BK 1602 Instruction Manual 电路图.pdf
《BK 1602 Instruction Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《BK 1602 Instruction Manual 电路图.pdf(16页珍藏版)》请在收音机爱好者资料库上搜索。
1、I SOLID STATE, HIGH.VOLTAGE, REGULATED DC POWER SUPPLY i trIYNASCAN COF|POF|ATION RadioFans.CN 收音机爱 好者资料库 C O N T E N T S PAGE SPECIFICATIONS 3 FEATI.JRES 3 INTRODUCTION 4 OPERATING CONTROLS 4 OPERATING INSTRUCTIONS 5 APPLICATIONS .7 CIRCI.JIT DESCRIPTION . . .I1 MAINTENANCE .13 CALIBRATION .l3 FUSE
2、 REPLACEMENT . . .14 WARRANTY Cov- 3 RadioFans.CN 收音机爱 好者资料库 INPUT VOLTAGE 4OOV DC SUPPLY Output Voltage: Output Current: Grrrent Limit Adjust- ment/Protection: Load Regulation: Line Regulation: Noise NET WEIGHT: SPECIFICATIONS 105 - I25VAC, 60 Hz 0 - 400V, continuously vari- able. 0 - 20OmA. lOmA t
3、o 200rnA, continu- ously variable-sets trip cur- rent to shut-down supply out- put. 0.1% at high end. 0.t%. Less than lOmV peak-to-peak. 0 - 100V, continuously vari- able. 0 - 2mA. r% lVo Less than 1OmV peak-to-peak. Current-limiting resistance. 6.3V !57o, full load; I IOVAC primary. 3.5A continuous
4、. Thermal circuit-breaker. 6.3V !5%,fuII load; I I0VAC primary, each side to center-tap. 3.5A continuous. Thermal circuit-breaker. 0 to 400V DC (400V supply only), !37o. 0 to l00V DC (100V supply only), !3%. Range selected by switch. 0 to 200mA (monitors 400V supply only), t3%. 14-118 x 3-7 f 8 x 10
5、 deep. I I lbs. FEATURES Fully solid state, utilizing integrated circuits, silicon transis- tors and diodes and one SCR. Among the advantages of solid state construction are dependability, no warm-uf time or stabilization delay, ruggedness, compact size. Current Umiting/Overload Protection: Protects
6、 load and instrument against overload. Pre-settable automatic current shutdown, fully adjlstable from l0rnA to 200mA provided on.the B+ output. Resistive limiting protects the C- supply and load. The 6.3VAC and the 12.6IAC heater windingdinb loads are protected by a resettable circuit breaker. Simpl
7、ified Cunent Shutdown Setting: Permits setting B+ current shutdown point without disturbing external load connections or output voltage settings; does not require application of short circuit to output terminals. sirirply press the button and adjust the CURRENT SET controi tb the desired setting on
8、the current meter. O400V, G200mA: Output voltage continuously adjustable over.entire -rgnge wjth g single control; no range switching required. Fully regulated output at all levels. G100V, G2mA: Output voltage continuously adjustable gver. entire rang with a single control; indepehdently tloating ou
9、tput. Can be used independently of the 0400V oglpgt or can be used with either polarity referenced to the 400V output. 6.3VAC, I2.6VAC CT, G3.5A: Independently floating AC sources. Dual Meters: Allow B+ supply output voltage and B+ supply current drain to be monitored simultanebusly. The voltmeter c
10、an also be switched to monitor the bias iupply voltage. Both meters have overload protection to prevent damage from excessive loading. one current Range: Simplifies current shutdown setting by requiring only one adjuitment. Two Voltmeter Ranges: 0-400V and Gl00V ranges for the B+ and C: supplies res
11、pectively provide maximu=m resolu- tion with a minimum effort to the user. Standby-DC On Switch: Disconncts the DC supplies from external loads without disturbing voltage or iurrent set- tings. Pilot- Lamp: Lights up to indicate at a glance that the supply is on. Mechanical he-Regulator: B+ supply r
12、ectifier voltage is increased in progressive steps as output is increasea. inis improves efficiency as less power is converted to heat at low voltage output. Floating outputs: Permit referencing the positive or nega- tive outp_uls of the -B+ supply and the C- supply to any external DC potential or g
13、rounds. Reverse ?olarity hotection: Prevents against accidental damage from reverse polarity connections to an external power source. Attractive, Functional tlesign: Permits stacking of units when more than one power supply is required. - Ery t9. Ope_rate: All controls are identified and easy to rga
14、d- Simplified operation helps prevent operator mistakes that might damage equipment. - RadioFans.CN 收音机爱 好者资料库 The B and AC voltages and currents of 6.3 and I2.6VAC at 0-3.5A. The high perfor- mance, operating ease, and special features make it an excellent choice- for most applications requiring a
15、high voltage DC power source. It is wellsuited for,powering fully -solid siate circuits, tube type circuits,. and hybrids. Unlike some supplies, the user can rectify the AC.source and have 3 indefendent supplies for powering digital/analog circuits, etc. Following is a list of some of the most popul
16、ar applications of 1602: o Service Technicians: Powering high voltage solid state equipment, or individual circuits consisting of transis- tors, vacuum tubes or both. o Factory Technicians: Powering complete equipment or individual assemblies during testing in the factory. o Engineers and l:boratory
17、 Technicians: Powering pro totypes and experimental equipment. o Electronics Instructors and Students: Laboratgry ex- periments in basic and advanced electronics. CONTROLS 14 12 11 Fig. 1. Controls and Indicators. INTRODUCTION OPERATING 86 l. 2. CURRENT METER. Measures actual B+ output load current
18、during normal.operation. Indicates Bt current limit when set/reset switch 3 is pustred. B+ CURRENT SET. Provides adjustment of B* cur- rent limit. Continuously adjustable from l0-200mA output current. B+ CURRENT PUSH TO SET AND RESET (SET/ RESET) BUTTON: When fully depressed and held, connects cunen
19、t meter 1 fo read the B+ current limit setting. When pressed and released, resets B+ overload circuit if it has been tripped. OVERLOAD INDICATOR (RED). Lights when B+ current limit has been exceeded and the B+ zupply has strut down. STBY ON. STBY position: Removes power from terminals 8, 9, 13, and
20、14, and voltmeter 10, but leaves the DC supplies activated and at standby condition. ON posifion: Applies power to oirtput terminals 8, 9, 13, 14, and voltmeter 10. 6. POWER. Ughts continuously when power supply is turned on. 7. TERMINAL. Earth and chassis ground terminal- B+ TERMINALS 8. + TERMINAL
21、. Positive polarity of B+ output. 9. - TERMINAL. Negative polarity of B+ output. 10. VOLTMETER. Indicates output voltage of B+ or C- srpplies. ll. METER RANGE. B+/G400 position: Selects full scale ranse of 400 volts for voltmeter 10 to meter $+ output vollage. C-/G100 position: Selects full scale ra
22、nge of 100f for voltmetei 10 to meter C- output voltage. 12. LEVEL (B+). Turns off power supply at extreme counterclockwise rotation. Clockwise rotation turns on power supply and adjusts B+ output voltage upwards. 3. 4. 5. og Be C-TERMINAI,s 13. - TERMINAL. Negative polarity odtput of C- supply. 14.
23、 + TERMINAL. Positive polarity output of C_ supply. 15. C- CONTROL. ,gsts C- output voltage between terminals 13 and t4 from 0 to-100V witf, clockwise rotation. Output voltage is monitored on Volt- meter 10 when METER RANGE Switch 1l is in C-lGl00V position. 16. ;_ quired. a. Use only a polarized 3-
24、wire outlet. This assures that the power supply chassis is connected to a good.earth. ground and prevents danger from electrical shock. lf a 2-wire to 3-wire- adapter m_ust be used, be sure the ground wire of the adapter is attached to a good earth ground. b. If a circuit under test requires applica