PHILIPS. PM3295. Test. Service Manual. CDC-311.电路图.pdf
《PHILIPS. PM3295. Test. Service Manual. CDC-311.电路图.pdf》由会员分享,可在线阅读,更多相关《PHILIPS. PM3295. Test. Service Manual. CDC-311.电路图.pdf(322页珍藏版)》请在收音机爱好者资料库上搜索。
1、350 MHzVHF Dual Channel, Dual Time Base Osci I loscope PM3295 Service Manual 482287205305 860207/2/01 PH I LI PS RadioFans.CN 收音机爱 好者资料库 1. SAFETY INSTRUCTIONS Read these pages carefully before installation and use of the instrument. 1.1. INTRODUCTION The following clauses contain information, cauti
2、ons and warnings which must be followed t o ensure safe operation and to retain the instrument i n a safe condition. Adjustment, maintenance and repair of the instrument shall be carried out only by qualified personnel. 1.2. SAFETY PRECAUTIONS For the correct and safe use of t h i s instrument it is
3、 essential that both operating and servicing personnel follow generally-accepted safety procedures i n addition t o the safety precautions specified in t h i s manual. Specific warning and caution statements, where they apply, w i l l be found throughout the manual. Where necessary, the warning and
4、caution statements.and/or symbols are marked on the apparatus. 1.3. CAUTION AND WARNING STATEMENTS CAUTION: is used t o indicate correct operating or maintenance procedures i n order to prevent damage to or destruction of the equipment or other property. WARNING: calls attention to a potential dange
5、r that requires correct procedures or practices i n order to prevent i n order t o prevent personal injury. 1.4. SYMBOLS f High voltage - 1000 V (red 1 A Live part Read the operating A instructions. (black/ yellow) Protective earth (black) 0 (grounding) terminal RadioFans.CN 收音机爱 好者资料库 1-2 1.5. IMPA
6、IRED SAFETY-PROTECTION 1.6. 1.6.1. 1.6.2. 1.6.3. 1.6.4. 1.6.5. 1.6.6. Whenever it is likely that safety-protection has been impaired, the instrument must be made inoperative and be secured against any unintended operation. The matter should then be referred to qualified technicians. Safety protectio
7、n is likely to be impaired if, for example, the instrument fails to perform the intended measurements or shows visible damage. GENERAL CLAUSES WARNING: The opening of covers or removal of parts, except those to which access can be gained by hand, is likely to expose live parts and accessible termina
8、ls which can be dangerous to live. The instrument shall be disconnected from all voltage sources before it is opened. Bear in mind that capacitors inside the instrument can hold their charge even if the instrument has been separated from all voltage sources. WARNING: Any interruption of the protecti
9、ve earth conductor inside or outside the instrument, or disconnection of the protective earth terminal, is likely to make the instrument dangerous. Intentional interruption is prohibited. Components which are important for the safety of the instrument may only be renewed by components obtained throu
10、gh your local Philips organisation. (See also section 27). After repair and maintenance in the primary circuit, safety inspection and tests, as mentioned in Section 27 have to be performed. RadioFans.CN 收音机爱 好者资料库 2. 2.1. GENERAL IVFORMATION INTRODUCTION TO THE PX 3295 OSCILLOSCOPE. This compact V.H
11、.F. o s c i l o s c o p e features an extensive bandwidth of 350 MHz and good ergonomic design for its numerous measurement c a p a b i l i t i e s . A unique f e a t u r e is the AUTO SET pushbutton f a c i l i t y , which automatically sets Various controls of the instrument to s u i t the input s
12、ignal value. In t h i s way, optimum ease of operation is obtained a s the input signal immediately presents a correct, stable display on the bright c.r.t. screen. The microprocessor-controlled front panel gives a wide choice of display p o s s i b i l i t i e s . Fig. 2.1. 350 MHz V.H.F. oscillosco
13、pe PM3295. The oscilloscope is provided with integrated c i r c u i t s (including thin- film c i r c u i t s ) , which guarantee highly-stable operation. Furthermore, connection t o the l o c a l mains is simplified by a tapless switched-mode power supply t h a t covers most voltage ranges i n use:
14、 90 V . . . 264 V a.c. A l l these features make t h i s oscilloscope suitable for a wide range Of measuring applications. 2-2 2.2 CHARACTERISTICS A. Performance Characteristics - Properties expressed i n numerical values with stated tolerance are guaranteed by PHILIPS. Specified non-tolerance numer
15、ical values indicate those t h a t could be nominally expected from the mean of a range of i d e n t i c a l instruments. - This specification is valid a f t e r t h e instrument has warmed up f o r 30 minutes (reference temperature 2 3 O C ) . - For d e f i n i t i o n s of terms, reference i s mad
16、e t o IEC Publication 351-1. B. Safety Characteristics This apparatus has been designed and tested i n accordance with: Safety Class I requirements of I E C Publication 348 Safety Requirements for Electronic Measuring c _ i Apparatus, UL 1244 and CSA 556B. b The instrument has been supplied i n a sa
17、fe condition C. I n i t i a l Characteristics Height Without Feat and Accessory Pouch 170 mm ( 6 , 7 i n ) Feet and accessory pouch included 240 mm ( 9 , 4 i n ) Width 340 mm (13,4 i n ) Depth Handle Excluded 523 mm (20,6 i n ) With Extended handle 625 mm ( 2 4 , 6 ) Add 10 mm ( 0 , 4 i n ) f o r fe
18、et Add 46 mm (1,8 i n ) f o r handle Add 35 mm ( 1 , 4 i n ) f o r protective front cover. Mass 13,9 kg (30,7 l b ) - Operating positions: a ) Horizontally on bottom f e e t b ) Vertically on rear f e e t c) On t h e carrying handle i n three sloping positions= 1Z0, 20 and 25 D. CONTENTS 2.2.1. Disp
19、lay 2.2.2. Vertical channel or Y-axis 2.2.3. Channel A and B 2.2.4. Trigger view 2.2.5. Horizontal deflection or X-axis 86-02-07 2-3 2.2.6. 2.2.7. 2.2.8. 2.2.9. 2.2.10. 2.2.11. 2.2.12. 2.2.13. 2.2.14. 2.2.15. 2.2.16. 2.2.17. -Main time-base Delayed t ime-b a s e Main time-base t r i g g e r i n g De
20、layed time-base triggering Blanking o r Z-axis Auto s e t t i n g Cursors CRT text Calibrator Power supply Sundries Environmental c h a r a c t e r i s t i c s 2.2.18. Safety 2.2.19. Accesories CHARACTERISTIC SPECIFICATION 2.2.1. DISPLAY Cathode Ray Tube Measuring Area 80mm x loom (h. x w.) Screen t
21、ype: (basic version) GH (P31) ( 0 pt ional ) GM (P7) BE (P11) Total Acceleration Volt age : 24kV Max. Writing Speed (photographic) t y p i c a l 4cm/ns G r a t i c u l e - Illumination i n t e r n a l , fixed continuously variab 1 e ADDITIONAL INFORMATIION 140mm Rectangular single beam tube with h e
22、 l i c a l v e r t i c a l d e f l e c t i o n system. 8 divisions x 10 d i v i s i o n s Measured i n c e n t r a l 5 d i v x 5 d i v of screen; i n absence of contrast f i l t e r . Single Shot; Phosphor: GH; no prefogging; Lens aperture F:1,2; object t o image r a t i o 1:0,5; Film: Polaroid type
23、 612 (20 000 ASA). - Engravings : division l i n e s A t l c m Horizontal and vertical. t i c k marks dots percentages 0 r t hog ona 1 it y Trace Rot at ion: Min. Range 2.2.2. VERTICAL DEFLECTION OR Y-AXIS A t 2mm On vert. and hor. central axes and on hor. l i n e s at 2cm and 6cm from top. A t 2mm
24、On dotted l i n e s at 1,5cm and 6,5cm from top. 100, 90, 10, 0% To f a c i l i t a t e rise and f a l l time measurements. 90 + or -0,5 Measured at centre of screen. (Angle between X and Y axes, when traces are written i n X and Y direction alternately; deflection frequency: 50. .60Hz) 1 2 O Screwd
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PHILIPS. PM3295. Test. Service Manual. CDC-311. 电路图 PHILIPS PM3295 Test Manual CDC 311.
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-200467.html



Marshall-9100-62-02-Schematic电路原理图.pdf