1、USER GUIDE GUIDE DE LUTILISATEUR BEDIENUNGSANLEITUNG GUIDA PER LUTENTE GUIA DEL USUARIO M DLRO-10 the default is NO. Change this to YES and press Enter if you wish to delete all data. Please note - ALL stored data will be deleted. Storage The Storage option sets the default for data storage. It may
2、be set to always store data or never to store data. Highlight the desired option at the bottom of the screen and press Enter. With the exception of tests carried out in Continuous mode, at the end of each test you have the option to change the default by selecting STORE or NO STORE at the bottom of
3、the results screen. At the end of a test, if memory is full this STORE / NO STORE message will change to MEMORY FULL and no more tests will be stored. Data is stored indefinitely if a charged battery pack is fitted. If the main battery becomes exhausted or is removed, data is maintained for a period
4、 of 4 days by an internal backup battery. When a charged battery pack is refitted, the backup battery will recharge to full capacity within 1 week. Range Menu DLRO 10X uses a test current between 100 A and 10 A to measure the resistance of the item under test. If set to AUTO, DLRO 10X will select th
5、e current according to the resistance it detects. (see Specifications, Ranges) However, in some cases it may be desirable set a maximum test current. If this is so, move the cursor to the desired current and press Enter. Six test currents are available; 10 A, 1 A, 100 mA, 10 mA, 1 mA and 100 A. Sele
6、cting the 10 A maximum will have the same effect as selecting AUTO. The Main Menu screen will show the active current range beneath the RANGE heading. GENERAL OPERATION - DLRO 10X 9 TESTOPTIONS RANGE NORMAUTO DD MM YY HH MM 09/10/00 15.08 DD MM YY 09/10/00 12.02 ENTERING NOTES IN THE MEMO SCREEN At
7、the end of each test, (with the exception of a test in Continuous mode), you can select the STORE or NO STORE option to store the test results or not. Select the desired option using the cursor control. This overrides the default setting under Options, Storage for one test only. If you wish to add c
8、omments to the test results, instead of pressing Enter, briefly press one of the twelve keys on the keypad. You will enter a memo screen that allows you to enter up to 200 characters of alphanumeric information concerning the test. When you have entered all information press Enter and the measuremen
9、t and memo will be stored regardless of whether STORE or NO STORE was selected. If you do not wish to add notes and are happy to accept the default STORE / NO STORE setting you may press the Test button and a new test will be started. TEST RESULT STORAGE Each test is numbered, starting at test 1. Th
10、is test number is incremented automatically, as each result is stored. The test result memory can store a maximum of 700 tests, each being identified by its test number, date and time. It is advisable to retrieve all data to a PC and then to delete all data before the test number reaches this maximu
11、m. Deleting the data will reset the test number to 1. This will save loss of data. KEYPAD OPERATION The 12 key keypad is similar to those used on mobile telephones in that each key is capable of producing one of several characters depending on the number of times the key is pressed. The keypad is us
12、ed to enter data into the Memo field. Pressing the blue key marked 9/A changes the function of the keyboard between alpha and numeric modes. In alpha mode a full height flashing vertical bar (|) indicates the cursor. The keys 2 to 9 will produce the letter shown on the keys depending on the number o
13、f presses. For example if the 2 key is pressed once an A will appear, twice and a B will appear etc. The 0 key produces a space. The 1 key is a destructive backspace. In numeric mode a half height flashing bar () indicates the cursor. The keys marked 1 - 9 and 0 produce that number when pressed. Pre
14、ss the respective key briefly to enter the desired number. Pausing will cause the cursor to move on to the next character. If a key is held down it will auto-repeat. The key at the bottom right hand corner of the keypad marked with a dot is a special key that produces 20 special symbols. Each press
15、will sequentially produce the character shown on next page: GENERAL OPERATION DLRO 10X 10 .Decimal point or full stop Ohms symbol mlower case m (abbreviation for milli) Symbol for micro #Symbol known as hash or pound and commonly used as shorthand for number %Percent sign (Left round bracket )Right
16、round bracket -Hyphen, dash or minus sign / Slash :Colon at symbol; Tick mark !Exclamation mark ?Question mark $Dollar symbol =Equals sign Greater than symbol *Asterisk GENERAL OPERATION DLRO 10X 11 TEST MODES DLRO 10 has 4 test modes which are selected by repeated presses of the Mode button. At the
17、 end of each test, DLRO 10 will display the average of the values obtained with forward and reverse current. DLRO 10X has 5 modes. On DLRO 10X these modes are selected from the TEST menu using the cursor control and Enter key. At the end of a test, DLRO 10X will show three resistance values; that ob
18、tained with forward current, that obtained with reverse current and the average value. Normal mode Normal mode makes a single measurement of the resistance of the sample using forward and reverse current Please note that in this mode both the current and voltage leads must be connected across the te
19、st sample before the Test button is pressed. To make another measurement, ensure the test leads are connected and press the test button. Automatic mode If Automatic mode is selected, your instrument will remain in a state of readiness waiting for both the current AND voltage measuring leads to be co
20、nnected to the test piece. When this is done, a forward and reverse current test will be started automatically. To make another measurement simply break contact with the test sample and remake contact. For example, if measuring joints in a long bus bar, you may leave the current circuit connected at
21、 opposite ends of the bus bar. Simply making contact with voltage probes across the joint(s) you wish to measure will then activate the measurement. Continuous mode Continuous mode requires the connections to be made before pressing the Test button. Your instrument will then repeat its forward and r
22、everse measurements and display the results approximately every 3 seconds until contact is broken or the Test button is pressed. Inductive mode DLRO 10 and DLRO 10X are able to make d.c. resistive measurements on loads that exhibit an inductive component using the test mode indicated by the inductor
23、 symbol on the DLRO 10, or by using the inductive mode on the DLRO 10X. When measuring inductive loads it is essential that the current carrying leads are securely clamped to the item being tested and that they are not removed before any stored charge has been discharged at the end of the test. Fail
24、ure to comply with these instructions might result in an arc being produced, which might be dangerous for the instrument and the operator. Having selected inductive mode, connect all four leads to the item being tested and press the Test button. DLRO will check that all four leads are in adequate co
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle dlro-10-10x_user_manual 电路图 dlro 10 x_user_manual
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
Hammond M_freq_charts.zip
Hammond D100_schem_main.gif
tubalizeriz0.jpg
Hammond generator-qst1944-01.djvu