1、M MIT520 5kV Digital Insulation Tester USER MANUAL RadioFans.CN 收音机爱 好者资料库 GSAFETY WARNINGS Safety Warning must be observed during use. IThe circuit under test must be switched off, de-energised, isolated and checked to be safe before insulation test connections are made. Make sure the circuit is no
2、t re-energised whilst the instrument is connected. ICircuit connections must not be touched during an insulation test. IAfter completing a test, capacitive circuits must be completely discharged before disconnecting the test leads. Capacitive charges can be lethal. ITested items should be firmly sho
3、rted out with a shorting link, after discharge, until required for use. This is to guard against any stored dielectric absorption charge subsequently being released thereby raising the voltage to potentially dangerous levels. IThe voltage indicator and automatic discharge features should be regarded
4、 as additional safety features and not a substitute for normal safe working practice. IIt is rare, but in certain circumstances, breakdown of the circuit under test may cause the instrument to terminate the test in an uncontrolled manner, possibly causing a loss of display while the circuit remains
5、energised. In this event, the unit must be turned off and the circuit discharged manually. ITest leads, including crocodile clips, must be in good order, clean and with no broken or cracked insulation. IThe instrument should not be used if any part of it is damaged. IWater on the surface of the inst
6、rument may lead to erroneous results. It is recommended that the instrument is not used in wet weather conditions. IThis instrument is not intrinsically safe and must not be used in hazardous atmospheres. 2 NOTE THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. RadioFans.CN
7、 收音机爱 好者资料库 Pre-Test / during test key action table14 Test mode summary15 Insulation resistance IR test15 Breakdown mode / burn mode15 Alarm limit mode15 Step voltage SV test16 Polarisation index PI test, and dielectric absorption ratio DAR test16 Dielectric discharge DD test16 Specifications18 Acce
8、ssories19 Repair and warranty20 Symbols used on the instrument are: FCaution: risk of electric shock GCaution: refer to accompanying notes tEquipment protected throughout by Double Insulation (Class II) cEquipment complies with current EU directives. Terms used in this manual The word must is used t
9、o indicate that the instructions following should be followed under all circumstances. Failure to follow these instructions could result in damage to the instrument and / or a hazard to the operator. The word should is used to indicate that the instructions indicate best practice. CONTENTS 3 Safety
10、warnings2 Introduction4 General description4 Features4 Cleaning4 Power lead and battery charging5 Instrument controls and indicators6 Power On/Off button7 Test voltage L and M buttons7 Test start / stop button7 /I button7 Bbutton10 Fn button10 Mode button10 Timer L and M buttons11 Record button11 Re
11、cording to on-board memory11 Downloading results11 Deleting results11 Recording to a PC11 High voltage warning LED12 Line input present LED12 Test terminals12 Guard terminal12 RS232 / USB connections12 Battery bar graph13 Voltage at terminals13 Timer indicator13 Digital display13 Analogue display14
12、Secondary display14 RadioFans.CN 收音机爱 好者资料库 Features IContinuous resistance or current measurement on main display. IOptional resistance, current, or figure of merit measurements on secondary display. IStandard test voltages 250 V , 500 V , 1 kV , 2.5 kV , 5 kV INon-standard test voltages selectable
13、 between 50 V and 1 kV in 10 V steps, and selectable between 1 kV and 5 kV in 25 V steps. ITest modes include insulation resistance, polarisation index, step voltage and dielectric discharge. IThe dielectric absorption ratio is automatically calculated if the corresponding timers are set. IEither bu
14、rn or breakdown selectable in insulation resistance mode. IInsulation Alarm Limit available in insulation resistance mode. IProgrammable timers include a main test duration timer, plus T1 and T2 timers for time resistance method type tests. ILoad capacitance and time constant measurements displayed
15、at end of test. ILCD backlight. IData storage, data retrieval and real time data output. IUSB or RS232 communications. IBattery level / charge level indicator. Cleaning Disconnect the instrument and wipe it with a clean cloth slightly damped with soapy water or Isopropyl alcohol (IPA). INTRODUCTION
16、4 General Description The MIT520 is a microprocessor controlled 5 kV insulation tester offering measurement capability of up to 15 T. The instrument performs automatic tests and has data storage and data retrieval facilities. Polarization index and dielectric discharge tests are performed automatica
17、lly, and test duration and voltages can be adjusted according to user preference for these tests. A step voltage test can be performed automatically, with a default voltage of 1 kV , and test duration of 5 minutes. It is possible for the user to set different voltages and test durations for the step
18、 voltage test. The MIT520 can be powered from the mains supply or by its own internal rechargeable battery, which provides for at least 6 hours of continuous testing. A battery level indicator on the LCD display indicates battery capacity. Connecting power to the mains supply connector will automati
19、cally charge the battery whether the instrument is switched on or off. A high level of internal isolation allows the instrument to be used while the unit is supplied from the mains. An internal battery management system switches the instrument off after ten minutes of inactivity. If the battery appr
20、oaches a very low state of charge the instrument turns itself off, and mains power must be applied before the instrument can be used again. Recorded test results and settings will not be lost when the instrument is switched off. A comprehensive LCD display shows resistance, current, capacitance, tim
21、e constant, voltage, timer measurements, and figure of merit measurements such as polarisation index. POWER LEAD AND BATTERY CHARGING 5 If the power lead supplied is not suitable for your mains connection, do not use an adaptor. Always use a power lead fitted with the correct plug. The instrument is
22、 fitted with a two-pin IEC60320 power inlet. Most power leads are made with three-core cable, so the ground connection will not be used. Power lead connection table ConnectionUK/InternationalUSA Earth/Ground Yellow/Green Green Neutral Blue White Live (Line) Brown Black If using a fused plug, ensure
23、that it is fitted with a 3 Amp fuse. The instrument can be powered from 85 - 265 Vrms a.c. at 50/60 Hz. The battery will charge as long as the mains supply is connected, except when a test is in progress. The power On/Off button has a green LED, which illuminates when mains power is present. For opt
24、imum battery life, charge the battery after each use. A completely exhausted battery will take 14 hours to recharge. INSTRUMENT CONTROLS AND INDICATORS 6 Measurement terminals -veguard+ve RS232USBLine input Time L and M selectors Time L and M selectors Line input Present indicator Power on/off /I se
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle MIT520_UG 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf