FLUKE PM6666__omeng0000 电路图.pdf
《FLUKE PM6666__omeng0000 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE PM6666__omeng0000 电路图.pdf(46页珍藏版)》请在收音机爱好者资料库上搜索。
1、CONTENTS SAFETY.4 Introduction.4 PRODUCT PRESENTATION .5 INSTALLATION .7 Unpacking.7 Voltage-range selection .7 Grounding.8 Connecting external reference.8 Installing options.8 Calibrating the MTCXO.8 OPERATING INSTRUCTIONS .10 Using the Timer/counter.10 Battery unit .22 Error codes .22 GPIB-INTERFA
2、CE OPERATION.23 Introduction.23 What can I do using the bus? .23 Connecting the controller.24 Giving the counter an address.24 Checking the communication.24 Two ways of programming .25 Syntax.25 Selecting output separator.26 How to select function.26 Selecting Measuring-Time. 27 Selecting Input sett
3、ings . 27 Totalize Start/Stop . 27 Free-Run/Triggered. 28 Service Request. 28 Status byte. 29 Output mode. 29 Bus Learn. 31 Programming data out. 31 What happens when I switch to local? . 32 Summary of bus commands. 32 Programming Examples . 33 SPECIFICATIONS. 37 Measuring functions . 37 Input speci
4、fications. 38 Auxiliary functions. 39 Definitions. 39 General information. 40 Optional accessories. 41 Ordering information . 42 APPENDIX . 43 Checking the sensitivity of counters . 44 INDEX. 45 4822 872 20017 7/October 1996 CONTENTSPage: 1 PM 6666 - OPERATORS MANUAL RadioFans.CN 收音机爱 好者资料库 DECLARAT
5、ION OF CONFORMITY for FLUKE Timer / Counter PM 6666 Fluke Industrial B.V. Lelyweg 1 7602 EA Almelo The Netherlands Statement of Conformity Based on test results using appropriate standards, the product is in conformity with Electromagnetic Compatibility Directive 89/336/EEC Low Voltage Directive 73/
6、23/EEC Sample tests Standards used: IEC 348 (1978) Safety Requirements for Electronic Measuring Apparatus EN 50081-1 (1992) Electromagnetic Compatibility Generic Emission Standard: EN55011 EN 50082-1 (1992) Electromagnetic Compatibility Generic Immunity Standard: IEC801-2, -3, -4 The tests have been
7、 performed in a typical configuration. This Conformity is indicated by the symbol, i.e. “Conformit europenne”. DMB70-08-95206 Page: 2CONTENTS PM 6666 - OPERATORS MANUAL RadioFans.CN 收音机爱 好者资料库 Guarantee Statement This Fluke guarantee is in addition to all rights which the buyer may have against his
8、supplier under the sales agreement be- tween the buyer and the supplier and according to local legislation. Fluke guarantees this product to be free from defects in material and workmanship under normal use and service for a pe- riod of one (1) year from the date of shipment.This guarantee does not
9、cover possible required re-calibration and/or stand- ard maintenance actions. This guarantee extends only to the original end purchaser and does not apply to fuses, batteries or to any product or part thereof that has been misused, altered, or has been subjected to abnormal conditions of operation a
10、nd handling. Fluke-supplied software is guaranteed to be properly recorded on non-defective media.We will replace improperly recorded media without charge for 90 days after shipment upon receipt of the software. Our software is not guaranteed to be error free. Flukeobligation under this guarantee is
11、 limited to have repaired or replace a product that is returned to an authorized Fluke Service Center within the guarantee period, provided that Fluke determines that the product is defective and that the failure has not been caused by misuse, alteration or abnormal operation. Guarantee service for
12、products installed by Fluke will be performed at the Buyers facility at no charge within Flukeservice travel area; outside this area guarantee service will be performed at the Buyers facility only upon Fluke prior agreement and the Buyer shall pay Fluke round trip travel expenses. If a failure occur
13、s, send the product, freight prepaid, to the Service Center designated by Fluke with a description of the diffi- culty. At Flukeoption, repairs will be made or the product replaced. Fluke shall return the product, F.O.B. Repair Center, trans- portation prepaid, unless the product is to be returned t
14、o another country, in which case the Buyer shall pay all shipping charges, duties, and taxes. Fluke assume NO risk for damage in transit. Disclaimer The foregoing guarantee is exclusive and is in lieu of all other guarantees, expressed or implied, including but not limited to any implied guarantee o
15、f merchantability, fitness, or adequacy for any particular purpose or use. We shall not be liable for any direct, indirect, special incidental, or consequential damages, whether based on contract, tort, or otherwise. CONTENTSPage: 3 PM 6666 - OPERATORS MANUAL RadioFans.CN 收音机爱 好者资料库 SAFETY Introduct
16、ion Read this page carefully before you install and use the PM 6666 Timer/Counter. This Timer/Counter has been designed and tested in ac- cordance with IEC publication 1010-1, and CSA 22.2 No.231, and has been supplied in a safe condition.The user of this instrument must have the required knowledge
17、of PM 6666.This knowledge can be gained by thoroughly studying this manual. Safety Precautions Use generally-accepted safety procedures, in addition to the safety precautions stated in this manual, to ensure per- sonal safety and safe operation of the Timer/Counter. Caution See GPIB-bus operation. C
18、onnect the signal to INPUT-A via a BNC- cable. Connect the signal to INPUT-B via a BNC- cable. LOCAL RESET START/STOP TOTALIZE A HOLD DISPLAYMEASURING TIME 10s1s0.2sSINGLEREF EXT MAN TOT A B TOT A B TOT A A-B TIME A/B RATIO A PERIOD C FREQ A FREQ FUNCTION COMMON B via A VOLT A MAX-MIN LEVEL AUTO LEV
19、EL READ HOLD DISPL HOLD DISPLAYMEASURING TIME 10s1s0.2sSINGLEREF EXT MAN TOT A B TOT A B TOT A A-B TIME A/B RATIO A PERIOD C FREQ A FREQ FUNCTION COMMON B via A VOLT A MAX-MIN LEVEL AUTO LEVEL READ DC 160MHz 35pF 1M MAX 30Vrms A B 35pF 1M MAX 30Vrms Page: 16OPERATING INSTRUCTIONS PM 6666 - OPERATORS
20、 MANUAL FUNCTION AND RANGEHINTS AND COMMENTS When reset is depressed, the display and counting registers are cleared. When reset is released, a new measurement is started. The Measuring-time-, Function- and display hold- settings are not affected. If the TOT A MAN function is selected, the RESET/LOC
21、AL button functions as a START/STOP button. One press starts the counting and the next press stops it. A long de- pression results in reset. When the counter is controlled from the GPIB-Bus, the LOCAL button can be disabled via the Local Lock out command. Display hold freezes the display, but not un