Biddle PMM-1_UG 电路图.pdf
《Biddle PMM-1_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle PMM-1_UG 电路图.pdf(67页珍藏版)》请在收音机爱好者资料库上搜索。
1、Part No. 17357 Rev. 5 Date 9/26/00 POWER MULTIMETER OPERATING AND INSTRUCTION MANUAL CAT. NO. PMM-1 It is essential that this instruction book be read thoroughly before putting the equipment in service! RadioFans.CN 收音机爱 好者资料库 REVISIONS HISTORY RevisionECN#Date 004/28/97 12756206/27/97 22804012/01/9
2、8 32851006/17/99 411/29/99 5288349/20/00 IMPORTANT The information and data contained within this instruction manual are proprietary with AVO International. The equipment described herein may be protected by one or more U.S. letters patent. AVO International specifically reserves to itself all right
3、s to such proprietary information as well as all rights under any such patent, none of which is waived by the submission of this instruction manual to anyone. The recipient, if a Government agency, acknowledges that this instruction book and the equipment described were procured with Limited Rights
4、to technical data as described in ASPR 9-203 (b). Copyright AVO International 1997, 1998, 1999, 2000 RadioFans.CN 收音机爱 好者资料库 i TABLE OF CONTENTS 1OPERATOR SAFETY. 1 1.1DESCRIPTION . 1 1.2EXPLANATION OF SAFETY SYMBOLS. 1 1.3GROUNDING. 2 1.4POWER CORD AND FUSES. 2 2GENERAL INFORMATION . 3 2.1DESCRIPTI
5、ON . 3 2.2APPLICATIONS. 3 2.3FEATURES.3 2.4ELECTRICAL SPECIFICATIONS. 5 2.5MECHANICAL AND ENVIRONMENTAL SPECIFICATIONS. 6 2.6ORDERING INFORMATION. 6 2.7CHANGES. 7 2.8WARRANTY. 7 3INSTALLATION. 9 3.1UNPACKING AND INSPECTION. 9 3.2PREPARATION FOR USE . 9 3.3REPACKING AND SHIPMENT. 9 4OPERATING INSTRUC
6、TIONS. 10 4.1PANEL CONTROLS AND OPERATING FUNCTIONS. 10 4.2SAFETY CONSIDERATIONS. 12 4.3USING THE INTERNAL BATTERY. 12 4.4GENERAL OPERATING INSTRUCTIONS. 14 4.5SINGLE PHASE OPERATION . 14 4.5.1SELECTING THE INPUT CHANNEL. 15 4.5.2THE MEASURING FUNCTIONS. 17 RadioFans.CN 收音机爱 好者资料库 ii 4.6THREE-PHASE
7、OPERATION . 18 4.6.1SELECTING THE CONFIGURATION . 18 4.6.2THE MEASURING FUNCTIONS. 20 4.7CLAMP-ON CURRENT AND POTENTIAL TRANSFORMER OPERATION . 21 4.7.1MEASURING PRIMARY CURRENT. 22 4.7.2VERIFYING THE RATIOS OF CTS. 23 4.8HIGH-SPEED SINGLE-PHASE CAPTURE MODE . 24 4.8.1THE MEASURING FUNCTIONS. 25 4.9
8、TIMER/RELAY OPERATION. 28 4.9.1MODES OF OPERATION. 28 4.9.2THE MEASURING FUNCTIONS. 29 4.10 VIEW SAVED DATA Directory. 30 4.11 TIMED DATA TRANSMISSION. 31 4.12 SETTING THE CLOCK AND DATE. 35 4.13 PERIPHERAL OPERATION. 35 4.13.1 PRINTER PORT. 35 TABLE 4-1DOT MATRIX PRINTER PORT PIN-OUT . 36 4.13.2 RS
9、232 SERIAL DATA PORT. 36 TABLE 4-2 RS232 CONNECTOR PIN-OUT . 37 POWER MULTIMETER COMMAND SET. 38 CALIBRATION PROCEDURES. 43 PMM-1 QUICK TIPS. 46 EXAMPLES .48 EXCEL PROGRAM INSTRUCTIONS. 56 5SERVICE AND MAINTENANCE . 63 1 1OPERATOR SAFETY ATTENTION: READ THIS MANUAL BEFORE PROCEEDING WITH INSTALLATIO
10、N AND OPERATING THE INSTRUMENT. 1.1DESCRIPTION This instrument must be operated, used and serviced ONLY by trained, qualified personnel. Misuse of electrical instruments can result in personal injury and damage to the apparatus under test. Obey all applicable safety rules and regulations at all time
11、s. Refer to the following sections of this manual for operating specifications and procedures. 1.2EXPLANATION OF SAFETY SYMBOLS AVO International uses, where applicable, the following IEC 417 symbols on its instruments: This symbol indicates that the operator of the instrument must refer to the inst
12、ruction manual for further explanation and clarification. ? ? ? ? ? Safety Ground Terminal. This terminal must be connected to an earth ground before making other connections to the instrument and prior to operating it! This red symbol indicates that high voltage (i.e., any voltage equal or greater
13、than 1000 Volts) is present on the terminal. Use extreme care. This is the symbol for a sinusoidal AC voltage or current. AC or DC voltage. 2 1.3GROUNDING Where a ground binding post or a grounding lead is provided on the instrument, it must be connected to an earth ground PRIOR to making any other
14、connections. WARNING: To avoid electric shock do not interrupt the connection to the protective safety ground. 1.4POWER CORD AND FUSES The power cord must be connected to a grounded supply system with proper electrical ratings, as indicated on the instrument. In the case of detachable power cords, o
15、nly the cord supplied or specified by AVO International should be used. WARNING: TO AVOID ELECTRIC SHOCK ALWAYS DISCONNECT THE POWER CORD FROM THE SUPPLY CIRCUIT BEFORE SERVICING THE INSTRUMENT OR WHEN REPLACING A FUSE. WARNING: ALL FUSES MUST BE REPLACED WITH THE SAME TYPE AND CURRENT AND VOLTAGE R
16、ATINGS. SHORT-CIRCUITING THE FUSEHOLDER IS PROHIBITED. 3 2GENERAL INFORMATION 2.1DESCRIPTION The AVO International POWER MULTIMETER (Model PMM-1) is a next generation portable battery/line operated multifunction instrument for measuring AC or DC voltage, AC primary and secondary current, power, reac
17、tive power, phase angle and frequency of a single or three phase electrical system. POWER MULTIMETER is easily configured to measure the amplitude and phase angle between any two voltage and current inputs. All measured quantities are displayed simultaneously on an easy-to-read graphic display. The
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle PMM-1_UG 电路图 PMM _UG
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf