Biddle OTS_UG 电路图.pdf
《Biddle OTS_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle OTS_UG 电路图.pdf(98页珍藏版)》请在收音机爱好者资料库上搜索。
1、Oil Test Sets OTS60AF/2, OTS80AF/2 and OTS100AF/2 User Guide Guide de lutilisation Gebrauchsanleitung Gua del usuario FOSTER MEGGER RadioFans.CN 收音机爱 好者资料库 SAFETY WARNINGS The Oil Test Set must be properly earthed. The test chamber must be kept scrupulously clean. If the test chamber cover is cracke
2、d or damaged in any way, the test set must not be used, but sent for repair to an authorised agent. A routine continuity check between the emc/discharge barrier and the earth point should be made weekly (see page 9, section 5). The correct type of oil test vessel must be used, and correctly position
3、ed on the support horns before carrying out any testing (see page 9, section 7). Replacement fuses must be of the correct type and rating. Safety warnings and precautions must be read and understood before the instrument is used. They must be observed during use. NOTE THE TEST SET MUST ONLY BE USED
4、BY SUITABLY TRAINED AND COMPETENT PERSONS. 2 Symbols used on the instrument Caution: Refer to accompanying notes. Risk of electric shock. Equipment complies with relevant EU Directives Earth terminal RadioFans.CN 收音机爱 好者资料库 Safety Warnings 2 General Description4 Applications6 Specification7 Accessor
5、ies 8 Operation Warnings 9 Preparing the test vessel10 Loading the test vessel11 Preparing the oil test set12 Automatic testing sequences14 5 minute test15 AS 1767, BS 148, BS 5874, CEI 10 -1, EN60156, IEC 156, IP 295, NFC 27, OCT 6581, SABS 555, STAS 286, UNE21 and VDE 0370 tests17 ASTM D877 test18
6、 ASTM D1816 test18 Custom test 19 Withstand (Proof) tests21 BS 5370a test23 Self check tests25 Calibration check26 Printer facilities27 Downloading Results to a PC28 Print out information29 Fuse replacement 29 Sampling and Testing Oil for Dielectric Strength30 Guide de lutilisation31 Gebrauchsanleit
7、ung53 Gua del usuario75 Repair and Warranty97 ILLUSTRATIONS Figure 1 OTS100AF/2 oil test set layout5 Figure 2 Oil test set controls etc5 Figure 3 Oil test set rear panel5 Figure 4 OTS80AF/2 and OTS100AF/2 oil test vessel10 Figure 5 OTS60AF/2 oil test vessel 10 Figure 6 Spring contact on test chamber
8、 cover11 Figure 7Initial stir mode selection display screen15 Figure 8Initial stand time display screen15 Figure 9 Applied voltage display screen15 Figure 10 Stirring mode display screen16 Figure 11 Intermediate stand time display screen16 Figure 12Average breakdown voltage display screen16 Figure 1
9、3 Oil test vessel for ASTM D1816 specification19 Figure 14Custom test display screen20 Figure 15Withstand test initial stand time selection display screen21 Figure 16Withstand test voltage display screen22 Figure 17Withstand test options display screen22 Figure 18 BS 5730a Equipment Category selecti
10、on display screen23 Figure 19BS 5730a electrode gap selection display screen23 Figure 20BS 5730a Start test screen display23 Figure 21BS 5730a PASS - FAIL display screens24 Figure 22BS 5730a Test results display screen24 Figure 23OTS/VCM100 Calibration unit26 Figure 24OTS/VCM100 display screen 26 Fi
11、gure 25 Typical 9 and 25 Way D type plug and socket connections to external printer27 Figure 26Typical test sequence print-out29 3 Contents RadioFans.CN 收音机爱 好者资料库 The OTS60AF/2, OTS80AF/2 and OTS100AF/2 are transportable, easy to operate, oil test sets. A voltage selector fitted on the mains supply
12、 input panel at the rear permits the test sets to be operated from either 110 V, 120 V, 220 V or 240 V 50 Hz/60 Hz mains power supplies. The casing is made of sheet steel and carrying handles are fitted at each side. The whole construction is very robust. Incorporated within the casing is the test c
13、hamber of moulded plastic construction with a hinged polycarbonate cover. Protruding into the chamber from its floor are two horns; through these pass the high voltage transformer output connections, to cradle terminals one at the top of each horn. The test vessel containing the sample of oil to be
14、tested, is placed on these cradle terminals. Within the test vessel are mounted two electrodes. The shape of the electrodes and the gap set between them is determined by the particular national oil testing specification to be used. The vessel itself is of cast resin construction made in two parts. T
15、he electrodes are automatically connected to the cradle terminals when the vessel is placed on the horns. Inset into the top rear panel of the test chamber is a supply socket. This provides an independent power supply for the optional ASTM D1816 American test vessel which has an impeller type oil st
16、irrer. Oil stirring may also be achieved by a magnetic stirrer bar driven by a rotating magnetic field generated from beneath the test chamber. This magnetic field is only generated when required, under software control. The hinged cover to the test chamber is fastened by a trapped key interlock swi
17、tch. This is a safety feature whereby high voltage cannot be applied to the test chamber unless the interlock is closed. Should the interlock be released during an oil testing sequence, the high voltage will be automatically cut off and the test aborted; the display will indicate that this has occur
18、red. However, the mains supply will still be applied and the On/Off switch will still illuminate. Note:- User settable parameters and test results are stored in non-volatile memory (referred to as NOVRAM) and are unaffected by the operation of the test chamber interlock or by power failures. The con
19、trol panel is to the right of the test chamber. Once the testing specification has been selected and a test initiated (via the control panel) the operator is free to do other work while the test sequence is automatically carried out. Below the control panel an integral printer is fitted so that a pe
20、rmanent record of any test results may be obtained. A 9 Way D type plug is fitted to the test set to enable an external printer to be connected if required. Control Panel Test circuitry is controlled by a microprocessor and all the inherent benefits of pre-programmed tests, menu selection of functio
21、n and memory storage of test results are available. Panel controls are: (i) An On/Off power supply rocker switch which illuminates in the On position. (ii) Three tactile keys for making menu selections and generally controlling the test sequences. (iii) A tactile key for advancing the paper through
22、the internal printer. The display is a liquid crystal dot-matrix type giving full information in alpha-numeric form. The display shows the tests which are available, allocates names to the tactile control keys according to the programme adopted, shows the voltage being applied during a test and revi
23、ews the individual test breakdown voltage results when a test sequence is concluded (plus showing the average breakdown voltage and standard deviation). An L.ED. on the control panel illuminates to indicate that a high voltage is being applied to the test electrodes. The menus, and their information
24、 shown on the display are straightforward and simple to follow. The text of the operating section of this instruction book gives detailed information which, after the set has been used once, will probably only need to be referred to if difficulties arise, but please ensure you read thesection entitl
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle OTS_UG 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf