1、Insulation & Continuity Testers MEGGERBM400/2 Series User Guide www.MeterC (800) 230-6008 SAFETY WARNINGS ,Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. ,The circuit under test must be de-energized and isolated before con
2、nections are made except for voltage measurement (BM400/2, BM401/2 and BM403/2 only). ,Circuit connections must not be touched during a test. ,After insulation tests, capacitive circuits must be allowed to discharge before disconnecting the test leads. ,The default voltmeter and automatic discharge
3、are additional safety features and should not be regarded as a substitute for normal safe working practice. ,Test leads and crocodile clips, must be in good order, clean, with no broken or cracked insulation. ,Replacement fuses must be of the correct type and rating. See Specification. ,U.K. Safety
4、Authorities recommend the use of fused test leads when measuring voltage on high energy systems. NOTE THEINSTRUMENTSMUSTONLYBEUSEDBYSUITABLYTRAINEDAND COMPETENT PERSONS Before using the instrument, follow the separate instructions provided to fit either the locking or non-locking test button. AVO IN
5、TERNATIONAL recommend the fitting of the non-locking test button. Hands free operation is provided on all ranges except the insulation ranges. If the locking button is fitted, extra care must be taken. Symbols used on the instruments are: Caution, risk of electric shock Caution, refer to accompanyin
6、g documents Equipment protected throughout by Double Insulation (Class II) Equipment complies with current EU Directives. RadioFans.CN 收音机爱 好者资料库 GENERAL DESCRIPTION The B M 4 0 0 / 2 Series instruments are battery powered Insulation and Continuity testers, with a measurement capability from 0,01 Co
7、ntinuity to 999 M Insulation. Offering multi-voltage facilities, the instruments take full advantage of microprocessor technology and feature a large liquid crystal display combining digital and analogue readings. The analogue display has the benefit of indicating trends and fluctuations in readings
8、, while the digital readout gives direct accurate results. A customized connector on the top of the instrument enables the optional Megger SP1 Switched probe to be used for two handed probe operation. Available as an optional extra, the Megger DLB Downloading Base can be fitted for realtime download
9、ing of measured test results to a Personal computer via an RS232 serial lead. The optional miniature clip-on current transducer MCC10 enables the instrument to measure a.c. currents from 1 A to 10 A, with a resolution of 0,1 A. Designed to IEC1010-1 the B M 4 0 0 / 2 Series are protected against con
10、nection to a 440 V Category III supply. The instruments have a basic accuracy of 2% at 20 C. The instruments are waterproof and dustproof to IP54. This helps maintain accuracy and ensures maximum reliability in harsh environments. OPERATION Testing is automatically inhibited if: An external voltage
11、55 V is present when switched to any Insulation position. An external voltage 25 V is present on all other ranges (excluding Voltmeter position). The external voltage is indicated on the display (flashing V on the BM402/2 & BM404/2) and the bleeper sounds intermittently. Auto-shut Off To conserve ba
12、ttery life, Auto-shut Off (preceded by a series of bleeps) operates after 12 minutes of instrument inactivity in all insulation test switch positions, and after 5 minutes of instrument inactivity in all other switch positions. If desired, the 5 minute shut-off can be changed to 60 minutes (non insul
13、ation test switch positions). To do this, first perform a battery check, then press the TEST button twice to show (60). If an insulation test, or O F F is subsequently selected, the shut-off time reverts to the default times. It is therefore not possible to generate dangerous voltages for more than
14、12 minutes, even with a locking test button. To restore operation after Auto-shut Off, select O F F followed by the required switch position. N o t e : Auto-shut Off has a small power consumption and it is recommended that the instrument is switched to off when not in use. This is particularly impor
15、tant at the end of the working day, since no battery power is used in the OFF position. Refer to Safety Warnings before using the instrument RadioFans.CN 收音机爱 好者资料库 INSULATION TESTS (M) Insulation tests operate only when the T E S T button is pressed. Grey labelling denotes where it is necessary to
16、press the test button.To prevent damage to the instrument from accidental connection to a live circuit, the test button must not be pressed (or locked down) before connecting to the item under test. 1. Set the selector switch to the test voltage required. 2. Connect the test leads, first to the inst
17、rument, and then to the isolated item under test. 3. Press the TEST button to activate the test voltage.Take the reading. 4. Release the TEST button at the end of the test. The reading will hold for a few seconds. 5. Capacitive circuits charged during a test will automatically discharge. The Live Ci
18、rcuit Warning is displayed If significant voltage remains. 6. Remove the test leads only when no voltage is indicated. Note: There is a safety delay of 3 seconds on the first operation on the 1000 V range, each time the range is selected. Automatic Discharge When the test button is released after an
19、 insulation test, a 250 k resistor is automatically switched across the terminals to discharge the item under test. Any voltage present will be indicated on the display so that the discharge can be monitored (except on the B M 4 0 2 / 2 and B M 4 0 4 / 2, which will display a flashing V.) Polarizati
20、on Index Testing (PI) All insulation ranges can be used for PI testing. PI is the resistance value after 10 minutes divided by the resistance value after 1 minute. More detailed information on PI Testing and value assessment can be found in AVO International publications listed in the Accessories. C