1、 USER MANUAL 8500 SERIES DC ELECTRONIC LOADS Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524 to stop the short, you must press the On/Off key Note: When emulating a Short while in CV mode, the current software limit may trigger the DC load Input to turn Off, provided the current limit is
2、 reached. This does not affect the programmed settings and the DC load will restore the previously programmed values once the Short condition is removed. Battery test The battery test feature measures the time it takes for a battery voltage to drop to a specified value while drawing a constant curre
3、nt from the battery. When the voltage at the DC Loads terminals reaches the specified voltage, the test is ended and the integrated current (i.e., charge supplied by 8500 DC Load Series Version: February 4, 2009 Page 32 of 76 the battery) in ampere*hours (A*hrs) of the battery is calculated and disp
4、layed. To run a battery test, follow these steps: Key pressesDisplay I-set, enter current value with numerical keys, then press Enter. Set the DC Load to constant current mode and set the current you want to draw from the battery. (You may have to press the I-set key twice to be able to set the curr
5、ent value.) Shift + BatteryMIN VOLT= 0.10V This indicates youre being asked for the voltage level where the battery test will be over. Enter voltage level and press Enter. When you press Enter, the test will start. The CC annunciator will be on. or Shows the power level and the ampere*hours (A*hrs)
6、accumulated so far. When the battery voltage drops below the specified value, the test will turn off and you will see the OFF annunciator. or Display the total charge delivered by the battery in ampere*hours (A*hrs). Shift + BatteryTurns battery testing mode off. NOTE: you must make sure that you pr
7、ess Shift + Battery at the end of the test. Otherwise, the instrument will not respond to any key presses except or . Transient operation The transient condition allows switching between two different load values. There are three different types of transient operation. Continuous transient operation
8、 In continuous transient operation, the load is continuously switched between two load values. An example is shown in the following figure: 10A 5A Continuous Transient Operation 2.0ms3.0ms Note that this transient behavior works with any of the operation modes CC, CV, CW, or CR. Here are the keystro
9、kes used to setup this continuous transient condition: KeysDisplay I-setStandard display of voltage and current (or, youll be asked to enter a current value). 8500 DC Load Series Version: February 4, 2009 Page 33 of 76 KeysDisplay Shift + S-TranLEVEL A= X.XXXA You are being prompted for the first cu
10、rrent value. Press the 5 key for 5 A. EnterEnters the 5 A value, then displays WIDTH A = X.XMS. Youre being prompted for the duration of the 5 A load - press the 3 key for 3 ms. EnterEnters the 3 ms value, then displays LEVEL B= X.XXXA. You are being prompted for the second current value. Press the
11、1 and 0 keys to enter 10 A. EnterEnters the 10 A value, then displays WIDTH B = X.XMS. Youre being prompted for the duration of the 10 A load - press the 2 key for 2 ms. EnterEnters the 2 ms duration, then displays :CONTINUOUS, :PULSE, or :TOGGLED. Use the or arrow keys to display :CONTINUOUS. Enter
12、Returns to the standard display of voltage and current. To activate this continuous transient condition, press Shift + Tran, then press On/Off. The load will begin switching between the two Tran values with the timing you entered. Pulse transient operation In pulse transient operation, the load oper
13、ates at the A value that has been entered until a trigger is received. At the trigger, the load switches to the B value and stays at that level for the B timing value. Then the load switches back to the A value and stays there until another trigger is received. Heres an example: 10A 5A Pulsed Transi
14、ent Operation 10ms TWD 10ms TWD TRIGTRIG Here are the keystrokes needed to set up this example: KeysDisplay I-setStandard display of voltage and current (or, youll be asked to enter a current value). Shift + S-TranLEVEL A= X.XXXA You are being prompted for the first current value. Press the 5 key fo
15、r 5 A. EnterEnters the 5 A value, then displays WIDTH A = X.XMS. Youre being prompted for the duration of the 5 A load. In the pulse mode of operation, this width is ignored, so enter any convenient value. EnterDisplays LEVEL B= X.XXXA. You are being prompted for the second 8500 DC Load Series Versi
16、on: February 4, 2009 Page 34 of 76 KeysDisplay current value. Press the 1 and 0 keys to enter 10 A. EnterEnters the 10 A value, then displays WIDTH B = X.XMS. Youre being prompted for the duration of the 10 A load - press the 1 and 0 key for 10 ms. EnterEnters the 10 ms duration, then displays :CONT
17、INUOUS, :PULSE, or :TOGGLED. Use the or arrow keys to display :PULSE. EnterReturns to the standard display of voltage and current. To activate this pulse transient condition, press Shift + Tran, then press On/Off. The load will start at the A level of current you entered (5 A). Press Shift + Trigger
18、 to cause the load to switch to the B level of current (10 A). The 10 A current will last for the designated 10 ms, then switch back to the A level (5 A). NOTE: This example requires the :CONFIG:TRIGGER menu item be set to :IMMEDIATE. If set to :EXTERNAL, youd trigger the instrument with a high TTL
19、level signal on the trigger terminals on the rear panel. If set to :BUS, youd trigger the instrument with a software trigger. Toggled transient operation In toggled transient operation, the load starts at the stored parameter for the mode. When a trigger is received, the load switches to the B value
20、. When another trigger is received, the load switches to the A value. It stays at the A value until another trigger is received, at which point it switches to the B value. Further triggers cause the load to switch between the A and B values. Heres an example: 10A 5A TRG TRG Toggled Transient Operati
21、on Here are the keystrokes needed to setup this example: KeysDisplay I-setStandard display of voltage and current. Enter a value of 5 A (you may need to press the I-set key again). Press Enter. EnterEnters the CC modes value. The standard display is shown. Shift + S-TranLEVEL A= X.XXXA You are being
22、 prompted for the first current value. Press the 5 key for 5 A. EnterEnters the 5 A value, then displays WIDTH A = X.XMS. Youre being prompted for the duration of the 5 A load. In the toggled mode of operation, this width is ignored, so enter any convenient value. 8500 DC Load Series Version: Februa
23、ry 4, 2009 Page 35 of 76 KeysDisplay EnterDisplays LEVEL B= X.XXXA. You are being prompted for the second current value. Press the 1 and 0 keys to enter 10 A. EnterEnters the 10 A value, then displays WIDTH B = X.XMS. Youre being prompted for the duration of the 10 A load. . In the toggled mode of o
24、peration, this width is ignored, so enter any convenient value EnterDisplays :CONTINUOUS, :PULSE, or :TOGGLED. Use the or arrow keys to display :TOGGLED. EnterReturns to the standard display of voltage and current. To activate this toggled transient condition, press Shift + Tran, then press On/Off.