1、INSTRUCTION MANUAL SPECTRUM ANALYZERS MODELS 2165A 2620A 2625 2630 RadioFans.CN 收音机爱 好者资料库 2 TEST INSTRUMENT SAFETY Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be performed where exposed voltage is present. An electrical
2、 shock causing 10 milliamps of current to pass through the heart will stop most human heartbeats. Voltage as low as 35 volts dc or ac rms should be considered dangerous and hazardous since it can produce a lethal current under certain conditions. Higher voltages pose an even greater threat because s
3、uch voltage can more easily produce a lethal current. Your normal work habits should include all accepted practices to prevent contact with exposed high voltage, and to steer current away from your heart in case of accidental contact with a high voltage. You will significantly reduce the risk factor
4、 if you know and observe the following safety precautions: 5. Dont expose high voltage needlessly. Remove housings and covers only when necessary. Turn off equipment while making test connections in high- voltage circuits. Discharge high-voltage capacitors after removing power. 6. If possible, famil
5、iarize yourself with the equipment being tested and the location of its high voltage points. However, remember that high voltage may appear at unexpected points in defective equipment. 7. Use an insulated floor material or a large, insulated floor mat to stand on, and an insulated work surface on wh
6、ich to place equipment; and make certain such surfaces are not damp or wet. 8. Use the time proven “one hand in the pocket” technique while handling an instrument probe. Be particularly careful to avoid contacting a nearby metal object that could provide a good ground return path. 9. When testing ac
7、 powered equipment, remember that ac line voltage is usually present on some power input circuits such as the on-off switch, fuses, power transformer, etc. any time the equipment is connected to an ac outlet, even if the equipment is turned off. 1. Some equipment with a two-wire ac power cord, inclu
8、ding some with polarized power plugs, is the “hot chassis” type. This includes most recent television receivers and audio equipment. A plastic or wooden cabinet insulates the chassis to protect the customer. When the cabinet is removed for servicing, a serious shock hazard exists if the chassis is t
9、ouched. Not only does this present a dangerous shock hazard, but damage to test instruments or the equipment under test may result from connecting the ground lead of most test instruments to a “hot chassis”. To test “hot chassis” equipment, always connect an isolation transformer between the ac outl
10、et and the equipment under test. The B+K Precision Model TR-110 Isolation Transformer, or Model 1653A or 1655A AC Power Supply is suitable for most applications. To be on the safe side, treat all two-wire ac equipment as “hot-chassis” unless you are sure it has an isolated chassis or an earth ground
11、 chassis. 2. On test instruments or any equipment with a 3-wire ac power plug, use only a 3-wire outlet. This is a safety feature to keep the housing or other exposed elements at earth ground. 3. B+K Precision products are not authorized for use in any application involving direct contact between ou
12、r product and the human body, or for use as a critical component in a life support device or system. Here, “direct contact” refers to any connection from or to our equipment via any cabling or switching means. A “critical component” is any component of a life support device or system whose failure t
13、o perform can be reasonably expected to cause failure of that device or system, or to affect its safety or effectiveness. 4. Never work alone. Someone should be nearby to render aid if necessary. Training in CPR (cardio- pulmonary resuscitation) first aid is highly recommended. RadioFans.CN 收音机爱 好者资
14、料库 3 Instruction Manual for Models 2615A, 2620A, 2625, 2630 SPECTRUM ANALYZERS RadioFans.CN 收音机爱 好者资料库 4 TABLE OF CONTENTS Page TEST INSTRUMENT SAFETY .Inside front cover SPECIFICATIONS.5 OPTIONAL ACCESSORIES .6 GENERAL INFORMATION.7 Symbols .7 Tilt handle.7 Safety.7 Operating Conditions.8 Maintenan
15、ce.8 Selecting the Line Voltage.8 INTRODUCTION.9 General .9 Operating Considerations .9 CONTROLS AND INDICATORS.10 CALIBRATION.15 Vertical Calibration.15 Horizontal Calibration.15 Page INTRODUCTION TO SPECTRUM ANALYSIS. 17 General . 17 Types of Spectrum Analyzers. 17 Spectrum Analyzer Requirements.
16、18 Frequency Measurements . 18 Resolution. 18 Sensitivity. 19 Video Filtering. 19 Spectrum Analyzer Sensitivity. 19 Frequency Response. 20 Tracking Generators. 20 APPENDIXdBm CONVERSION . 22 CUSTOMER SUPPORT. 23 INSTRUMENT REPAIR SERVICE . 23 WARRANTY SERVICE INSTRUCTIONS. 24 LIMITED ONE-YEAR WARRAN
17、TY. 25 5 SPECIFICATIONS NOTE: Specifications and information are subject to change without notice. Please visit for the most current product information. Frequency Frequency range: 0.15 MHz to 1050 MHz (3 dB) (Models 2625 and 2630) 0.15 MHz to 500 MHz (3 dB) (Models 2615A and 2620A) Center frequency
18、 display accuracy: 100 kHz Marker accuracy: (0.1% span + 100 kHz) Frequency display resolution: 100 kHz (4 digit LED for Models 2625 and 2630) (4 digit LED for Models 2615A and 2620A) Frequency scanwidth: 100 kHz/div. to 100 MHz/div. (Models 2625 and 2630) in 1-2-5 steps and 0 Hz/div. (Zero Scan) 50
19、 kHz/div. to 50 MHz/div. (Models 2615A and 2620A) in 1-2-5 steps and 0 Hz/div. (Zero Scan) Frequency scanwidth accuracy: 10% Frequency stability: Drift: 150 kHz / hour IF-Bandwidth (3 dB): Resolution: 400 kHz and 20 kHz (Models 2625 and 2630) Resolution: 250 kHz and 20 kHz (Models 2615A and 2620A) V
20、ideo-Filter on: 4 kHz Sweep rate: 43 Hz Amplitude Amplitude range: 100 dBm to +13 dBm Screen display range: 80 dB (10 dB / div.) Reference level: 27 dBm to +13 dBm (in 10 dB steps) Reference level accuracy: 2 dB Average noise level: 99 dBm (20 kHz BW) (Models 2625 and 2630) 99 dBm (20 kHz BW) (Model
21、s 2615A and 2620A) Distortion: 3 MHz apart) Sensitivity: dB above average noise level Log scale fidelity: 2 dB (without attn.) Ref.: 250 MHz IF gain: 10 dB adjustment range Input Input impedance: 50? Input connector: BNC Input attenuator: 0 to 40 dB (4 x 10 dB steps) Input attenuator accuracy: 1 dB/