BK 1471 Instruction Manual 电路图.pdf
《BK 1471 Instruction Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《BK 1471 Instruction Manual 电路图.pdf(46页珍藏版)》请在收音机爱好者资料库上搜索。
1、!47 1 D u al -T r ace Osc I I I osco p A Product of DYNASCAN CORP0RATI0N 1801 West Belle Plaine . Chicago, lllinois 60613 10 MHz, TRIGGERED SWEEP v v PRTCE $2.00 RadioFans.CN 收音机爱 好者资料库 lv b INSTRUCTION MANUAL FOR B brightness increases in logic low state, decreases in logic high state. v , SPECIFIC
2、ATIONS v VERTICAL AMPLIFIERS (CH A aNd CH B)TV SyncVertical and horizontal sync separator circuit provided so that any portion of complex TV wave- form can be synchronized and expanded for viewing. TVH (line) and TW (frame) sync switched automatically by SWEEP TIME/ CM switch. TW = 0.5 SEC/cm to 0.1
3、 mSEC/cm. TVH = 50 pSEC/cm to I pSEC/cm. HORIZONTAL AMPLIFIER (Horizontal Input through CH B Input) Deflection Factor .01 V/cm to 20 V/cm. Frequency Response DC to 800 kHz e3 dB). Input Resistance I megohm (nominal). Input Capacity 22 pF (t 3 pF). Madmum Input 300 V (ttC + AC peak) or 600 V Voltage
4、p-p. X-Y Operation With SWEEP TIME/CM switch in CH B position, the CH A input becomes the Y input (vertical) and the CH B input becomes the X input (horizontal). The CH B posi- tion control becomes the horizon- tal position control. CALIBRATION VOLTAGE I V p-p square wave (+ 5%) atline frequency. IN
5、TENSITY MODULATION VoltageTTL logic-compatible. Low logic - increases brightness; high logic decreases brightness. lnput Resistance 470 kCl (nominal). POWER REQUIREMENTS Input ll7 or 230 VAC, I lVo,5016O Ifz, 20 watts. (3-wire line cord, CSA-approved for oscilloscopes.) See Fig. 51. PROBES (Not Incl
6、uded) b Deflection Factor Calibration Accuracy Frequency Response Risetime Overshoot Ringing Input Resistance Input Capacity Max. Input Voltage Operating Modes Chop Frequency Channel Separation Sweep System Sweep Time Sweep Time Accuracy Sweep Magnification Horizontal Linearity TRIGGERING Source Slo
7、pe Triggering Range 0.01 V/cm to 2O Y lcm in I 1 calibrate d range s in l-2-5 sequence. ! 5% on all ranges. DC: DC to 10 MHz (- 3 dB) AC: 10 Hzto l0 MHz e3 dB). 35 nanoseconds. 3% or less at 100 kHz squarewave display. 3% or less at 100 kHz squarewave display. I megohm, + 5%. 22 pF (t 3 pF). 300 V (
8、DC + AC peak) or 600 V p-p. Channel A only. Channel B only. Dual-trace automatically chopped at all sweep times of I mS/cm and slower; alternate trace automati- cally selected for all faster sweep times. 2OO kHz (x 2Wo). Better than 60 dB I kHz. Triggered and automatic. In auto- matic mode, sweep is
9、 obtained without input signal. I pSEC/cm to 0.5 SEC/cm in 18 calibrated ranges, in l-2-5 se- quence. ! 5%. Obtained by enlarging the above sweep 5 times from center. Maxi mum sweep speed becomes O.2 pSEC/cm. 3Vo or less distortion. I N T a n d E X T ( l V p - p sensitivity). MODE switch selects sou
10、rce of internal trigger; the CH A signal is the triggering source in the CH A and DUAL modes, and the CH B signal is the triggering source in the CH B mode. Positive and negative, continuous- ly variable level control; pull for AUTO. 20 Hz to l0 MHz (rrrih. I cm deflection as measured on cathode ray
11、 tube). Model No. Attenuation lnput Impedances Connector Tip PR-208 or PR-24B. Combination l0: I and direct. l0:1 = l0 megohms, l8 pF. Direct = I megohm, 120 pF. BNC SpringJoaded, hook-on tip. SWEEP CIRCUITS (Common to CH A and CH B) v 6 7 8 10 15171819 Fig. 1. Front panel controls and indicators. O
12、PERATORS CONTROLS. INDICATORS AND FACILITIES v l . Cathode Ray Tube (CRT). This is the screen on which the waveforms are viewed. Scale. The 8 x l0 cm graticule provides calibration marks for voltage (vertical) and time (horizontal) measurements. Pilot Lamp. Lights when oscilloscope is turned on. SWE
13、EP TIME/CM Switch. Horizontal sweep time selector. Selects calibrated sweep times of 1 pSECicm (microsecond per centimeter) to 0.5 SEC/cm in l8 steps. In the CH B position, this switch disables the internal sweep generator and permits the CH B input to provide horizontal sweep. CAL I V P-P Jack. Pro
14、vides calibrated I volt peak-to- peak square wave input signal at the line frequency. This is used for calibration of the vertical amplifier attenuators. POSITION Control. Rotation adjusts horizontal position of traces (both traces when operated in the dual trace mode). Push-pull switch selects 5X m
15、agnifi- cation when pulled out (PULL 5X MAG): normal when pushed in. TRIGGERING LEVEL Control. Sync level adjustment determines points on waveform slope where sweep starts; (-) equals most negative point of triggering and (+) equals most positive point of triggering. Push-pull switch selects automat
16、ic triggering when pulled out (PULL AUTO). When automatic triggering, a sweep is generated even without an input signal. EXT TRIG Jack. Input terminals for external trigger signal. SYNC Switch. Four-position lever switch with the following positions. SLOPE. The SLOPE positions are used for viewing a
17、ll waveforms except television composite video signals. (+) Sweep is triggered on positive-going waveform. (-) Sweep is triggered on negative-going waveform. slope of slope of TV. In the TV positions, the sync pulses of a television composite video signal are used to trigger the sweep; the vertical
18、sync pulses (frame) are automatically selected for sweep times of 0.5 SEC/cm to 0.1 mSEC/cm, and horizontal sync pulses (line) are automatically selected for sweep times of 50 pSEC/cm to I pSEC/cm. (+) Sweep is triggered on positive-going sync pulse. (-) Sweep is triggered on negative-going sync pul
19、se. SOURCE Switch. Selects triggering source for the sweep. INT Sweep is triggered by CH A signal when MODE switch is in CH A or DUAL position. Sweep is triggered by Channel B signal when MODE switch is in CH B position EXT Sweep is triggered by an external signal applied at the EXT TRIG jack 8. I l
20、. Channel B POSITION Control. Vertical position adjust- ment for Channel B trace. Becomes horizontal position adjustment when SWEEP TIME/CM switch 4 is in the CH B position. 12. Channel B DC BAL Adjustment. Vertical DC Balance adjustment for Channel B trace. 13. Channel B INPUT Jack. Vertical input
21、jack of Channel B. Jack becomes external horizontal input when SWEEP TIME/CM switch 4 is in the CH B position. 14. Channel B DC-GND-AC Switch. DC Direct input of AC and DC component of input signal. GND Opens signal path and grounds input to vertical amplifier. This provides a zero-signal base line,
22、 the position of which can be used as a reference when performing DC measurements. AC Blocks DC component of input signal. 15. Channel B. VOLTS/CM Switch. Vertical attenuator for Channel B. Vertical sensitivity is calibrated in 1l steps from .01 to 20 volts per cm. This control adjusts horizontal se
23、nsitivity when the SWEEP TIME/CM switch 4 is in the CH B position. 16. MODE Switch. Three-position lever switch; selects the basic operating modes of the oscilloscope. CH A Only the input signal to Channel A is dis- played as a single trace. CH B Only the input signal to Channel B is dis- played as
24、a single trace. DUAL Dual-trace operation; both the Channel A and Channel B input signals are displayed on two separate traces. 17. Channel A VOLTS/CM Switch. Vertical attenuator for Channel A. Vertical sensitivity is calibrated in 1l steps, from .01 to 20 volts per cm. 18. Channel A DC-GND-AC Switc
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BK 1471 Instruction Manual 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf