1、 Model 187 all previously activated button features (HOLD, Hz, etc.) are discarded. The automatic power off is preset to 15 minutes. From the Setup menu (see Chapter 5), you can specify a maximum period of 23 hours, 59 minutes. If you set the period to 0, the meter remains on until you turn the rota
2、ry switch to OFF or the batteries become too weak. Automatic power off does not occur if the meter is in MIN MAX, FAST MN MX, AutoHOLD, or LOGGING (Model 189) mode. Getting Acquainted Battery Considerations2 2-3 Automatic Backlight Off Press ? to select the backlight level (low, high, or off.) In lo
3、w or high, the backlight turns off automatically after a given period. This period is also preset to 15 minutes and can be set to a maximum of 99 minutes from the setup menu. If the period is set to 0, the backlight is on indefinitely and can only be turned off by pressing ? or turning the meter off
4、. Note See Chapter 5 for power off and backlight off setup information. Low Battery Indication A constant battery icon ( ?) in the upper left corner of the display notifies you that the batteries are low and should be replaced. ?Warning To avoid false readings, which could lead to possible electric
5、shock or personal injury, replace the batteries as soon as the battery icon ( ?) appears. A flashing battery icon means that battery failure is imminent. The backlight cannot be used in this condition. MIN MAX and FAST MN MX features turn off. For Model 189, logging and communications also cease. Mo
6、del 187 refer to Chapter 4 for more information. The rotary switch is shown in Figure 2-2. Each position is described in Table 2-1. dB dB ac+dc ac+dc ac+dc ac+dc F nS CLEAR MEM V mA A mV V mV OFF VIEW MEM C A A mA A tc012f.eps Figure 2-2. Rotary Switch Getting Acquainted Pushbuttons2 2-5 Pushbuttons
7、 The buttons activate features that augment the function selected with the rotary switch. The buttons are shown in Figure 2-3 and described in Table 2-2. Use the blue button ( ?) to access functions labeled in blue for some of the rotary switch positions. Table 2-1 defines all blue button functions.
8、 Use the yellow button ( ?) followed by other buttons to access additional features. These features appear in yellow above the appropriate keys. Table 2-2 defines yellow button features. This manual identifies the yellow button feature in parentheses following the button sequence . For example, acti
9、vating the FAST MN MX mode appears as ? ? (FAST MN MX). MIN MAXHOLDREL %msHzRANGE MIN MAXHOLDREL %msHzRANGE AutoHOLDLOGGING SAVECANCEL FAST MN MX SETUP YES NO tc013f.eps Figure 2-3. Pushbuttons The following yellow button features are not available on Model 187: (YES), (NO), (LOGGING), and (SAVE). M
10、odel 187 the last stable reading is displayed. ?Press to start retaining min, max, and average values. Press successively to display max, min, and average values. Press ? ? (CANCEL) to stop. FAST MN MX ? ? Press to start FAST MN MX mode, where min and max values for short duration events are stored.
11、 ?Press to store the present reading as an offset reference; subsequent readings show only the relative difference from this value. Press again to show the difference as a percentage of the reference. LOGGING ? ? Press to start and stop Logging (Model 189). Press ? + ? (CANCEL) to stop. Getting Acqu
12、ainted Pushbuttons2 2-9 Table 2-2. Pushbuttons (cont.) ButtonDescription Yellow Button FunctionDescription ? ? In Setup, increment a digit . In counter functions, select positive pulse slope. In ohms continuity, select beep on open. In VIEW MEM, see Chapter 4 (Model 189). (none) ? ? In Setup, decrem
13、ent a digit . In counter functions, select negative pulse slope. In ohms continuity, select beep on short. In VIEW MEM, see Chapter 4 (Model 189). (none) ?Exit AUTO and enter MANUAL ranging. In MANUAL, select next input range. Press ? ? (CANCEL) to return to AUTO. SAVE ? ? Press to save present read
14、ing (Model 189) ?Successively press for frequency, duty cycle, and pulse width. CANCEL ? ? CANCEL any ? (blue key) function and all other button features. ? ? The blue button. Press to access blue functions on the rotary switch. In Setup, use arrow function ( ?) to select the next digit or item in a
15、 list. (none) Model 187 only 3-1/2 display digits are allowed. Activate FAST MN MX by pressing ? ?. As with regular MIN MAX, you can then press ? to cycle through maximum, minimum, and average primary displays. The meter beeps for any new minimum or maximum value. Exit FAST MN MX by pressing ? (CANC
16、EL) or by turning the rotary switch. A low battery condition (flashing ?) disables FAST MN MX. In ac measurement functions, MAX and MIN values are peak values, AVG is the rms value. This provides the necessary information in one display for calculation of Crest Factor (peak/rms). Due to longer requi
17、red response times, you cannot use FAST MN MX in the following functions: ohms, diode test, conductance, continuity, capacitance, temperature, ac over dc, ac+dc, Hz, duty cycle, and pulse width. tc033f.eps Figure 2-7. Min Max Avg Model 187 blue letters or symbols identify alternative functions. Pres
18、s the blue button to access these alternate functions. Frequency-related functions can be selected (Hz, duty cycle, and pulse width) when the rotary switch is in any volts or amps position. Measuring Voltage Voltage is the difference in electrical potential between two points. The polarity of ac (al
19、ternating current) voltage varies over time, while the polarity of dc (direct current) voltage is constant over time. Ranges available in volts functions are: ? ? 5.0000 V, 50.000 V, 500.00 V, 1000.0 V ? 50.000 mV, 500.00 mV, and 5000.0 mV Readings in the 5000.0 mV range overload (?) near 3000 mV ac
20、 or dc. The 5000.0 mV range overlaps the 5.0000 V range to provide direct reading display for Fluke accessories that have a millivolt output with limits scaled by 1000. For example, the Fluke 80i-1000 Current Clamp provides 1 mV ac per amp measured up to 1000 amps. Model 187 autoranging is not avail
21、able. Refer to Figure 3-6 for continuity testing setup instructions. Making Measurements Using Conductance for High Resistance Tests3 3-9 Continuity testing provides you with both a visual indication of the state encountered (usually near 0 resistance for a short or OL for an open) and an audible be
22、ep when the input is low. In continuity, a short means a measured value less than 5% of full scale. You can raise this threshold by manually selecting a higher range. You can select whether the beeper comes on for open or short conditions, as follows: Press ? to enable the beeper for opens. Press ?
23、to enable the beeper for shorts. The Hz ( ?) and FAST MN MX ( ? ?) functions are not available when continuity is selected. All other pushbutton functions are available. The blue key cycles among resistance, continuity, and conductance. Using Conductance for High Resistance Tests Conductance, the in
24、verse of resistance, is the ability of a circuit to pass current. High values of conductance correspond to low values of resistance. The unit of conductance is the Siemens (S). The meters 50 nS range measures conductance in nanosiemens (1 nS = 0.000000001 Siemens). Because such small amounts of cond