BIRD 3129 BPM Broadcast Power Monitor and Display (2005) 电路图.pdf
《BIRD 3129 BPM Broadcast Power Monitor and Display (2005) 电路图.pdf》由会员分享,可在线阅读,更多相关《BIRD 3129 BPM Broadcast Power Monitor and Display (2005) 电路图.pdf(43页珍藏版)》请在收音机爱好者资料库上搜索。
1、INSTRUCTION BOOK BROADCAST POWER MONITOR SERIES BPM AND MODEL 3129 BPM DISPLAY Bird Electronic Corporation 30303 Aurora Road Cleveland (Solon), Ohio 44139 Sales i.e., from transmitter to antenna CAUTION The 3129 parallel port should only be used to power the BPM. Do not connect anything else to the
2、3129. WARNING Leaking RF energy is a potential health hazard. Never attempt to connect or disconnect equipment from the transmission line while RF power is being applied. Severe burns, electrical shock, or death can occur. Installation 13 “QC” Connector Use 50 ohm coaxial cable such as RG-218/U or -
3、220/U (-17A or -19A), appropriate for the frequency and power level of operation. Use a cable connector which will mate with the one on the BPM7. Swivel Flanged Connector To couple the swivel flange with a flanged RF transmission line, use an appropriate coupling kit. ?Insert the center bullet and p
4、ush it in until it is fully seated. ?Connect the coaxial input in a straight line and push carefully on the center conductor to close. ?NOTE: The swivel flange on the load makes connection independent of the orientation of the fixed flange on the coaxial input outer conductor. ?Insert the bolt sets
5、and tighten evenly all around to transmission line manufacturers recommended torque. Use all of the bolts. Unflanged Connector To couple the unflanged connector with an unflanged RF line, use an appropriate coupling kit. ?Insert the center bullet and bottom it on the midpoint nibs. ?Position the out
6、er sleeve, with clamping bands, over the input connector. ?Set the transmission line snugly against the coupling stops. ?Position the clamping bands evenly about 3/4” from the ends of the sleeve. ?Tighten the clamping bands. Figure 5 BPM Direction Bird BPM Series Broadcast Power Monitor 14 RS-232 Po
7、rt Setup The RS-232 port is configured for 9600 baud, 8 data bits, 1 stop bit and no parity. This configuration is fixed in the firmware and cannot be modified. Operate the serial interface as follows: ?Connect the BPM or BPM Display to the computers serial port with a DB-9 cable. Do not use a null
8、modem adapter. The port is configurable from within the PCTool software. ?To use the Bird PCTool software, install it on the computer and start the application. Refer to “PCTool Software” on page 16 for information about using the program. ?To use a terminal program, configure it for 9600 baud, 8 da
9、ta bits, 1 stop bit, no parity, and no handshake. Set the preferences so that echo is off and line feeds are not appended to output transmission. The commands available are detailed in “Terminal Commands” on page 20. PCTool Installation Computer Require- ments The Bird PCTool software will run on an
10、y computer running Windows NT or Windows 95/98/2000. To install and run the program, your computer system must meet or exceed the requirements listed below: 486 or better CPU (66 MHz or better recommended) 1 MB of free memory Hard Disk Drive CD-ROM Drive Follow the instructions on the CD provided to
11、 install the software. 15 Chapter 4Operating Instructions A description of all controls and indicators on the BPM, BPM Display, and PCTool is provided in this chapter. Read and become familiar with the following instructions before operating the unit. WarmupFor best results, allow the Bird Broadcast
12、 Power Monitor to stabilize for at least one hour after initially applying RF power, and for at least thirty minutes when adjusting power levels. ElementsBPM elements and line sections are carefully selected for accuracy. Use of BPM elements other than the ones on this unit may cause measurement err
13、ors. Do not remove the elements. BPM Controls There are two indicators and one control on the BPM: Operation/Test LED: Lights when the unit is powered. Alarm LED: Lights when an alarm has been triggered. Reset Switch: Press to reset an alarm. If the alarm trigger condition is still present, the alar
14、m will reactivate. Bird BPM Series Broadcast Power Monitor 16 PCTool Software Main ScreenThe PCTool communicates with and configures the remote BPM. It displays forward and reverse power along with VSWR, return loss, match efficiency and transmitted power. Figure 6 shows a sample of the display scre
15、en. Refer to the software “Help” file for specific instructions. The main screen has two buttons at the bottom, “Trigger” and “Continuous”. Clicking on these will trigger readings. “Trigger” will display a single reading, while “Continuous” will take a new reading every second. Figure 6 Sample Displ
16、ay Operating Instructions 17 Com Settings The PCTool software must be set to use the correct Com Port to communicate with the Antenna Monitor. The default is Com Port 1. To change the Com Port, select the correct one from the “ViewComm Port” menu, shown in Figure 7 below. Alarm Options Three alarms
17、can be configured from the software. All alarms are configured from the “ViewOptions” menu, shown in Figure 8 below. ?High VSWR: Calculated VSWR exceeds a setpoint. ?High Fwd Power: Measured power exceeds a setpoint. ?Low Forward Power: Measured power is less than a setpoint. ?NOTE: Some models are
18、not equipped with all alarm variations. Master Alarm Enable: allows the alarms to work. When this checkbox is unchecked, all alarms will be disabled. When it is checked, the VSWR alarm will automatically be enabled while “Alarm on Zero Power”, “High Power Alarm”, and “Low Power Alarm” will be on or
19、off depending on their checkboxes. Relay Energized on Alarm: The energized state of the relay can be set. When this checkbox is unchecked, the relay will be de-energized when an alarm is detected and energized when there is no alarm. With this setting, the alarm is fail-safe. When it is checked, the
20、 relay will be energized when an alarm is detected and de-energized when there is no alarm. Figure 7 Com Menu Bird BPM Series Broadcast Power Monitor 18 Latch Alarms: Sets whether the alarm will reset automatically in the absence of an alarm condition.When this checkbox is unchecked, if an alarm tri
21、gger is corrected the alarm will reset after a forty second delay. When it is checked, the alarm must be manually reset. Alarm at Power (Pwr) Up: At power up, before the instrument is ready to take measurements, the microcontroller resets the circuitry to the default condition and then performs inte
22、rnal initialization tasks (such as memory test, hardware setup, and reading EEPROM parameters). Check the Alarm at Pwr Up box to have the alarm relay set (enabled) during the microcontroller initialization time. This is Figure 8 Options Menu Operating Instructions 19 the default setting. Uncheck the
23、 Alarm at Pwr Up box to disable the alarm during the microcontroller initialization time. ?NOTE: When the Alarm at Pwr Up feature is disabled, the alarm relay may set for a few milliseconds during initialization. To avoid this, install the circuit shown below. VSWR Alarm: adjustable from 1.3 to 2.5
24、by increments of 0.1. To allow the VSWR alarm to trigger even at low forward power ( 2.5% of full scale power), check the “Alarm on Zero Power” checkbox. While the VSWR trip point can now be set to 2.5, the instrument cannot always measure VSWR above 1.9. This is due to the large amount of reflected
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BIRD 3129 BPM Broadcast Power Monitor and Display 2005 电路图 2005
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-199927.html



Marshall-9100-62-02-Schematic电路原理图.pdf