Cal_field 电路图.pdf
《Cal_field 电路图.pdf》由会员分享,可在线阅读,更多相关《Cal_field 电路图.pdf(27页珍藏版)》请在收音机爱好者资料库上搜索。
1、Presentation of the paper at the Workshop: How to use TEM-devices in compliance EM-field testing EMV2000 Dsseldorf, 22.02-24.02.2000 All rights reserved to the authors. TEM Waveguides - Principles, Evaluation Criterions and Examples - Prof. Dr.-Ing. Heyno Garbe, Dipl.-Ing. Jens Peter Krst University
2、 of Hannover Appelstr. 9A D-30167 Hannover, Germany Tel.: +49 511 762 3760 Fax: +49 511 762 3917 e-mail: heyno.garbeieee.org 0Introduction The testing of electromagnetic interference presents, in general, enormous problems due to the very high costs involved in constructing and preparing test equipm
3、ent. Over the past years, investigations have been carried out as to how these very complex field tests could be carried out using simpler, less expensive equipment. Various new test installations have been proposed based upon far field measurements of an antenna. The aim of these installations was
4、to test the emission or interference resistance of a device under far field conditions as realistic as possible. TEM cells and other TEM wave guide constructions have already become part of todays standards. Well-enclosed housings no longer require expensive, shielded rooms. Therefore, a large requi
5、rement has evolved for this type of inexpensive test equipment. Recently, a lot of test facilities have been offered on the market as further possibilities for field measurements. They all claim to fulfil the function of TEM wave guides. The intention of this presentation is to investigate how it co
6、uld be determined whether they fulfil TEM wave conditions. This leads to definitions as presented in IEC 1000-4-3. This standard should appear as EN 61 000-4-3. The general definitions from the standard will be clarified to allow a comparison between the test devices. The proposed limits for field h
7、omogeneity and depolarisation angle are justified. Under these assumption TEM-, GTEM-, G-Strip and MAC-cells are tested. As a result the applicable frequency range for each test facility could be clearly identified. 1Antenna far field = TEM wave propagation As shown in 1 each given electromagnetic f
8、ield can be described as a superposition of well known wave types called field modes: L rrrr L rrrr += += 1010 1010 TMTETEM TMTETEM HHHH EEEE The term Txy stands for There is no component of the x- and y-field in longitudinal direction (=direction of wave propagation). There are only transverse comp
9、onents of x- and y-field. RadioFans.CN 收音机爱 好者资料库 WS: TEM Waveguides - Principles, Evaluation Criterions and Examples - Prof. Dr.-Ing. H. Garbe, 2000 Page 2 of 27 From this we can see that the TEM-wave doesnt have to have a longitudinal component. The ratio of TEM E r and TEM H r is given by = 120 0
10、 0 TEM TEM TEM H E r r for propagation in air. The propagation velocity of the TEM-mode is given by the material constant likewise: 0 00 1 ccTEM= = This is the well known speed of light. Identifying TEM-fields we have to look for the following criterions: 1. Only field components in the transverse p
11、lane 2. Ratio of the absolute value is given by 120 . 3. Propagation velocity is equal to c0. Another important aspect of the TEM mode is that it is independent of the radiator / antenna. After this scientific considerations lets have a look to real applications of field measurements. As proposed by
12、 IEC 1000-4-3 a typical test set-up is shown in figure 1. Fig. 1: Immunity measurement in an ALC (MAZ, Hamburg) Equipment under test Transmitting antenna RadioFans.CN 收音机爱 好者资料库 WS: TEM Waveguides - Principles, Evaluation Criterions and Examples - Prof. Dr.-Ing. H. Garbe, 2000 Page 3 of 27 An antenn
13、a illuminates the EuT for the frequency range from 10 - 1000 MHz. The distance between EuT and transmitting antenna has to be 3 m. It can be show that the radiated field far away from the antenna fulfils the TEM-mode criterions. the rule of thumb for the minimum distance is some what in the order of
14、 the used wavelength. For this case this isnt valid. The wavelength from 10 MHz requires a distance of 30 m. On the other hand a high field strength is needed at the EuT. So a compromise is found and the minimum distance is set to 3 m. Nevertheless TEM-mode conditions is assumed at the EuT. Concludi
15、ng this chapter we can say that we need a defined field mode (TEM mode) to ensure reproducible and well defined field measurements. If several test facilities have to be compared the main task is how the test site generates a pure TEM-field. 2Evaluation Criterions The calibration procedure for field
16、 immunity tests is shown in figure 2. Fig. 2: Field calibration according to IEC 1000-4-3 Various criterions which alternative test equipment must fulfil, can be extracted from the IEC 1000- 4-3 standard. They are presented briefly below: Field Homogeneity The IEC 1000-4-3 chap. 6.2 requires the fie
17、ld to be homogeneous over a surface in front of the test object. A surface perpendicular to the direction of the field propagation is selected. This square surface must be at least as large as the irradiated surface of the device under test (DUT), but not more than 1.5m RadioFans.CN 收音机爱 好者资料库 WS: T
18、EM Waveguides - Principles, Evaluation Criterions and Examples - Prof. Dr.-Ing. H. Garbe, 2000 Page 4 of 27 x 1.5m. The DUT is removed and the field strength measured at each of 16 equally distributed points. For at least 12 points, the difference between the minimum and maximum values must not exce
19、ed 6 dB. DUT field propagation 1.5 m 1.5 m min 0.8 m conducting surface Fig. 3:Definition of field homogeneity for irradiation test according to IEC 1000-4-3 The surface in which the field point are located must be as large as the irradiated surface of the DUT. The test points may not be situated on
20、 the conducting surface or under the DUT. A disadvantage of this procedure is that 25% of the measured values are not taken into account in any way. For this reason a new statistical approach was proposed in 4. Assuming a statistical distribution of the measured values the 6 dB criterion can be writ
21、ten as dB sx sx 6 15, 1 15, 1 log20 + + with:mean value = = n i i x n x 1 1 standard deviation() = = n i i xx n s 1 2 1 1 probability()15, 1%75=+kskxxskxp i To obtain the required homogeneity of the field strength at first the mean value and the standard deviation for the n=16 measured field values
22、have to be calculated. If sx sx + + 15, 1 15, 1 log20 is smaller than 6 dB the criterion is fulfilled. Figure 4 shows an example for the field homogeneity of a GTEM cell at 100 MHz. 51015202530 2.5 5 7.5 10 12.5 15 17.5 20logdB r r E E r E V m 0-1-2-3+3+2+1 ( )p E r % r Es + 115, r Es 115, r E Fig.
23、4: Field homogeneity of a GTEM cell WS: TEM Waveguides - Principles, Evaluation Criterions and Examples - Prof. Dr.-Ing. H. Garbe, 2000 Page 5 of 27 Defined field polarisation / TEM wave propagation ” This investigation shall be carried out separately for vertical and horizontal fields .” (IEC 801-
24、3/IEC 1000-4-3 chap. 7) At this point the observed field strengths must be differentiated. The total field strength is often viewed as EEEE gesxyz =+ 222 x y z r E l t Ez Ey Ex Polarisation direction Popagation direction Fig. 5: Definition of the field components On the other hand, the field strengt