Biddle S1_5001_UG 电路图.pdf
《Biddle S1_5001_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle S1_5001_UG 电路图.pdf(58页珍藏版)》请在收音机爱好者资料库上搜索。
1、M S1-5001 5kV Digital Insulation Tester User Guide Guide de lutilisateur Gebrauchsanleitung Gua del usuario RadioFans.CN 收音机爱 好者资料库 Symbols used on the instrument Caution: Refer to accompanying notes. Risk of electric shock. Equipment complies with relevant EU Directives Equipment protected througho
2、ut by Double Insulation (Class II). ContentsGuide de lutilisateur - p21Gebrauchsanleitung - s33Gua del usuario - p45 2 Safety Warnings 3 General Description 4 Test Mode Summary5 Features and Controls6 Battery Charging7 Operation Testing Precautions8 Performing Tests - General9 Testing procedures10 I
3、nsulation Resistance Testing (R)10 Test Current measurement (I)10 Fault Conditioning (BURN)10 Using the Guard Terminal11 Measurements above 100 G11 Condition and Warning Indicators12 Application Notes Preventive Maintenance13 Insulation Testing Concepts14 Stress considerations15 Specification 16 Acc
4、essories19 Repair and Warranty20 RadioFans.CN 收音机爱 好者资料库 3 SAFETY WARNINGS Safety Warnings and Testing Precautions must be read and understood before the instrument is used. They must be observed during use The circuit under test must be switched off, de-energised and isolated before test connection
5、s are made. The S1-5001 can generate up to 5 mA at 5000 V. Circuit connections must not be touched when HV is selected. Circuits must be discharged before disconnecting the test leads. In certain circumstances, break-down of the circuit under test may cause the instrument to terminate the test in an
6、 uncontrolled manner, possibly causing a loss of display while the circuit remains energised. In this event, it is important that the circuit is allowed to discharge and the instrument is turned off before touching any connections. The test terminal area and charging panel recess should be kept in a
7、 dry, clean condition. Replacement fuses must be of the correct type and rating. The instrument should not be used if any part of it is damaged. Refer to Testing Precautions on page 8 for further explanations and precautions. NOTE THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PE
8、RSONS. RadioFans.CN 收音机爱 好者资料库 Charging connections, mains power indicator and instrument protection fuses are located in a splashproof protected recess in the front panel. Specially designed lid hinges enable the lid to be removed and replaced as required, and will protect the lid from strain or da
9、mage by unclipping itself if unintentionally opened past its full extent. Design safety features include:- The flashing HV warning LED on the front of the instrument, and the flashing H.V. symbols on the display remind the user that hazardous voltage is present when testing. External voltage 50 V di
10、splayed with flashing H.V. symbols on the display. Load automatically discharged at the end of a test, and decaying voltage ( 50 V) displayed. Interlocked sliding cover to prevent simultaneous access of charging and test terminals. Test terminal sockets lock test leads into the case and prevent acci
11、dental disconnection. General Description 4 The S1-5001 is a compact, battery powered, high voltage d.c. insulation tester. The instrument is microprocessor controlled and features a large, clear LCD combining digital and analogue readings of insulation resistance.The digital full scale of 5 T can b
12、e set to display leakage current instead of resistance. In this mode of operation, higher resistances can be measured. The S1-5001 has selectable test voltage options of 500 V, 1000 V, 2500 V and 5000 V. A variable output voltage setting provides a range of 25 V to 5000 V incremental in 25 V steps.
13、At switch on, the instrument carries out a calibration self check which automatically adjusts the measurement system. The calibration sequence inhibits any testing if the measurement system fails to meet preset limits. On starting a test, the HV warning LED on the front of the instrument flashes, to
14、gether with the display HV warning symbols. The integral timer starts automatically and displays minutes and seconds elapsed since the start of the test. The timer can be used to set the duration of a test, and will automatically stop the output voltage when the set time has expired. Battery capacit
15、y is continuously displayed by a segmented indicator. The indicator flashes when the battery requires recharging. Power is obtained from two parallel connected sealed rechargeable lead acid batteries. If either battery fails (or an internal protection fuse ruptures) the instrument will continue to o
16、perate on the alternative battery. The battery is recharged by external 95 - 265V a.c., 50-60 Hz, or 12 V d.c.supply. Test Mode Summary 5 Insulation Resistance Testing (R) This mode measures insulation resistance at the selected voltage to provide an instantaneous spot reading. Final test result is
17、given sequentially with the corresponding leakage current and capacitance value. Test Current measurement (I) This mode measures insulation at the selected voltage to provide an instantaneous spot reading, but displays leakage current value on the digital display. (N.B. The analogue scale always dis
18、plays resistance). Final test result is given sequentially with the corresponding resistance and capacitance value. Fault Conditioning (Burn) This feature is used to carry out continuous testing under breakdown conditions. General Notes: 1) Acapacitance value reading is only available if the test ha
19、s run for more than one minute, and the reading was not over-range. 2) Internal discharge resistors are automatically selected :- -At the end of a test. -If the instrument is switched off. -If an internal error is detected. Any voltage remaining on the terminals at the end of a test,will be displaye
20、d until it has decayed to less than 50 V. During a test output terminal voltage is displayed, together with flashing high voltage symbols, and the flashing red LED. 6 Features and Controls IL ML M I R 1000V 00:30 1T 100G 10G 1G100M 10M 1M 0.1M 0 L M G Terminal Connection covers Individually lifted t
21、o access test lead terminals. Covers interlocked with sliding recess cover. Splashproof recess Cover Slides back to reveal mains and 12V battery charging connections together with instrument protection fuses. Voltage display Test voltage or external voltage 50V, together with flashing H.V. symbols.
22、Condition and Warning indicators Flash to indicate any adverse conditions affecting the test. Also indicates when results of last test are being sequentially displayed. Display right hand cursor Indicates selected Test mode. Display left hand cursor Indicates selected voltage, or the timer. Battery
23、capacity Indicator Segments recede as battery is used. Symbol flashes when battery charge is excessively low. Test Push Press for at least 1 second to initiate test and start Timer. Press again to manually stop test. Range Keys 1) Select test mode. 2) Adjust variable voltage. 3) Set timer. Max. 90 m
24、inutes. Selector Keys 1) Set voltage 2) Set Timer On/Off Button Press to turn On /Off. (Wait a few seconds for Automatic Calibration) Timer display - Shows set test duration and displays time elapsing during test. HV Warning - Flashes when a test is in progress or a General It is advisable to fully
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle S1_5001_UG 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


