FLUKE 5700a___omeng0200 电路图.pdf
《FLUKE 5700a___omeng0200 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE 5700a___omeng0200 电路图.pdf(336页珍藏版)》请在收音机爱好者资料库上搜索。
1、 5700A/5720A Series II Multi-Function Calibrator Operators Manual PN 601622 May 1996 Rev. 2, 3/05 1996, 2002, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. RadioFans.CN 收音机爱 好者资料库 LIMITED WARRANTY the display shows line
2、arity, offset, and scale errors Keys that multiply and divide the output value by 10 to simplify work on meters with calibration points at decade multiples of a fraction of full-scale Programmable entry limits used for restricting the levels that can be keyed into the calibrator, preventing access t
3、o levels that may be harmful to equipment or personnel A s key that provides the capability of displaying the instruments specification at the selected operating point, calibration interval, and specification confidence level An auxiliary current binding post that allows you to calibrate meters with
4、 separate current inputs without moving cables Real-time clock and calendar for date stamping reports Offset and scaling modes that simplify linearity testing of multimeters Variable phase reference signal output and phase-lock input Interface for the Fluke 5725A Amplifier Standard IEEE-488 (GPIB) i
5、nterface, complying with ANSI/IEEE Standards 488.1- 1987 and 488.2-1987 Selectable normal remote mode or emulation of the Fluke 5100B and 5200A Series calibrators in functions and response to system controller software EIA Standard RS-232C serial data interface for printing, displaying, or transferr
6、ing internally-stored calibration constants, and for remote control of the calibrator Extensive internal self-testing and diagnostics of analog and digital functions 5700A/5720A Series II Operators Manual 1-4 A traceable calibration procedure for all modes and ranges that requires only 10 V, 1 , and
7、 10 k external standards, with only occasional independent verification Fast, simple, automated calibration check providing added confidence between calibration recalls, and data that can be used to document and characterize the calibrators performance between calibration recalls 1-2. Instruction Ma
8、nuals The 5700A/5720A Series II Calibrators ship with a complete manual set that contains information for the operator and service or maintenance technicians. The set includes: 5700A/5720A Series II Getting Started Manual (PN 1668111) 5700A/5720A Series II Operator Reference Guide (PN 601648) 5700A/
9、5720A Series II Remote Programming Reference Guide (PN 601655) 5700A/5720A Series II Operator Manual (provided on CD-ROM, PN 1668127, or a printed copy is available for purchase through the Fluke Service Department under PN 601622) 5700A/5720A Series II Service Manual (provided on CD-ROM, PN 1668127
10、, or a printed copy is available for purchase through the Fluke Service Department under PN 105798) Order additional copies of these instruction manuals separately using the part numbers provided. For ordering instructions, refer to the Fluke Catalog or contact a Fluke sales representative. 1-3. Abo
11、ut this Manual This manual provides complete information for installing the calibrator and operating it from the front panel keys and in remote. It also provides a glossary of calibration-related terms as well as general items such as specifications and error code information. The following topics a
12、re covered in this manual: Installation Operating controls and features Front panel operation Remote operation (IEEE-488 bus or serial port remote control) Serial port operation (printing, displaying, or transferring data, and setting up for serial port remote control) Operator maintenance, includin
13、g how to calibrate the 5700A/5720A Series II Calibrator Options and accessories Introduction and Specifications How to Use this Manual 1 1-5 1-4. How to Use this Manual Use the following list to find the location of specific information. Unpacking and setup: Chapter 2 Installation and rack mounting:
14、 Chapter 2; also the rack mount kit instruction sheet AC line power and interface cabling: Chapter 2 Controls, indicators, and displays: Chapter 3 Front panel operation: Chapter 4 Cabling to a UUT (Unit Under Test): Chapter 4 Using auxiliary amplifiers: Chapter 4 Self calibration: Chapters 1 and 7 R
15、emote operation (IEEE-488 or serial): Chapter 5 Options and accessories: Chapters 2 and 8 Instrument specifications: The end of this Chapter 1-5. Wideband AC Voltage Module (Option 5700A-03) The Wideband AC Voltage Module (Option 5700A-03) can be installed in both the 5700A and 5720A Series II Calib
16、rators. The module is a high-accuracy, low-noise, extremely flat ac voltage source for calibrating rf voltmeters, with a frequency range of 10 Hz to 30 MHz. Output is in seven ranges from 300 V (-57 dBm) to 3.5 V (+24 dBm) through a Type-N coaxial connector into a 50 load. The output level is select
17、ed in volts or dBm through either the front panel controls or under remote control. The wideband module also functions with the calibrators output adjust controls that let display the error of a wideband meter in either percentage of output or in decibels. Included with the wideband module is a Type
18、-N output cable and a 50 terminator. The wideband module is calibrated to the end of its standard-equipment output cable. 1-6. Auxiliary Amplifier The Fluke Model 5725A Amplifier is available to extend the high voltage performance and current range of the calibrator: Interface connectors on the cali
19、brators rear panel accept cables to directly operate a 5725A. Three amplifiers can be connected to the calibrator at the same time, but only one output can be active at a time. Once you have connected the amplifiers and configured the calibrator in a setup menu, amplifier operation is controlled by
20、the calibrator. Chapter 4 provides instructions for operating the 5725A. The general specifications at the end of this chapter include specifications for operating the calibrator with the 5725A. For other amplifier specifications, refer to their instruction manuals. Table 1-1 summarizes the extended
21、 capabilities offered by the 5725A. Brief descriptions of the extended capabilities follow. 5700A/5720A Series II Operators Manual 1-6 Table 1-1. Auxiliary Amplifier Data Model Mode Range 5725A Amplifier AC V 20 to 1100 V rms up to 70 mA, 40 Hz to 30 kHz (50 mA 5 kHz) 220 to 750 V rms up to 70 mA, 3
22、0 kHz to 100 kHz DC Amps 0 to 11 A DC Amps 1 to 11 A rms, 40 Hz to 10 kHz 1-7. 5725A Amplifier The Fluke 5725A Amplifier is an external unit operating under calibrator control to extend ac voltage drive capabilities and both ac and dc current output range. The amplifier adds the following capabiliti
23、es to the calibrators 1100 V AC range with no compromise in accuracy: Frequency limits at higher voltage increase to 100 kHz at 750 V, 30 kHz at 1100 V. Load limit increases to 70 mA for frequencies above 5 kHz. Capacitive drive increases to 1000 pF, subject to the maximum output current. Extended-p
24、erformance voltage is available at the calibrators front or rear binding posts, eliminating the need to change cables during a procedure. A separate set of binding posts on the front panel of the 5725A supplies extended-range ac and dc current outputs. Since most meters have a separate input termina