1、M Megger Limited Archliffe Road, Dover Kent CT17 9EN England T +44 (0) 1304 502 101 F +44 (0) 1304 207 342 Megger PO BOX 9007, Valley Forge PA 19484-9007 USA T +1 (610) 676 8500 F +1 (610) 676 8610 Megger 4271 Bronze Way, Dallas, Texas 75237-1017 USA T +1 (800) 723 2861 T +1 (214) 330 3203 F +1 (214
2、) 337 3038 Megger SARL 29 Alle de Villemomble 93340 Le Raincy, France T +33 (1) 43.02.37.54 F +33 (1) 43.02.16.24 OTHER TECHNICAL SALES OFFICES Toronto CANADA, Mumbai India and BAHRAIN. Megger products are distributed in 146 countries worldwide. This instrument is manufactured in the United Kingdom.
3、 The company reserves the right to change the specifi cation or design without prior notice. Megger is a re g i s t e red trademark Part No. 6172-697 V02 Printed in England 11HH RadioFans.CN 收音机爱 好者资料库 USER GUIDE GUIDE DUTILISATEUR BENUTZERANLEITUNG GUA DEL USUARIO M BMM500 Series Insulation & conti
4、nuity testers t prior notice. RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 Contents Safety Warnings2 Description3 Operation4 Live Circuit warning4 Voltage testing4 Auto-shut off4 Backlight4 Insulation tests5 Locking Test Button (ltb)5 Polarisation Index Te s t i n g5 Automatic Discharge6 Zeroing
5、of Test Lead Resistance7 Possible sources of error7 Continuity Bleeper8 Resistance Tests (k)8 Diode T e s t i n g8 Voltage Tests (V)9 Battery Replacement10 Fuse Checking and Replacement10 Using the MEGGER SP1 Switched Probe11 Specifi cation12 Repair and Warranty19 1 Symbols used on the instruments a
6、re : Caution, risk of electric shock. Caution, refer to User Guide. Equipment protected throughout by Double Insulation (Class II). Equipment complies with current EU Directives. Equipment must not be connected to voltage sources 600V CAT II. Suitable for electrical installations CAT III 300V to Ear
7、th 600V 2 SAFETY WARNINGS Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. The circuit under test must be de-energised and isolated before connections are made except for voltage measurement. Circuit connections m u s t not
8、be touched during a test. After insulation tests, capacitive circuits must be allowed to discharge before disconnecting the test leads. The Live Circuit Warning and Automatic Discharge are additional safety features and should not b e regarded as a substitute for normal safe working practice. Replac
9、ement fuses m u s t be of the correct type and rating. Failure to fi t the correctly rated fuse will result in damage to the instrument in the event of an overload. Test leads, including crocodile clips, must be in good order, clean and have no broken or cracked i n s u l a t i o n . Ensure that han
10、ds remain behind guards of probes/clips when testing. U.K. Safety Authorities recommend the use of fused test leads when measuring voltage on high energy s y s t e m s . NOTE THE INSTRUMENTS MUSTONLY BE USED BYSUITABLY TRAINED AND COMPETENTPERSONS Users of this equipment and/or their employers are r
11、eminded that Health and Safety Legislation require them to carry out valid risk assessments of all electrical work so as to identify potential sources of electrical danger and risk of electrical injury such as from inadvertent short circuits. Where the assessments show that the risk is signifi cant
12、then the use of fused test leads constructed in accordance with the HSE guidance note GS38 Electrical Test Equipment for use by Electricians should be used. Description Congratulations on your purchase of a genuine Megger insulation/continuity tester. Megger has over 100 years experience in insulati
13、on testing which is refl ected in its product designs. Your BMM500 has been carefully developed to address the real needs and benefi ts of the user. The Megger BMM500 Series instruments are battery powered Insulation and Continuity testers, with a measurement capability from 0,01 Continuity to 10G I
14、nsulation. O ffering multi-voltage facilities, the instruments take full advantage of microprocessor t e c h n o l o g y and feature a large liquid crystal display combining digital and analogue readings. T h e analogue display has the benefi t of indicating trends and fl uctuations in readings, whi
15、le the digital readout gives direct accurate results. T h e display is also backlit giving clear visibility even in low light conditions. The BMM500 Series instruments have the unique capability of being able to measure voltages down to a resolution of 0,1mV. This gives the user the option to fi t a
16、 wide variety of transducers to further enhance the capabilities of the BMM Series instruments, eg temperature or humidity measurement. A customised connector on the top of the instrument enables the optional Megger SP1 Switched Probe to be used for two handed probe operation. The 250V, 500V and 100
17、0V ranges can be used to test electrical installations in compliance with BS7671 (16th Edition IEE Wi r i n g Regulations) IEC364 and HD384, since each range has a 1mA minimum test current at the minimum pass values of insulation specifi ed in these documents. Designed to IEC1010-1 the BMM500 Series
18、 are protected against connection to a 300V Category III supply. T h e instruments have a basic accuracy of 2% at 20C. The instruments are waterproof and dustproof to IP54. This helps maintain accuracy and ensures maximum reliability in harsh e n v i r o n m e n t s . 3 Operation Refer to Safety Wa
19、rnings before using the instrument Testing is automatically inhibited if: An external voltage 55V is present when switched to any insulation range position An external voltage 10V is present on all other ranges (excluding OFF/V). The external voltage is indicated on the display, on insulation ranges
20、 an audible bleeper will sound if a test is attempted. Live Circuit Wa rn i n g When more than 25V is applied to the terminals in the insulation ranges, the instrument defaults to a voltmeter and gives an audible warning. On all other switch positions except OFF/V when approx 10V is applied the defa
21、ult voltmeter will be activated. Testing will be inhibited. Voltage Testing on High Energy Systems Use extreme care when using or measuring voltages above 30V, particularly in high energy systems. Fused test leads are available as optional accessories for local situations where increased protection
22、is required. Auto-shut Off To conserve battery life, Auto-shut Off (preceded by a series of bleeps) operates after approx. 10 minutes of instrument inactivity on insulation, 5 minutes on all other ranges. If the instrument is switched on whilst holding the key, the Auto shut-off time is extended to
23、60 minutes. To restore operation after Auto- shut Off, select OFF followed by the required switch position. Note: It is recommended that the instrument is switched to the OFF position when not in use. B a c k l i g h t The backlight is activated by pressing the key. The backlight will remain illumin
24、ated for approx. one minute before automatically switching off to conserve battery life, 4 Operation alternatively thekey can be re-pressed. Insulation Tests (M) (See fi g. 1) The insulation tests apply a known voltage to the circuit under test and measure the resulting leakage current. The circuit