FLUKE 80 Series III Service Information 电路图.pdf
《FLUKE 80 Series III Service Information 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE 80 Series III Service Information 电路图.pdf(34页珍藏版)》请在收音机爱好者资料库上搜索。
1、 80 Series III Multimeters Service Information PN 688645 April 1998 Rev.2, 6/02 1998-2002 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. RadioFans.CN 收音机爱 好者资料库 Lifetime Limited Warranty Each Fluke 20, 70, 80, 170 and 180 Ser
2、ies DMM will be free from defects in material and workmanship for its lifetime. As used herein, “lifetime” is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least ten years from the date of purchase. This warranty does not cover fuses,
3、disposable batteries, damage from neglect, misuse, contamination, alteration, accident or abnormal conditions of operation or handling, including failures caused by use outside of the products specifications, or normal wear and tear of mechanical components. This warranty covers the original purchas
4、er only and is not transferable. For ten years from the date of purchase, this warranty also covers the LCD. Thereafter, for the lifetime of the DMM, Fluke will replace the LCD for a fee based on then current component acquisition costs. To establish original ownership and prove date of purchase, pl
5、ease complete and return the registration card accompanying the product, or register your product on . Fluke will, at its option, repair at no charge, replace or refund the purchase price of a defective product purchased through a Fluke authorized sales outlet and at the applicable international pri
6、ce. Fluke reserves the right to charge for importation costs of repair/replacement parts if the product purchased in one country is sent for repair elsewhere. If the product is defective, contact your nearest Fluke authorized service center to obtain return authorization information, then send the p
7、roduct to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Fluke will pay return transportation for product repaired or replaced in-warranty. Before making any non-warranty repair, Fluke will esti
8、mate cost and obtain authorization, then invoice you for repair and return transportation. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMA
9、GES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON FLUKES BEHALF. Since some states do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limita
10、tion of liability may not apply to you. If any provision of this warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. 2/02 RadioFans.CN 收音机爱 好者资料库 i Table of Content
11、s TitlePage Introduction. 1 Precautions and Safety Information. 2 International Symbols. 2 Safety Information. 3 Specifications. 4 Accuracy . 4 General. 4 AC Voltage Specifications (Models 85 and 87). 5 AC Voltage Specifications (Model 83). 5 DC Voltage, Resistance, and Conductance Specifications. 5
12、 Current Specifications. 6 Capacitance and Diode Function Specifications . 6 Frequency Counter Specifications. 6 Frequency Counter Sensitivity and Trigger Levels . 7 MIN MAX Recording Specifications. 7 Electrical Characteristics of the Terminals. 8 Required Equipment. 8 Basic Maintenance . 9 Opening
13、 the Meter Case. 9 Removing and Reinserting the Circuit Board Assembly. 10 Reassembling the Meter Case. 11 Replacing the Battery. 11 Testing Fuses (F1 and F2). 12 Replacing Fuses . 13 Cleaning. 13 Input Terminals. 13 Rotary Switch . 14 Performance Tests. 14 A Basic Operability Test. 14 Testing the D
14、isplay. 15 Testing the Rotary Switch. 15 Testing the AC Voltage Function. 16 Testing the Frequency Function. 17 Testing the Frequency Sensitivity and Trigger Level. 17 Testing DC Voltage . 18 Testing the PEAK MIN MAX Function (Model 87 only). 18 RadioFans.CN 收音机爱 好者资料库 80 Series III Service Manual i
15、i Testing the mV DC Function. 19 Testing the Resistance Function. 19 Testing the Capacitance Function. 20 Checking the Diode Test Function. 20 Testing the Milliamp (mA) Function. 21 Testing the Microamp (A) Function. 21 Testing the Amp (A) Function. 22 Calibration. 23 Calibrating the Model 85 and 87
16、 III. 23 Calibrating the Model 83 III . 25 Parts and Accessories. 25 iii List of Tables TableTitlePage 1.International Symbols. 2 2.Required Tools and Equipment. 9 3.Rotary Switch Test . 16 4.AC Voltage Test. 16 5.Frequency Test. 17 6.Frequency Counter Sensitivity and Trigger Level Tests. 18 7.DC Vo