1、Model 8540 60V/30A/150W DC Electronic Load INSTRUCTION MANUAL Model 8540 RadioFans.CN 收音机爱 好者资料库 Safety Regulations To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. To avoid injuries, always disconnect power, discharge circuits, and remove external vol
2、tage sources before touching components. KEEP AWAY FROM LIVE CIRCUITS. We cannot accept responsibility for any direct or indirect financial damage or loss of profit that might occur when using the electronic load. The instrument chassis and cover must be connected to an electrical ground. WARNING We
3、 certify that this product met its published specifications at time of shipment from the factory. Certification Notice The information contained in this document is subject to change without notice. Please consult the B&K Precision website for the latest version. RadioFans.CN 收音机爱 好者资料库 Compliance S
4、tatements This product is subject to Directive 2002/96/EC of the European Parliament and the Council of the European Union on waste electrical and electronic equipment (WEEE) , and in jurisdictions adopting that Directive, is marked as being put on the market after August 13, 2005, and should not be
5、 disposed of as unsorted municipal waste. Please utilize your local WEEE collection facilities in the disposition of this product and otherwise observe all applicable requirements. Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with s
6、eparate collection systems) Connect it to safety earth ground using the wire recommended in the users manual. High voltage danger The symbol on an instrument indicates that the user should refer to the operating instructions located in the manual. Safety Symbols RadioFans.CN 收音机爱 好者资料库 Unpacking the
7、 instrument This instrument was carefully inspected before shipment. Upon receipt, inspect the instrument for damage that might have occurred in transit. If any sign of damage is found, notify your B&K Precision distributor. Check the list of supplied items Verify that you have received the followin
8、g items with your power supply. If anything is missing, contact your authorized B&K Precision distributor. - Power cord - Instruction manual Power Requirements The 8540 can operate on 110V AC or 220V AC. Before connecting the power cord to an AC outlet, make sure the voltage selector in the rear is
9、set to the correct line voltage. If necessary, replace fuses according to the table below. The instrument power fuse is located in a fuse compartment below the AC input receptacle. To access the fuse, first disconnect the power cord and then remove the fuse cartridge. Power-on procedure Turn on the
10、instrument by pressing the main power switch on the front panel of the unit. The instrument will automatically revert to the last setting before the power was turned off. Check out T0 250 mA, 250V198 V to 242 V220V AC T0 500 mA, 250V99 V to 121 V110V AC FuseRangeLine voltage The 9 pin D-sub connecto
11、r in the rear is for factory use only! This instrument does not offer a remote control interface. Note About the 8540 The B&K Precision 8540 DC electronic load (60V/30A/150W) can sink DC current in constant current, constant voltage, and constant resistance modes. Measured values have 10 mV and 1 mA
12、 resolution. Shorts can be simulated. Storage is provided for up to 100 groups, with 4 instrument setups per group. The instrument is easy to use and will find many uses for testing DC power supplies, batteries, and DC to DC converters. Full digital control 1mV /1mA measurement resolution Compact si
13、ze Bright, readable LED display Operating modes: CC/CV/CR Input on/off control High reliability due to OCP/OVP (over current, over voltage) protection Storage for 100 groups, 4 setups each Easy operation Features Constant Resistance (CR) mode In CR mode, the DC load will sink a current linearly prop
14、ortional to the voltage at the terminals. Constant V I Constant resistance Constant Current (CC) mode V I ConstantCurrent CC 時 , 為幾伏特,ITECH 吸取電 V Constant current I In CC mode, the DC load draws a constant current regardless of the voltage on its terminals. V I Constant voltage I I Constant Voltage
15、(CV) mode In CV mode, the DC load will draw enough current to keep the voltage at the terminals constant. 3/30A selector(shift) Shift button Main power on/off Air flow input Input on/off button Switch + memory C Left arrow + memory A Memory save (shift) Current or power value Step D + memory D Step
16、C + memory C Step A + memory A Step B + memory B Voltage or preset current, voltage or resistance value CV mode indicator Short indicator CC mode indicator CR mode indicator Recall indicator 30A mode selector indicator Shift indicator Input off indicator Right arrow + memory B Rotary encoder Input +
17、 Input - Recall (shift) Function setup (shift) Mode selector + memory D Voltage display indicator Current display indicator Setup indicator Short on/off Panel layout Power display indicator Quick Start Set the line voltage selector on the back panel to your local line voltage (110 VAC or 220 VAC). T
18、hen connect the power cord to the DC load and a wall power socket. Turn on the power to the DC load by pressing the 1 on the power switch. Set value Press thekey to turn on the CC LED. The load is now in CC mode. Set the current value by pressing the or keys to select the digit to adjust, then turn
19、the knob to change its value. After setting the current value, press the key to turn the load on. Constant Current Mode A AB B ModeDModeD On/OffOn/Off Press thekey to turn on the CV LED. The load is now in CV mode. Set the voltage value by pressing the or keys to select the digit to adjust, then tur
20、n the knob to change its value. After setting the voltage value, press the key to turn the load on. Constant Voltage Mode A A B B ModeDModeD On/OffOn/Off Press the key to turn on the CR LED. The load is now in CR mode. Set the resistance value by pressing the or keys to select the digit to adjust, t
21、hen turn the knob. After setting the voltage value, press the key to turn the load on. Constant Resistance Mode B BA A ModeDModeD On/OffOn/Off Set value Indicates which digit to adjust RecallCC ShortCV OFFShift 30ACR ABCD Set V W A 150W DC Electronic Load 8540 Indicates which digit to adjust RecallC
22、C ShortCV OFFShift 30ACR ABCD Set V W A 150W DC Electronic Load 8540 RecallCC ShortCV OFFShift 30ACR ABCD Set V W A 150W DC Electronic Load 8540 The input of the electronic load will be turned off automatically if the OCP value is lower than the actual current value. The default OCP setting is 30 A.
23、 NOTE OCP function Press the key, then press the key. The display will show OCP (Over Current Protection). This is the maximum current that will be allowed. Use the and keys and the knob to set the value. ShiftShift A A B B ViewC Change the displayed values The electronic load usually displays the a