1、 PN 2572573 July 2006, Rev. 1, 2/07 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies. 114, 115, and 117 True-rms Multimeters Users Manual RadioFans.CN 收音机爱 好者资料库 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke
2、product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable bat- teries, or damage from accident, neglect, misuse, alteration, contamination, or abnor- mal conditions of operation or handling. Resellers are n
3、ot authorized to extend any other warranty on Flukes behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS
4、 YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUEN- TIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or l
5、imitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99 RadioFans.CN 收音机爱 好者资料库 1 True-rms Mult
6、imeters Introduction The Fluke Model 114, Model 115, and Model 117 are battery-powered, true-rms multimeters (hereafter the Meter) with a 6000-count display and a bar graph. This manual applies to all three models. All figures show the Model 117. These meters meet CAT III IEC 61010-1 2 nd Edition st
7、andards. The IEC 61010-1 2 nd Edition safety standard defines four measurement categories (CAT I to IV) based on the magnitude of danger from transient impulses. CAT III meters are designed to protect against transients in fixed-equipment installations at the distribution level. Contacting Fluke To
8、contact Fluke, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore +65-738-5655 Anywhere in the world: +1-425-446-5500 Visit Flukes web site at . Register your Meter at . Unsafe Voltage To alert you to the presen
9、ce of a potentially hazardous voltage, the Y symbol is displayed when the Meter measures a voltage 30 V or a voltage overload (OL) condition. When making frequency measurements 1 kHz, the Y symbol is unspecified. Test Lead Alert XWXWWarning Personal injury or damage to the Meter can occur if you att
10、empt to make a measurement with a lead in an incorrect terminal. To remind you to check that the test leads are in the correct terminals, LEAd is briefly displayed and an audible beep sounds when you move the rotary switch to or from any A (Amps) position. RadioFans.CN 收音机爱 好者资料库 114, 115, and 117 U
11、sers Manual 2 Safety Information A XWWarning statement identifies hazardous conditions and actions that could cause bodily harm or death. A WCaution statement identifies conditions and actions that could damage the Meter or the equipment under test. To avoid possible electric shock or personal injur
12、y, follow these guidelines: Use the Meter only as specified in this manual or the protection provided by the Meter might be impaired. Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. Always use proper terminals, switch position, and range for meas
13、urements. Verify the Meters operation by measuring a known voltage. If in doubt, have the Meter serviced. Do not apply more than the rated voltage, as marked on Meter, between terminals or between any terminal and earth ground. Use caution with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. T
14、hese voltages pose a shock hazard. Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance. Do not use the Meter around explosive gas or vapor. When using test leads or probes, keep your fingers behind the finger guards. Only u
15、se test leads that have the same voltage, category, and amperage ratings as the meter and that have been approved by a safety agency. Remove test leads from Meter before opening the battery door or Meter case. True-rms Multimeters Safety Information 3 Comply with local and national safety requiremen