1、4822 872 05375 August 1997, Rev. 3, 01/00 1997 Fluke Corporation. All rights reserved. Printed in the Netherlands All product names are trademarks of their respective companies. 123 Industrial ScopeMeter Service Manual RadioFans.CN 收音机爱 好者资料库 SERVICE CENTERS To locate an authorized service center, v
2、isit us on the World Wide Web: or call Fluke using any of the phone numbers listed below: +1-888-993-5853 in U.S.A. and Canada +31-402-678-200 in Europe +1-425-356-5500 from other countries RadioFans.CN 收音机爱 好者资料库 Table of Contents ChapterTitlePage 1Safety Instructions. 1-1 1.1 Introduction. 1-3 1.2
3、 Safety Precautions. 1-3 1.3 Caution and Warning Statements. 1-3 1.4 Symbols. 1-3 1.5 Impaired Safety. 1-4 1.6 General Safety Information. 1-4 2Characteristics . 2-1 2.1 Introduction. 2-3 2.2 Dual Input Oscilloscope. 2-3 2.2.1 Vertical . 2-3 2.2.2 Horizontal. 2-4 2.2.3 Trigger . 2-4 2.2.4 Advanced S
4、cope Functions. 2-5 2.3 Dual Input Meter. 2-5 2.3.1 Input A and Input B. 2-5 2.3.2 Input A. 2-8 2.3.3 Advanced Meter Functions. 2-8 2.4 Miscellaneous . 2-9 2.5 Environmental. 2-10 2.6 Service and Maintenance. 2-11 2.7 Safety . 2-11 2.8 EMC Immunity . 2-12 3Circuit Descriptions . 3-1 3.1 Introduction
5、. 3-3 3.2 Block Diagram. 3-3 3.2.1 Channel A, Channel B Measurement Circuits. 3-4 3.2.2 Trigger Circuit. 3-4 3.2.3 Digital Circuit. 3-5 3.2.4 Power Circuit. 3-6 3.2.5 Start-up Sequence, Operating Modes. 3-7 RadioFans.CN 收音机爱 好者资料库 123 Service Manual 3.3 Detailed Circuit Descriptions. 3-9 3.3.1 Power
6、 Circuit. 3-9 3.3.2 Channel A - Channel B Measurement Circuits . 3-15 3.3.3 Trigger Circuit. 3-20 3.3.4 Digital Circuit. 3-25 4Performance Verification. 4-1 4.1 Introduction. 4-3 4.2 Equipment Required For Verification . 4-3 4.3 How To Verify. 4-3 4.4 Display and Backlight Test. 4-4 4.5 Input A and
7、Input B Tests. 4-5 4.5.1 Input A and B Base Line Jump Test. 4-6 4.5.2 Input A Trigger Sensitivity Test. 4-7 4.5.3 Input A Frequency Response Upper Transition Point Test. 4-8 4.5.4 Input A Frequency Measurement Accuracy Test. 4-8 4.5.5 Input B Frequency Measurement Accuracy Test . 4-9 4.5.6 Input B F
8、requency Response Upper Transition Point Test. 4-10 4.5.7 Input B Trigger Sensitivity Test. 4-10 4.5.8 Input A and B Trigger Level and Trigger Slope Test. 4-11 4.5.9 Input A and B DC Voltage Accuracy Test. 4-14 4.5.10 Input A and B AC Voltage Accuracy Test. 4-15 4.5.11 Input A and B AC Input Couplin
9、g Test. 4-16 4.5.12 Input A and B Volts Peak Measurements Test. 4-17 4.5.13 Input A and B Phase Measurements Test. 4-18 4.5.14 Input A and B High Voltage AC/DC Accuracy Test. 4-19 4.5.15 Resistance Measurements Test. 4-20 4.5.16 Continuity Function Test. 4-21 4.5.17 Diode Test Function Test . 4-22 4
10、.5.18 Capacitance Measurements Test . 4-22 4.5.19 Video Trigger Test. 4-23 5Calibration Adjustment. 5-1 5.1 General. 5-3 5.1.1 Introduction. 5-3 5.1.2 Calibration number and date. 5-3 5.1.3 General Instructions. 5-3 5.2 Equipment Required For Calibration. 5-4 5.3 Starting Calibration Adjustment. 5-4
11、 5.4 Contrast Calibration Adjustment . 5-6 5.5 Warming Up so only one of these functions needs to be verified. 4.2 Equipment Required For Verification The primary source instrument used in the verification procedures is the Fluke 5500A. If a 5500A is not available, you can substitute another calibra
12、tor as long as it meets the minimum test requirements. Fluke 5500A Multi Product Calibrator, including 5500A-SC Oscilloscope Calibration Option. Stackable Test Leads (4x), supplied with the 5500A. 50 Coax Cables (2x), Fluke PM9091 (1.5m) or PM9092 (0.5m). 50 feed through terminations (2x), Fluke PM9
13、585. Fluke BB120 Shielded Banana to Female BNC adapters (2x), supplied with the Fluke 123. Dual Banana Plug to Female BNC Adapter (1x), Fluke PM9081/001. Dual Banana Jack to Male BNC Adapter (1x), Fluke PM9082/001. TV Signal Generator, Philips PM5418. 75 Coax cable (1x), Fluke PM9075. 75 Feed throug
14、h termination (1x), ITT-Pomona model 4119-75. PM9093/001 Male BNC to Dual Female BNC Adapter 4.3 How To Verify Verification procedures for the display function and measure functions follow. For each procedure the test requirements are listed. If the result of the test does not meet the requirements,
15、 the test tool should be recalibrated or repaired if necessary. 123 Service Manual 4-4 Follow these general instructions for all tests: For all tests, power the test tool with the PM8907 power adapter. The battery pack must be installed. Allow the 5500A to satisfy its specified warm-up period. For e
16、ach test point , wait for the 5500A to settle. Allow the test tool a minimum of 20 minutes to warm up. 4.4 Display and Backlight Test Proceed as follows to test the display and the backlight: 1. Press TO TURN THE Test tool on. 2. Press and verify that the backlight is dimmed. Then select maximum bac