BK PRECISION 2650 Instruction 电路图.pdf
《BK PRECISION 2650 Instruction 电路图.pdf》由会员分享,可在线阅读,更多相关《BK PRECISION 2650 Instruction 电路图.pdf(11页珍藏版)》请在收音机爱好者资料库上搜索。
1、Handheld 3.3GHz Spectrum Analyzer 2650 Optimum for evaluation of W-CDMA CDMA GSM PDC PHS Wireless LAN Bluetooth RadioFans.CN 收音机爱 好者资料库 1 RadioFans.CN 收音机爱 好者资料库 2 ? ? ? ? FEATURES2650 ? ? ? ? ? 1 Compact and lightweight 3.75 lb (1.7 kg) The dimensions are as small as WxHxD 6.4 x 2.75 x 10.25” (162
2、x 70 x 260 mm), and the weight is only 3.75 lb (1.7 kg) including the battery. It is very convenient for outdoor use and while on business trips. 2 Measuring frequency range 50kHz to 3.3GHz This bandwidth covers those of W-CDMA, CDMA, PDC, PHS, GSM, 2.4GHz band wireless LAN, Bluetooth. 3 Operation w
3、ith battery for 100 minutes When the battery is fully charged, Model 2650 operates for about 100 minutes (with the back light turned off). It is extremely convenient for outdoor use and for measuring wireless LAN installation environment. 4 Performance that is comparable to large- size bench type Mo
4、del 2650 guarantees a highly stable frequency axis by PLL synthesizer system. The center frequency setting resolution is 100kHz. Furthermore, the average noise level of -110dBm (typical) provides a wide dynamic range and the reference level can be set in 1 dB step. 5 Abundant functions Measuring fun
5、ctions Channel power measurement Adjacent channel power measurement Occupied bandwidth measurement Electric field strength measurement Magnetic field strength measurement Calculation functions MAX HOLD MIN HOLD AVERAGE OVER WRITE Marker and peak search Save / Load Electric field strength meas. Optim
6、um for measurement of cellular phone and wireless LAN working environment. Magnetic field strength meas. Optimum for EMI design of PCBs and for evaluation of signal quality. 6 Auto tuning The center frequency is set at the spectrum of the maximum level in the 3.3GHz band, and in addition, optimum re
7、ference level, resolution bandwidth, video bandwidth and sweep time are set when the AUTO TUNE key is pressed. This function is very convenient for measurement of an unknown signal. 7 Auto range operation The resolution bandwidth, video bandwidth and sweep time are automatically set based on the fre
8、quency span. It is also possible to set auto range operation only one or two out of resolution bandwidth, video bandwidth and sweep time. 8 Hard copy of the image Connect a printer (PT 2650 optional) and press the PRINT key on Model 2650. The image on the screen is printed as it is. 9 High resolutio
9、n display on the PC screen The spectrum waveform is displayed at high resolution, 1000 points in the horizontal axis, on the PC screen when PC Software AK 2650 (optional) is used. Model 2650 is a compact, lightweight, high per- formance spectrum analyzer that provides signal analysis and functionali
10、ty comparable to larger bench type models. RadioFans.CN 收音机爱 好者资料库 3 Measuring functions2650 Channel power measurement Measures the sum of the power in the zone specified by the zone center and zone width (slash area in figure). In short, it is possible to measure the total power in the specified fr
11、equency band. Of course it is possible to measure the noise power. Adjacent channel power measurement Capable of measuring the adjacent channel power leakage as the ratio of the power in the range specified by offset frequency and bandwidth (slash area in figure) to the carrier wave power. Both the
12、upper and lower side power leakage are measured. Furthermore, the method for meas- urement may be selected out of three methods, i.e., total power method, reference level method and in- band method, from the classification of definition of carrier wave power. Magnetic field strength measurement Mode
13、l 2650 is capable of precisely measuring the magnetic field distribution on an LSI or a printed circuit board using magnetic field probe PR 26M (optional) As the magnetic field detection portion of PR 26M is of a shield- ed loop structure that adopts glass ceramic multi-layer board technology of exc
14、ellent high frequency characteristics, it is pos- sible to take measurement at high reproducibility by detecting magnetic field components only. The measuring frequency range is as broad as 10MHz to 3GHz, and the measured value is calibrated in the instrument. Evaluation of effectiveness of the bypa
15、ss capacitor located at the power supply terminal of an LSI and evaluation of wiring rule on a printed circuit board can be raised as typical use of PR 26M. PR 26M is not affected by adjacent patterns because of high space resolution. Occupied bandwidth measurement It is possible to measure the occu
16、pied frequency bandwidth as the bandwidth of the point that is lower by X (dB) than the peak level or as the bandwidth of the point of Y (%) of the total power. 4 Electric field strength measurement It is possible to measure the electric field strength by connecting dipole antennas (optional) to the
17、 input connector. A dipole anten- na that suits the use is available. AN301 is mainly for PDC 800MHz and GSM 900MHz band, AN302 is mainly for PDC 1500MHz band, AN303 is mainly for PHS, W-CDMA and GSM 1800 / 1900MHz band, and AN304 is mainly for 2.4GHz wire- less LAN and Bluetooth. AN304 is capable o
18、f measuring direct sequence spread spectrum, frequency hopping and Bluetooth system by 10 ms sweep time and MAX HOLD function. Measuring functions2650 The conventional method cover- ing low frequency through high frequency with a single antenna results in low antenna gain because of using a range de
19、viat- ing from the antenna resonance point, and the dynamic range largely worsens as a result. Model 2650, however, provides an antenna for each frequency band and uses a resonance point of high gain only, and accordingly, it is capable of securing a wide dynamic range. Antennas of other bands will
20、be also pre- pared if requested. As the electric field strength is calibrated for each antenna in Model 2650, it is possible to directly read the measured value. 5 Marker and peak search2650 Marker measurement Two different modes are available for marker measurement. One is normal marker mode to mea
21、sure and display the fre- quency (maximum effective number of digits : 7) and level (max- imum effective number of digits : 3) of the marker point, and another is delta marker mode to measure and display the fre- quency difference and level difference between two markers (one of which is a reference
22、 marker). Normal peak search Zone peak search Peak search Two different modes are available for peak search. One is nor- mal peak search mode to search for the peak level with all of 10div of the frequency axis as the search range, and another is in-zone peak search mode to search for the peak level
23、 in the range specified by the center value and width. NEXT search (search for the next smaller level) of up to 9 is permitted in the normal peak search mode. The marker moves to the peak level at each sweep in the in-zone peak search mode. Normal marker measurement Delta marker measurement 6 Auto t
24、uning2650 Auto range2650 Save / Load2650 The search for the signal of the maximum level in the 3.3GHz band is executed and the result is displayed in the specified fre- quency span when the AUTO TUNE key is pressed. The spec- trum is tuned to the vicinity of the center of the screen, and the referen
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BK PRECISION 2650 Instruction 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf