Biddle DET62D_UG 电路图.pdf
《Biddle DET62D_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle DET62D_UG 电路图.pdf(12页珍藏版)》请在收音机爱好者资料库上搜索。
1、DIGITAL EARTH TESTER MEGGERDET62D User Guide MeterCenter www.MeterC (800) 230-6008 NOTE THE INSTRUMENT MUST ONLY BE USED BY TRAINED AND COMPETENT PERSONS. GENERAL DESCRIPTION. The MEGGER DET62D Digital Earth Tester is a compact portable instrument designed to measure earth electrode resistance quick
2、ly and accurately. Powered by six LR6 battery cells, the instrument is very robust and has a tough case moulded in ABS plastic. The instrument uses the three-terminal method of measurement in which the X terminal is connected to the earth electrode under test, and the C and P terminals are connected
3、 to Current and Potential test spikes. Test frequency is 128 Hz to avoid problems from electrical mains Noise. Test leads and auxiliary electrode test spikes can be supplied as part of an earth testing field accessory kit which is available as an option. SAFETY WARNINGS Warnings and precautions must
4、 be read and understood before the instrument is used. They must be observed during use. The earth spikes, test leads and their terminations must not be touched if an installation earth-fault can arise, unless adequate precautions are taken. The DET62D must be disconnected while its battery cells ar
5、e changed. Replacement fuses must be of the correct type and rating. Special precautions are necessary when live earths may be encountered. Isolation switches and fuses are needed in this situation. When working near high tension systems, rubber gloves and shoes should be worn. RadioFans.CN 收音机爱 好者资
6、料库 DET62D FEATURES CIRCUIT CONDITION WARNING INDICATORS IF ANY OF THE WARNING INDICATION LEDS ARE ILLUMINATED, A WARNING ALERT ARROW IS DISPLAYED . HIGH CURRENT SPIKE RESISTANCE (Rc) During a test, if the resistance of the Current circuit is too high for accurate measurement, the Rc LED automaticall
7、y illuminates. This may be caused by an open circuit, poor test lead connections, or excessive resistance of the soil near the electrode under test and / or the remote Current spike. Whatever the cause of the symbols appearance, it should be cleared before a test can be regarded as valid. Moistening
8、 the soil around the Current spike; re-siting the spike in a new position or using more than one spike may solve the problem. HIGH POTENTIAL SPIKE RESISTANCE (Rp) If the resistance of the Potential circuit is too high for an accurate measurement, the Rp LED automatically illuminates. This may be cau
9、sed by an open circuit, poor test lead connections, or excessive resistance of the soil near the electrode under test and / or the remote Voltage spike. Whatever the cause of the symbols appearance, it should be cleared before a test can be regarded as valid. Moistening the soil around the Voltage s
10、pike; re-siting the spike in a new position or using more than one spike may solve the problem. EXCESSIVE NOISE INTERFERENCE (NOISE / BRUIT) During a test, if the interference voltage in the earth being measured is beyond the level that can be rejected by the Instrument, the NOISE LED will illuminat
11、e. Valid measurements cannot be made in this condition, and the solution may be to wait until the interference has subsided. Alternatively, choose a new position for the two remote test spikes, by re-siting them at right angles to their first position; still in a straight line, and try again. XPC ES
12、H EARTH TESTER EARTH TESTER R D D The 312digit liquid crystal display shows all test resistance results directly in or k, with the decimal point automatically Warning LEDs (accompanied with Warning Alert arrow) indicate any excessive resistance in the Current circuit, or the Potential circuit (both
13、usually caused by a high test spike resistance) and any excessively Noisy earth environment Single push button operation. All other functions are automatic Low battery voltage indicator If the resistance under test exceeds 2 k, an over-range symbol appears (1 as left hand digit, with a decimal point
14、) Battery compartment cover Range indicators Electrode under test terminal Potential test spike terminal Current test spike terminal Case protected to IP54 Warning Alert arrow RadioFans.CN 收音机爱 好者资料库 APPLICATIONS The principal application of the DET62D is in the testing of single or small earth elec
15、trodes by the 3 terminal test technique. The instrument will directly measure the resistance to earth of an earth electrode, in the presence of electrical mains supply noise in the soil, provided it is not excessive. The instrument may also be used equally well for the testing of Continuity of condu
16、ctors; conduit coupling joints etc. MEASURING METHOD - 3 TERMINAL RESISTANCE MEASUREMENT A measured current is passed between the electrode under test X, and the remote Current electrode C. The voltage drop between X, and the remote potential electrode P is measured. The resistance of the electrode
17、under test is then the voltage between X and P, divided by the current flowing between X and C, provided there is no overlap of the resistance areas of the electrodes. The resistance area is where the incremental resistance is still significant, owing to localised current flows. V By Ohms Law: R = I
18、 THE FALL OF POTENTIAL METHOD This is the basic method for measuring the resistance of earth electrode systems. It is most useful on small single or double earth electrode systems. To obtain a reliable measurement with the Fall-of-Potential method the Current spike must be far enough away from the E
19、arth electrode. In general, reliable results may be expected if the distance between the Current spike and the Electrode under test is at least ten times the maximum dimension of the electrode system, e.g. 30 m for a 3 m electrode system. Both possess resistance areas, and if they are positioned too
20、 close together their resistance areas will overlap. The optimum position for the Potential spike will be located between these resistance areas. To locate this point the Potential spike is moved between X and C, and readings are taken at each location. The more readings that are taken, the more acc
21、urate the final resistance reading will be. Test results are plotted, on a curve. The optimum position is the point on the curve where reading variation is minimal. Provided there is reasonable homogeneity of the soil, the distance apart is adequate, and the straight line of the electrodes is mainta
22、ined, the shape of the curve will ideally be as shown. OPERATION INITIAL TEST SET UP AND CONNECTIONS 1. Connect a short lead from the Earth electrode to be tested to the instrument terminal X (E) (The resistance of this lead will be included in the measurement). 2. Insert the Current test spike into
23、 the ground 30 to 50 metres away from the Earth electrode to to be tested. Connect this spike to the instrument terminal C (H). 3. Insert the Potential test spike into the ground midway between the Current test spike and the Earth electrode, and in direct line with them both. Connect this spike to t
24、he instrument terminal P (S). 4. When running the test leads out to each remote electrode, avoid laying the wires too close to each other. ? ? ? ? A V XPC Auxiliary Current Electrode Auxiliary Potential Electrode Electrode Under Test CURRENT SOURCE Resistance Areas (Not Overlapping) Auxiliary Curren