1、100 MHz Dual-Channel Oscilloscope _ I-It7 F , , M , FLIAF)PE13, PM 32671 PM 3267U i:mm Service Manual 9499 445 021 11 84031 6/04 lPHlLlPSl Scientific often a problem with long signal wires. In the TRIGGER INPUT STAGE, these current signals are converted into voltage form, and fed to the TRIGGER SELE
2、CTION CIRCUIT. The EXT trigger signal from the EXT input socket, and the LINE signal from the LINE TRIGGER PICK-OFF are fed to the TRIGGER SELECTION CIRCUIT via the EXT-LINE TRIGGER INPUT circuit. In this stage, the EXT and LINE trigger signals are converted to symmetrical current signals and adapte
3、d to the A, B and COMP signals. The EXT-LINE TRIGGER INPUT stage is controlled by the EXT pushbutton and LINE (pushbuttons B and EXT depressed simultaneously). In addition, the A and B trigger signals are fed to the TRIGGER SELECTION CIRCUIT of the DTB. 2. 1 . 2 . 1. - Main time-base The trigger sig
4、nals are selected by the MTB trigger source switches A, B, EXT, COMP, LINE, which control the TRIGGER SELECTION CIRCUIT. Common-mode interference is reduced by using a symmetrical configuration for the TRIGGER SELECTION This stage converts the symmetrical current signal to an asymmetrical voltage si
5、gnal, which is fed to the switches DC, LF, HF. Several signals are produced by the INTERFACE, e.g. X DEFL, TRIG VIEW and AUTO/TV. The X-DEFL signal is an asymmetrical signal that is fed to the X DEFLECTION AMPLIFIER. The symmetrical TRIG VIEW signal is routed to the VERTICAL CHANNEL SWITCH; the asym
6、metrical AUTO/TV signal is routed to the AUTO and TV CIRCUIT. The FINAL TRIGGER AMPLIFIER comprises the SLOPE circuit under the control of the SLOPE switch The output of the FINAL TRIGGER AMPLIFIER is fed to the CURRENT-VOLTAGE CONVERTER. In the AUTO CIRCUIT, the TOP DETECTOR detects the amplitude o
7、f the AUTO SIGNAL. When in the AUTO Mode, the LEVEL range is determined by this detected amplitude. The MULTIPLEXER is an electronic switch which, depending on the selected mode, selects the different ranges for the LEVEL control. Each mode has its own specific LEVEL range, for example: - CIRCUIT ou
8、tput signal. This output current signal is fed to the TRIGGER AMPLIFIER INPUT STAGE. INTERFACE via the TRIGGER COUPLING stage. The coupling is controlled by the MTB trigger coupling -_ L - incorporated in the LEVEL control. It permits positive and negative triggering. - .- TV : fixed level TRIG : f
9、8 divisions X DEFL : 0 divisions (LEVEL inoperative) AUTO : determined by TOP DETECTOR - If the instrument is provided with the TTL/ECL option, the TV pushbutton will function as the TTL or ECL mode switch. The TV trigger signal is fed to the TV CIRCUIT. When the TV pushbutton is selected, the TV CI
10、RCUIT is inserted between the INTERFACE and the CURRENT- VOLTAGE CONVERTER of the MTB. - - I In the TV mode, the FINAL TRIGGER AMPLIFIER is switched off and also the LEVEL control is inoperative, a fixed trigger level being set. For FRAME and LINE synchronisation, a frame or line filter is selected
11、with the MTB TIME/DIV switch. Via The SWEEP-GATING LOGIC determines the start of the MAIN TIME-BASE GENERATOR sweep. The SWEEP-GATING LOGIC is controlled by signals derived from the TRIGGER MODE SELECTION, the HOLD-OFF CIRCUIT and the CURRENT-VOLTAGE CONVERTER. The TRIGGER MODE SELECTION is controll
12、ed by the MTB trigger mode selection pushbuttons AUTO, TRIG, SINGLE. In the AUTO mode, the MAIN TIME-BASE GENERATOR runs automatically when no trigger pulses are available. In the TRIG mode, the MAIN TIME-BASE GENERATOR must be normally triggered by trigger signals derived fromthe CUR RENT-VOLTAGE C
13、ONVERTER. If the SINGLE pushbutton is selected, the SWEEP-GATING LOGIC will start the MAIN TIME-BASE GENERATOR for one sweep. - The MAIN GATE OUT signal (optional) is taken from the SWEEP-GATING LOGIC This MAIN GATE OUT signal output is at logic H during the MTB sweep and L for other conditions. The
14、 NOT TRIG LED lights up when the MTB is not triggered. the CURRENT-VOLTAGE CONVERTER, the trigger signal is routed to the SWEEP-GATING LOGIC. _ -_ - 2.1.2.2. 2-5 The MAIN TIME-BASE GENERATOR produces a sawtooth voltage, the repetition time being controlled by the TIME/DIV switch. To enable the capac
15、itors that determine the repetition rate sufficient time to discharge, the HOLD-OFF CIRCUIT is employed. This time is adjustable with the HOLD-OFF control. After the HOLD-OFF time, the HOLD-OFF CIRCUIT sends a signal to the SWEEP-GATING LOGIC, which in turn starts the next time-base sweep. The repet
16、ition rate of the MTB sawtooth voltage is continuously variable with the continuous control CAL. The output sawtooth voltage from the MTB is fed to the HORIZONTAL CHANNEL SWITCH circuit. Delayed time-base Channel A and B trigger signals are fed to the DTB TRIGGER SELECTION CIRCUIT via the TRIGGER IN
17、PUT STAG E . Trigger selection is controlled by the DTB trigger source selection pushbuttons A, B. The symmetrical output current signal from the TRIGGER SELECTION CIRCUIT is converted to an asymmetri- cal voltage signal in the TRIGGER AMPLIFIER INPUT STAGE. This signal is then fed via the TRIGGER C
18、OUPLING circuit to the FINAL TRIGGER AMPLIFIER. Trigger coupling is selected by thn DC, LF, HF pushbuttons. The FINAL TRIGGER AMPLIFIER comprises the LEVEL/SLOPE controls and their associated circuits. The asymmetrical input voltage signal is converted to an asymmetrical current signal, which is fed
19、 to the CURRENT- VOLTAGE CONVE RTE R . The output of the CURRENT-VOLTAGE CONVERTER and the output of the COMPARATOR are fed to the SW EEP-GAT I NG LOG IC. The COMPARATOR circuit compares the amplitude of the MTB sawtooth voltage with a d.c. voltage selected by the DELAY TIME control. If the amplitud
20、e of the MTB sawtooth is equal to the d.c. voltage, the COMPARATOR produces a signal that is then fed to the SWEEP-GATING LOGIC. If the MTB pushbutton of the delayed time-base trigger source switches is depressed, the SWEEP-GATING LOGIC starts the DELAYED TIME-BASE GENERATOR immediately after the DE
21、LAY TIME selected. If the A or B pushbutton is depressed, the SWEEP-GATING LOGIC detects the end of the delay time but waits for a trigger signal (A or B) from the CURRENT-VOLTAGE CONVERTER, after which the TIME-BASE GENERATOR starts. The DELAYED GATE OUT is taken from the SWEEP-GATING LOGIC when th
22、is option is available. The output is at logic H during the DTB sweep and L for other conditions. The DTB sawtooth voltage is produced in the DELAYED TIME-BASE GENERATOR under the control of the TIME/DIV switch and its continuous CAL control. If the UNCAL LED lights up, it indicates that the continu
23、ous controls of one or both time-bases are not in the CAL position. 2.1.2.3. Horizontal channel selection and final horizontal amplifier In the X DELFECTION AMPLIFIER the X DEFL signal derived from the MTB INTERFACE is amplified and fed to the HORIZONTAL CHANNEL SWITCH circuit. The HORIZONTAL CHANNE
24、L SWITCH selects the X DEFL, MTB and/or DTB signals under the control of the HORIZONTAL CHANNEL SELECTION LOGIC, which in turn is controlled by the horizontal display mode switches X DEFL, DTB, ALT TB, MTB. If the X DEFL pushbutton is selected, the signal chosen by the MTB trigger source selection s
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PHILIPS. PM3267. Test. Service Manual. CDC-311. 电路图 PHILIPS PM3267 Test Manual CDC 311.
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-200470.html



Marshall-9100-62-02-Schematic电路原理图.pdf