1、M LCR131 Component tester User Manual MeterCenter (800) 230-6008 RadioFans.CN 收音机爱 好者资料库 LCR131 Parameters Measured L/C/R/D/Q Measuring Circuit Mode Inductance (L) Defaults to series mode Capacitance/ Resistance (C/R) -Defaults to parallel mode Displays L/C/R: Maximum display 19999 D/Q: Maximum disp
2、lay 999 (Auto Range). Ranging Mode Auto 0-70% R.H. Storage Temperature -20 to +50; 0-80% R.H. Low Battery Indication Approx. 6.8V Protective Fuse 0.1A/250V Fuse (input protective) Standard Accessories Test alligator clips (pair) DC 9V Battery. User manual Optional Accessories Carrying case RS232 pac
3、kage SMD Tweezers DC Adaptor (EA112: AC120V) / (EA55: AC220V). Dimensions (L/W/H) 184/ 87/ 41 mm Weight 330 grams RadioFans.CN 收音机爱 好者资料库 LCR131 COMPONENT TESTER USER MANUAL i RadioFans.CN 收音机爱 好者资料库 Table of Contents PAGE Safety 1 Introduction 3 Front Panel Illustration 4 LCD Display Illustration 5
4、 How to Operate 7 Operating Instructions 11 ? Data Hold 11 ? Static Recording 11 ? Dissipation Factor / Quality Factor 11 ? Test Frequency 12 ? L/C/R function selector 12 ? Relative 12 ? Tolerance 12 ? Auto/manual ranging 13 ? Automatic Fuse Detection 13 ? Parallel / Series Mode 13 ? Calibration 14
5、? Auto Power Off/ Disable Auto Power Off 15 ? Low Battery Indication 15 ? Communication 15 General Specification 17 Electrical Specification 18 Maintenance 21 ii Safety Read SAFETY INFORMATION before using this meter. ? NOTE This meter is a hand-held, battery-operated instrument for testing inductan
6、ce, capacitance and resistance. If this device is damaged or has any parts missing, contact the retailer immediately. This manual contains information and warnings which must be followed to ensure safe operation as well as to ensure the meter remains in a safe condition. Some common international el
7、ectrical symbols used in this manual are shown in the table below: DC - Direct Current See Explanation In The Manual Table 1-1. International Electrical Symbols Before using the meter, read the following safety information carefully. In this manual, WARNING, is reserved for conditions and actions th
8、at pose hazard(s) to the user; CAUTION, is reserved for conditions and actions that may damage your meter. 1 ? SAFETY INFORMATION To ensure that you use this device safely, follow the safety guidelines listed below: ? This meter is for indoor use, altitude up to 2,000 m. ? The warnings and precautio
9、ns should be read and well understood before the instrument is used. ? Use this device only as specified in this manual; otherwise, the protection provided by the meter may be impaired. ? When measuring in-circuit components, first de-energize the circuits before connecting to the test leads. ? Disc
10、harge capacitors before testing. ? The power for the meter is supplied with a single standard 9V battery. It is also possible to use external power using a 12V DC adaptor conforming to IEC 60950. 2 Introduction This 19,999-count L/C/R hand-held meter is a special microprocessor-controlled meter for
11、measuring functions of inductance, capacitance and resistance. Extremely simple to operate, the instrument not only takes absolute parallel mode measurements, but is also capable of series mode measurement. The meter provides direct and accurate measurements of inductors, capacitors and resistors wi
12、th different testing frequencies. It is possible to select between auto and manual ranging. Front panel pushbuttons maximize the convenience of function and feature selection such as data hold; maximum, minimum and average record mode; relative mode; tolerance sorting mode; frequency and L/C/R selec
13、tion. The test data can be transferred to PC through an optional full isolated optical RS232C interface and CP-09 software. A tilt stand provides position flexibility for viewing and operating the meter. The rubber over-molded case both protects the meter in harsh environments, and improves grip in
14、the hand. While single 9V battery operation is standard for the meter, a standard DC 12V power adaptor can also be used as an optional power input. 3 Front Panel Illustration 1. LCD display 2. Power ON/OFF button 3. RS232 selector 4. Dissipation factor and Quality factor selection button 5. Test fre
15、quency selection button 6. Inductance, Capacitance and Resistance function selection button. Parallel and series mode selection button 7. Tolerance mode selection button 8. Data hold, Maximum, Minimum and Average reading selection button 9. Range selection button 10. Relative mode and Calibration se
16、lection button 11. DC 12V adaptor input 12. Input sockets and Terminals Figure-1. Front panel for LCR131. 4 LCD Display Illustration Figure 2. LCD Display. 1. AUTO: Auto-ranging indicator 2. LCR: L, C or R function indicator 3. MAX: Maximum reading indicator 4. AVG: Average reading indicator 5. REL:
17、 Relative mode indicator 6. MIN: Minimum reading indicator 7. DH: Data hold indicator 9. Q: Quality factor indicator 10. D: Dissipation factor indicator 11. : Secondary display 12. : Beeper tone indicator for tolerance mode 13. %: Tolerance (percentage) indicator 14. deg: Phase Angle degree indicato
18、r (Model-A only ) 15. kHz: Frequency indicator 16. MAX AVG MIN: Recording mode indicators 17. TOL: Tolerance mode indicator 18. 1%5%10%: Tolerance sorting (percent) indicator 19. : Auto power- off indicator 5 20. : Low battery indicator 21. PAL: Parallel mode indicator 22. SER: Series mode indicator
19、 23. Mk: Resistance (Ohm) indicator 24. : Inductance (Henry) indicator 25. : Capacitance (Farad) indicator 26. : RS232 indicator Special Indication Characters : Indicates short connectors : Indicates open connectors : Indicates calibration mode : Indicates damaged or open fuse 6 How To Operate Cauti
20、on When measuring within a circuit, the circuit must be de-energized before connecting the test leads. Instruments used in dusty or dirty environment should be wiped and cleaned regularly. Do not expose instrument to direct sunlight or other heat sources for long periods. Ensure the instrument is di
21、sconnected from any circuit and powered OFF before removing battery cover. Note: For achieving optimum precision for all L, C and R measurements throughout all ranges, the instrument should be internally calibrated before each use. 7 ? Inductance Measurement 1. Press the POWER button to turn on the
22、meter. 2. Press “L/C/R” button to select inductance measurement. 3. Insert an inductor into component receptacle socket or connect the test clip to the component leads as required. 4. Press “FREQ” button to select testing frequency. 5. Press “D/Q” button to select Q factor for secondary display. 6.
23、Read the display readings for inductance value and quality factor. Figure-3. Inductance Measurement. 8 ? Capacitance Measurement 1. Press POWER button to turn on the meter. 2. Press “L/C/R” button to select capacitance measurement. 3. Insert a capacitor into the component receptacle socket or connec
24、t the test clip to the component leads as required. 4. Press “FREQ” button to select testing frequency. 5. Press “D/Q” button to select D factor for secondary display. 6. Read the display readings for capacitance value and dissipation factor. Warning To avoid electrical hazards, discharge all capaci