BIRD 782-BGC 电路图.pdf
《BIRD 782-BGC 电路图.pdf》由会员分享,可在线阅读,更多相关《BIRD 782-BGC 电路图.pdf(56页珍藏版)》请在收音机爱好者资料库上搜索。
1、General Catalog A4454.qxd 10/1/07 1:29 PM Page 2 RadioFans.CN 收音机爱 好者资料库 Table of Contents 1BirdElectronic Corporation 1-866-695-4569www.bird- TABLE OF CONTENTS Spectrum Analysis SignalHawk SH-36S .3-4 Antenna and Cable Testing Site Analyzer6000EX.5-6 Site Analyzer2500EX.5-6 Site Analyzer1700EX and
2、1700EXP.5-6 Antenna and Cable Monitor.7 Antenna Testers .7 Laboratory Grade Instruments Calibration Cart.8 Dual Sensor internal Pre-Amplifier+24 dB gain, internal FREQUENCY Range 100 kHz to 3.6 GHz Resolution 1 Hz Uncertainty 1ppm Temperature Drift 1ppm/C Reference Aging 1ppm/year SPECTRAL PURITY 30
3、 kHz from carrier-85 dBc / (RBW Hz)1/2 100 kHz from carrier-100 dBc / (RBW Hz)1/2 100 kHz from carrier-124 dBc / (RBW Hz)1/2 BANDWIDTH Resolution100 Hz - 1 MHz in 1,3,10 steps Video 10 Hz - 1 MHz in 1,3,10 steps AMPLITUDE Measurement Range-135 dBm to +20 dBm Dynamic Range 66 dB, intermod-free Noise
4、Floor -135 dBm DANL Inherernt Spurious-80 dBm Input Related Spurious-70 dBc Amplitude Accuracy 1.0 dB typ, 1.5 dB max DISPLAY Screen8.4”, SVGA, indoor/outdoor Reference Level-140 dBm to +30 dBm, User selectable or autoscale Resolution800 x 600 pixels UnitsdBm, W, mW,W, dBV, dBmV, dBV, V, mV,V, db/m2
5、, V/m2 Offset Range-99 to 99 dB Data Points705 displayed Sweep Time2 s, full span; 1 ms, zero span TRIGGER SourcesInternal, external TTL, internal video ConnectorBNC(F) A4454.qxd 10/1/07 1:29 PM Page 3 Text Here www.bird- 1-866-695-4569 BirdElectronic Corporation 4 SignalHawk Spectrum Analyzer Stand
6、ard Accessories Model 5010B Directional Power Sensor Model 5011 Terminating Power Sensor MODEL 5012 5010B 5011 5A2720-2 5A2745-1 50-A-MFN-30 10-A-MFN-30 2-A-MFN-20 100-SA-MFN-40 25-A-MFN-30 5-A-MFN-20 TC-MNFN-1.5 TC-MNFN-3.0 TC-MNMN-1.5 TC-MNMN-3.0 TC-MNFE-1.5 TC-MNFE-3.0 TC-MNME-1.5 TC-MNME-3.0 PA-
7、MNME PA-FNME PA-MNFE PA-FNFE 4240-550 4240-500-1 4240-500-2 4240-500-10 ANT-100* ANT-400* ANT-800* ANT-900* ANT-1800* ANT-1900* ANT-2400* 7002C870 USB-Mouse USB-HUB STANDARD ACCESSORIES Soft Carrying Case, Quick Start Manual, PC Tool Software CD, Serial Cable, USB Cable, USB Drive,AC Power Supply,Au
8、tomotivePower Adapter, Headphones, Connector Cover SignalHawkT M WIDEBAND POWER SENSOR (MODEL 5012) (See page 13) Wideband Power Sensor, 350 MHz to 4 GHz, 150 mW to 150 W Avg, 400 W Peak. Measures forward and reflected average,VSWR, return loss (dB), peak, burst average, crest factor and CCDF. Forwa
9、rd average power accu- racy is 4% (0.2 dB). DIRECTIONAL POWER SENSOR (MODEL 5010B) (See page 16) Directional Power Sensor, 2 to 2700 MHz, 100 mW to 10 kW, requires ele- ments. Measures forward and reflected average,VSWR, return loss (dB), and peak. Forward average power accuracy is 5% (0.2 dB). TERM
10、INATING POWER SENSOR (MODEL 5011) (See page 14) Terminating Power Sensor, 40 MHz to 4 GHz, 10W to 10 mW (-20 dBm to +10 dBm). Measures forward average power.Accuracy is 5% (0.2 dB). TERMINATING POWER SENSOR (MODEL 5011-EF) (See page 14) Terminating Power Sensor, 40 MHz to 12 GHz, 10W to 10 mW (-20 t
11、o +10 dBm) Measures forward average power.Accuracy is 5% (0.2 dB). Model 5012 Wideband Power Sensor POWER METER OPTION Data Logging Optional Power Sensors: 5012, 5010B, 5011 Wideband 5012: 350 MHz to 4 GHz, 150 mW to 150 W average, 400 W peak, Forward Directional 5010B: 450 kHz to 2.7 GHz, 100 mW to
12、 10 kW, Forward and Reflected Terminating 5011: 40 MHz to 4 GHz, 10 uW to 10 mW, 50 W Attenuator Option DESCRIPTION Wideband Power Sensor Directional Power Sensor Terminating Power Sensor Replacement Battery Replacement USB Drive-WinCE compatible Attenuator, 50 W, 30 dB, N(M)/N(F) Attenuator, 10 W,
13、30 dB, N(M)/N(F) Attenuator, 2 W, 20 dB, N(M)/N(F) Attenuator, 100 W, 40 dB, N(M)/N(F) Attenuator, 25 W, 30 dB, N(M)/N(F) Attenuator, 5 W, 20 dB, N(M)/N(F) Test Cable, 1.5 m, N(M)/N(F) Test Cable, 3.0 m, N(M)/N(F) Test Cable, 1.5 m, N(M)/N(M) Test Cable, 3.0 m, N(M)/N(M) Test Cable, 1.5 m, N(M)/DIN(
14、F) Test Cable, 3.0 m, N(M)/DIN(F) Test Cable, 1.5 m, N(M)/DIN(M) Test Cable, 3.0 m, N(M)/DIN(M) Adapter, N(M)/DIN(M) Adapter, N(F)/DIN(M) Adapter, N(M)/DIN(F) Adapter, N(F)/DIN(F) Adapter Kit, 7/16 DIN Adapter, N(F)/N(F) Adapter, N(M)/N(M) Adapter, N(M)/SMA(F) Field Strength Antenna, 136 to 221MHz,
15、SMA(M) Field Strength Antenna, 400 to 512MHz, SMA(M) Field Strength Antenna, 824 to 894MHz, SMA(M) Field Strength Antenna, 890 to 960MHz, SMA(M) Field Strength Antenna, 1710 to 1880MHz, SMA(M) Field Strength Antenna, 1850 to 1990MHz, SMA(M) Field Strength Antenna, 2400 to 2500MHz, SMA(M) Hard Transi
16、t Case USB Mouse, Portable, Optical USB HUB, 4 Port, Ultra Mini OPTIONAL ACCESSORIES * Note:Adapter 4240-500-10 required for field strength antenna. A4454.qxd 10/1/07 1:29 PM Page 4 Antenna and Cable Testing 5BirdElectronic Corporation 1-866-695-4569www.bird- Model SA-6000EX, Model SA-2500EX, Model
17、SA-1700EX (475 points)/3.5 seconds; (949 points)/6 seconds Trace Resolution238 (default), 475, or 949 per trace data points Storage Capacity15 Set-Ups/(500) 238 point traces Immunity to Rejects on-frequency signals up to +13 dBm Interfering Signals Maximum Input Signal+22 dBm Data Transfer9-pin RS-2
18、32 (DB9), compatible with serial port InternalRechargeable Lithium-Ion batteries. 3-hour minimum operating time.Auto shut-off conserves battery life. External DC9 to 16 VDC fused, 3A External AC90 to 264 VAC 45-66 Hz; AC/DC adapter required Operating Temperature-10C to 50C (14F to 122F) Storage Temp
19、erature-40C to 80C (-40F to 176F) Humidity95% 5% max., (non-condensing) AltitudeUp to 15,000 feet (4572 m) Dimensions10.5 x 8.4 x 3.3 (265 mm x 212 mm x 83 mm) Weight5.5 lbs. (2.5 kg) UpgradeableNoYes, SA-6000EXYes SA-6000EXYes, SA-6000EX Model SA-6000EX Site Analyzer Model SA-1700EX Site Analyzer S
20、ite Analyzer SITE ANALYZERSERIES MODEL SA-6000EX (25 - 6000 MHz), MODEL SA-2500EX (780 - 2500 MHz), MODEL SA-1700EX (25 - 1700 MHz), MODEL SA-1700EXP (25 - 1700 MHz) ONE UNIT covers the entire 25-6000 MHz range! Easy to operate and field ready for first-time, occasional and experienced users. Suitab
21、le for use in Worldwide Cellular and PCS/DCS; supporting measurement of CDMA, GSM,TDMA and AMPS modulation schemes. Other applications include 3G, Broadcast, Government,Tactical Military, Microwave, Paging, Public Safety,Trunking,WLAN and WLL, and TETRA (see model matrix). Color display is clearly v
22、isible in direct sunlight WIth a single download you can view as Distance to Fault or Measurement Match-no need to store two traces. FDR (Frequency Domain Relectrometry) measurement method results in a highly reliable assessment of the health of critical components in your system; ultimately providi
23、ng a “heads-up” before a failure occurs. Fault location or DTF mode indicates VSWR or Return Loss levels at each point along the cable and antenna system length. Cable Loss function measures insertion loss of the cable system over a given frequency range. BirdsSite Analyzeris the user-friendly test
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BIRD 782-BGC 电路图 782 BGC
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
18WXST2.rar


