Biddle 220003_UG 电路图.pdf
《Biddle 220003_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle 220003_UG 电路图.pdf(14页珍藏版)》请在收音机爱好者资料库上搜索。
1、AVTM220003 Rev. B January 2003 Instruction Manual AVTM220003 for DC A Strip Chart Recorder Catalog Nos. 220003 and 220003-47 PO Box 9007 Valley Forge, PA 19485-1007 U.S.A. 610-676-8500 Shipping Address: Valley Forge Corporate Center 2621 Van Buren Avenue Norristown, PA 19403 U.S.A. RadioFans.CN 收音机爱
2、 好者资料库 DC A Strip Chart Recorder Instruction Manual Copyright 1997 by Megger. All rights reserved. Reproduction without written permission is prohibited. Specifications are subject to change without notice. RadioFans.CN 收音机爱 好者资料库 AVTM220003 Rev. B (01/2003) i Table of Content 1 Introduction. 1 Rece
3、iving Instructions. 1 General Information. 1 2 Safety. 2 3 Specifications. 3 Dimensions and Weight. 3 Controls and Connectors. 3 Recorder. 4 4 Operation. 5 Paper Installation. 5 Operation Procedure. 6 5 Maintenance. 8 Routine Maintenance. 8 Calibration. 8 Troubleshooting and Repair. 9 Warranty.11 Ra
4、dioFans.CN 收音机爱 好者资料库 AVTM220003 Rev. B (01/2003) 1 Section 1 Introduction Receiving Instructions Check the equipment received against the packing list to ensure that all materials are present. Notify Megger of any shortage. Telephone (610) 676-8500. Examine the instrument for possible damage receiv
5、ed in transit. If any damage is discovered, file a claim with the carrier at once and notify Megger or its nearest authorized sales representative, giving a detailed description of the damage. This instrument has been thoroughly tested and inspected to meet rigid specifications before being shipped.
6、 It is ready for use when set up as indicated in this manual. General Information The Megger Strip Chart Recorder is an accessory designed for use with the Megger DC Dielectric Test Sets. It makes permanent records of quantities of dc current which appear in the test circuit when a specimen is energ
7、ized by the Dielectric Test Set. The recorder is packaged in a carrying case with a hinged lid that provides storage space for the power cord and instrument cable. All controls necessary for operating the recorder are contained in the unit. Connection to the current circuit of the Dielectric Test Se
8、t is made by plugging the instrument cable of the recorder into the external instrument jack of the test set. A 120 V (220003) or 240 V (220003-47) ac outlet is required to energize the chart drive of the recorder. AVTM220003 Rev. B (01/2003) 2 Section 2 Safety This instrument and the recommended op
9、erating procedures have been designed with careful attention to safety. Megger has made formal safety reviews of the initial design and any subsequent changes. Regardless of these efforts, it is not possible to eliminate all hazards from electrical test equipment. For this reason, every effort has b
10、een made to point out in this instruction manual the proper procedures and precautions to be followed by the user in operating the equipment. However, it is not possible to foresee every possible hazard which may occur. It is therefore essential that the user carefully consider all safety aspects of
11、 the test before proceeding. The following general guidelines apply to all operating and service personnel. The strip chart recorder is not in itself a source of high electrical energy; however, because it is connected to such a source, the same precautions apply. Refer to the Safety section of the
12、Dielectric Test Set manual for explicit safety instructions. ? Safety is the responsibility of the user. ? Misuse of this equipment can be extremely dangerous. ? Do not use this equipment or its accessories for any purpose other than that described in this manual. ? Refer fuse replacement to qualifi
13、ed personnel only. To avoid electric shock and fire hazard, use only the specified fuse, which is identical in type, voltage rating, and current rating. Warning Never insert or remove the input plug of the recorder from the EXTERNAL INSTRUMENT JACK of the Dielectric Test Set while the test set is en
14、ergized. To do so may present a shock hazard to the operator or cause damage to the test set. AVTM220003 Rev. B (01/2003) 3 Section 3 Specifications Dimensions and Weight Overall: 9 x 7-1/2 x 7-1/2 x 7-1/2 in. (23 x 19 x 19 cm) (L x W x H); 5.5 lb (2.5 kg) Recorder only: 3-5/8 x 5-5/8 x 4-5/8 in.; 3
15、-1/2 lb Controls and Connectors Range Switch This toggle switch can be set to 50 A, 500 A, or SHORT. When set to SHORT, the recorder system is protected against damage from physical shock and transient voltages. Use this switch position when setting the recorder zero. POWER Switch and Indicator When
16、 set to ON, this toggle switch energizes the recorder chart drive motor. The indicator, when lit, shows that voltage is present. Input Cable This cable, which stores in the lid of the carrying case, connects the recorder to the Dielectric Test Set by plugging into the EXTERNAL INSTRUMENT JACK of the
17、 test set. Power Cord This 7-1/2 ft molded plug and receptacle can be removed from the panel socket and stored in the lid of the carrying case. Fuse 0.50 A, type AGC, replaceable by removing the fuse holder cap (220003). 0.25 A, type AGC, replaceable by removing the fuse holder cap (220003-47). AVTM
18、220003 Rev. B (01/2003) 4 Recorder Accuracy: 2% of full scale Response time: 1 second full scale Recording rate: 1 dot per 2 seconds Chart type: pressure-sensitive paper Chart speed: 60 in./hr Chart overall width: 2-9/16 in. (1/64) Chart analog span: 2-1/8 in. wide Chart length: 62 ft a roll Power r
19、equirements: 120 V, 60 Hz 10% (220003) 240 V, 50 Hz 10% (220003-47) AVTM220003 Rev. B (01/2003) 5 Section 4 Operation Paper Installation Either of two methods can be used to handle the recorded portion of the chart. The Reroll method routes the chart paper onto a roller for storage or review at a la
20、ter time. The Feed-Through/Tear-Off method routes the chart paper upward through the top of the door so that it may be easily reviewed during recording or, if desired, torn from the rest of the chart. Reroll Method 1. Remove signal and power inputs so that stylus is in its zero position and non- act
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle 220003_UG 电路图 220003 _UG
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


