Biddle DETEX_UG 电路图.pdf
《Biddle DETEX_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle DETEX_UG 电路图.pdf(44页珍藏版)》请在收音机爱好者资料库上搜索。
1、 The Measure of Excellence in Electrical Testing The industry leader since 1895, Megger offers a comprehensive line of electrical test and measurement products, from portable instruments for use in the field to fully-integrated systems for high voltage systems testing. Megger fulfills a range of req
2、uirements found in electric utility, large industrial, electrical apparatus manufacturing, military and governmental applications worldwide. PORTABLE FIELD TEST EQUIPMENT Meggers extensive product line includes its well known portable field test equipment, including the Megger family of Insulation R
3、esistance testers, which indicate the deterioration of electrical insulation; Ground Resistance Testers for installing and maintaining grounding systems; and equipment for locating faults in both power and communications cable. PRECISION TEST they are not proximity devices. Therefore, their fork or
4、hook terminals must actually touch the bare conductor being tested for at least 3 seconds to work properly. Voltage detectors are designed to operate only on systems referenced to ground. Erroneous indications will occur when testing ungrounded delta or wye systems. Correct indications by the instru
5、ments depend on their being used with the correct system. Cat. No. 514360-2, 514360-3, 514360-4, 514242-1, 514242-2, 514500-3, 514500-4 instruments (those supplied without integral poles) are showerproof. They are not waterproof and could be rendered inoperative if immersed. When using these detecto
6、rs and testers in rain or snow, care must be taken to follow all safety precautions as suggested by the manufacturer of the hot line pole being used. In particular, make sure that the hot line pole used has a wet rating at least equal to the voltage of the system under test. Also make sure that it i
7、s clean and free from imperfections, such as cracks and chips. 5 Cat. No. 514440-2, 514360-1, 514500-1, 514500-2, and 510836-1 instruments (those supplied with integral poles) should not be used in rain or snow. They do not have a wet rating. When checking for the absence of voltage, detectors and t
8、esters should be tested both before and after use to make sure they are operating properly. It is best to make this test on a live portion of the same circuit being tested. This will ensure that the sensitivity of the detector is satisfactory for the particular application. As an alternative, make t
9、he tests on another circuit of similar rating and in similar lighting conditions. Before touching or working near de-energized circuits or apparatus, make sure that they are grounded using appropriate safe grounding techniques. Conductors and cables used for grounding must be capable of handling the
10、 maximum possible current. Make sure that the nominal voltage of the apparatus under test is within the voltage range specified on the instrument. NOTE The voltage specified on voltage detectors refers to nominal system line voltage. The actual operating voltage range of the detector is the voltage
11、specified, divided by 1.73. 6 7 Section 3 Equipment Tabulation and Specifications VOLTAGE DETECTORS (For ac use only, grounded circuits only) Cat. No Type Operating Range (kV) ph-ph Style Weight lb (kg) 514242-1 Electronic 69 to 230 Spline Fitting 1.5 (0.67) 514242-2 Electronic 230 to 500 Spline Fit
12、ting 1.5 (0.67) 514360-1 Electronic 2.4 to 6.9 Telescopic Pole 34 to 51 in. (86 to 129 cm) 2.2 (0.99) 514360-2 Electronic 4.16 to 13.8 Spline Fitting 1.1 (0.50) 514360-3 Electronic 12 to 34.5 Spline Fitting 1.1 (0.50) 514360-4 Electronic 24.9 to 69 Spline Fitting 1.1 (0.50) 514440-2 LED 4.16 to 34.5
13、 Telescopic Pole 34 to 49.5 in. (86 to 126 cm) 2.1 (0.95) Detectors are supplied with vinyl carrying cases. PHASING TESTERS (For ac use only, grounded or ungrounded circuits) Cat. No Type Operating Range (kV) Style Weight lb (kg) 514500-1 Meter 1 to 7 Two Pole 4.0 (1.8) 514500-2 Meter 4 to 36 Two Po
14、le 4.7 (2.1) 514500-3 Meter 13 to 80 Spline Fitting 4.3 (1.9) 514500-4 Meter 4 to 36 Spline Fitting 4.3 (1.9) 510836-1 LED 2.1 to 36 Two Pole 3.0 (1.4) Testers are supplied with metal carrying cases. 8 ACCESSORIES Cat. No. 512117 Pneumatic Rubber Glove Tester Size: 5-1/2 in. (14 cm) high; 5 in. (12.
15、7 cm) diameter Weight: 1-1/2 lb (0.7 kg) Cat. No. 510005 Piezo Verifier Size: 7 in. (18 cm) Weight: 3/4 lb (0.34 kg) 9 Section 4 Description and Operation of the Detex Voltage Detectors PRECAUTION Be sure to read and understand Section 2, Safety, of this manual before operating the voltage detector.
16、 Even after determining that a circuit is de-energized by use of the detector, it may still carry an induced voltage, a capacitively coupled voltage, or an applied voltage lower than the operating range of the detector. The circuit under test must be grounded before being touched. ELECTRONIC VOLTAGE
17、 DETECTORS These single-pole voltage detectors are used to verify the absence of voltage in the detectors range on a line or terminal of any grounded ac electrical system. The presence of ac voltage is detected with respect to ground by making contact between the detector and the live equipment. The
18、 three-step procedure of testing the detector, testing for absence of high voltage, and testing the detector again should be strictly observed. Cat. No. 514360 and 514242 series detectors, see Figure 1, use an electronic detection circuit powered by batteries enclosed in the assembly. The presence o
19、f voltage is indicated by an audible signal sounding and by a red light-emitting diode (LED) flashing. Absence of these signals indicates that the conductor or termination under test is free of voltage above the low voltage limit of the detector. To activate the detector test system, briefly press t
20、he red TEST button. The audible signal sounds and the red LED flashes for a short time. The green LED lights for approximately two minutes indicating that the detector is operational and ready for use. The green LED extinguishes when the presence of voltage is detected as indicated by the audible si
21、gnal sounding and by the red LED flashing. Note that the Cat. No. 514242 series detectors have four red LEDs for ease of visibility. Except for the Cat. No. 514360-1 detector, which is equipped with a telescopic pole, detectors with spline fittings must be attached to a universal 10 connection on th
22、e end of the proper length hot line pole rated for the voltage of the system being tested. Figure 1: Detex Electronic Voltage Detectors GREEN LED RED LEDs TEST BUTTON SOUND INDICATOR SOUND INDICATOR ROD ATTACHMENT FITTING RED LED GREEN LED TEST BUTTON 11 LED VOLTAGE DETECTOR The Cat. No. 514440-2 LE
23、D voltage detector shown in Figure 2 uses a lamp as the detecting device, with the lamp connected on one side to the contact terminal and on the other side to an external conducting electrode. A small gap is incorporated in series with the lamp. The extremely sensitive lamp is illuminated by a very
24、small current resulting from the capacitive effect between the internal electrode and ground. This detector operates only on grounded ac systems. The detector has a strong molded thermoplastic housing and a built-in TEST button. On recent models (identified by a green label sticker), the TEST button
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle DETEX_UG 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


