Rev. 4 11/7/95 PREPARATION FOR RESHIPMENT. 24 WARRANTY STATEMENT. 25 OPERATIONAL ERRORS/TROUBLESHOOTING. 26 PARTS LIST. 28 INDEX. 29 SCHEMATIC DRAWING. 30 Part 12510 Rev. 4 11/
8、7/95 SAFETY PRECAUTIONS Every consideration has been given to the design and construction of the Multi-Amp Model MS- 2 Portable High Current Test Set to make it a safe piece of test equipment as well as one that is accurate, reliable, and easy to use. WARNING The Model MS-2 is not designed for use o
9、n energized circuits. For the safety of the operator and protection of the instrument, do not connect it to circuits that are energized. This includes circuits that could become energized during the course of a test procedure utilizing this instrument. It must be remembered that the test set is capa
10、ble of producing voltage and current levels that can be deadly if personnel come in contact with them. For safe operation, it is absolutely essential that the technician properly and effectively ground (earth) the test set. This is accomplished by connecting the input line cord to a properly grounde
11、d receptacle. CAUTION The input voltage of this instrument is not selectable. All the units are shipped from the factory set up for operation from either a nominal 115 volt or 230 volt source. If the unit is to be used on a voltage source different than the nameplate specifies, major changes in the
12、test set are required. It is necessary for the technician to contact the factory to obtain the necessary parts and instructions before attempting to change the input voltage of the test set. The MS-2 should be properly operated by qualified personnel who have familiarized themselves with the test se
13、t and thoroughly read the instruction manual provided with it. If questions arise concerning the care, operation, maintenance or application of the test set, contact the Multi-Amp Corporation for assistance. Part 12510 Rev. 4 11/7/95 THEORY OF OPERATION DESCRIPTION OF CONTROLS This section of the in
14、struction manual describes the functions of all the various control switches, etc. which are located on the control panel of the Model MS-2. All controls are clearly marked and logically grouped so that continual reference to the instruction manual should not be necessary after the operator has beco
15、me acquainted with the operation of the test set. For the location of the controls described in this section, see MS-2 Control Panel Figure #1. POWER ON/OFF Switch: Controls input power to the test set. The self-protected switch resets after an overload, when placed in the OFF position. Displays wil
16、l light when the switch is ON. MAIN FUSE: Protects power output circuit of MS-2 against overloads. CONTROL FUSE: Protects instrumentation and control circuitry against overloads. OUTPUT CONTROL: Variable autotransformer provides continuous non-stepped output from a variety of current-rated terminals
17、. Output system is controlled by a combination of timer STOP MODE and output mode switch positions. OUTPUT ON Lamp: Lights whenever output control circuit is energized. OUTPUT Terminals: A combination of the COMMON terminal and any one of the four current-designated terminals provides an output circ
18、uit. Refer to other sections of the text for an explanation of the output characteristics of these terminals. NOTE: The current designation of these terminals has no bearing on the actual current output capability of each. Much higher currents can be achieved depending on test circuit impedance and
19、duration of the test. Output Mode Switch: Initiates the output circuit in conjunction with the appropriate Timer STOP MODE Switch position. MOMENTARY Position: Momentary ON position with spring return to OFF. Output will remain energized as long as switch is held in MOMENTARY position and is de-ener
20、gized when released. Timer starts and stops in the same manner. Used for jogging the output circuit. Part 12510 Rev. 4 11/7/95 MAINTAIN Position: Maintained ON position with spring return to OFF. Output will remain energized until appropriate STOP MODE function occurs, switch is moved to OFF positio
21、n or current drops below threshold requirement. OFF Position: Test set input power remains energized but output current remains de-energized and timer will not count. AMMETER: LED displays show the numeral one in the left most position when the meter is over-ranged. RANGE SWITCH: Decimal of display