1、MM PAT4E Appliance Tester User Guide MEGGER RadioFans.CN 收音机爱 好者资料库 Contents 2 Safety Warnings 3 General Description 4 Features and Controls 5 Quick-start Guide 6 Settings 12 Contrast Adjustment 12 Reset to default Settings 12 Short cut to Comms Upload (from PC) 12 Language of operation 12 Test resu
2、lts printout 12 Function Setting adjustment 13 User name and Pin number 13 Setup Manual/Autopass testing 14 Setup Buzzer 14 Setup Test Times 15 Setup Clock 17 Setup Test Company Title 18 Client and Locations 19 Select an existing Client and Location 19 Select a new Client and Location 19 Edit Client
3、/Location details 21 Erase Client details 21 Erase Location details 22 Add new Client, main address, site location 22 Add new site Location details 23 Asset Test Groups 25 Table of test group combinations 26 Add new Group 27 Edit a Group 27 Erase a Group 28 Assets 31 Add Asset 31 Edit Asset 33 Erase
4、 Asset 33 Locate an Asset 35 Testing Asset 37 Automated Testing 37 Quick-Check 39 Repair codes 40 Erase Memory 41 Communications 42 Print Report 42 Download / Upload data 44 Serial lead connections 44 Download to a computer 44 Upload from a computer 44 Description of tests 45 Visual Inspection Test
5、45 RISO Insulation Test 45 RPE Earth Continuity Test 45 Operation Test 46 IDIFF Differential Earth Leakage Test 46 IPE Substitute Discharge Leakage Test 46 IF Absence of Potential Leakage Test 46 Fuse Test 46 Extension Lead Testing 46 Three Phase Testing Typical Configurations 47 Demonstration Data
6、48 Specifications 52 Accessories 54 Repair and Warranty 55 Symbols used on the instrument. Caution: Refer to accompanying notes Risk of electric shock. Equipment complies with relevant EU Directives RadioFans.CN 收音机爱 好者资料库 Safety. 3 SAFETY WARNINGS Safety Warnings and Precautions must be read and un
7、derstood before the instrument is used. They must be observed during use. For safety, PAT4E must be properly earthed. Only use a supply socket that has a protective earth contact. Test leads, probes and crocodile clips must be in good order, clean and with no broken or cracked insulation. For safety
8、, tests are performed in the correct order. If an asset (appliance) fails a test, PAT4E will fail the asset and exit the test sequence. The fault causing the failure must be corrected before the appliance is re-tested. During testing, ensure that no hazard will exist if the asset operates as a resul
9、t of normal running, or of a fault condition. When performing an Insulation test the asset must not be touched. Only perform an Operation test after an RPE Test (Class 1 only) and Insulation RISO Test (Class 1 or Class 2) have been verified. The instrument should not be used if any part of it is dam
10、aged. Replacement fuses must be of the correct type and rating. See Specification section. NOTE: THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSON RadioFans.CN 收音机爱 好者资料库 General Description. 4 The PAT4E Portable Appliance Testers provide significant advances in the ease of u
11、se, with comprehensive features designed to speed up the testing of electrical equipment. The instruments meets the testing requirements of the UK Electricity at Work Regulations, IEE Code of Practice for In Service Inspection and Testing of Electrical Equipment, VDE 0701 and NEN 3140 specifications
12、. The instruments may be used stand alone, or for maximum advantage, with PC based software, such as Form Filler T M for Windows T M (See Accessories). The integral real time clock “stamps” an accurate time and date on every test. PAT4E utilise a unique concept known as Test Groups. This permits ver
13、y rapid addition and testing of equipment with a minimum of data entry. Once set up, the use of Test Groups will save a great deal of time. Additionally, Test Groups ensure that only the correct tests can be applied to the equipment under test and eliminate the need for complex test codes. PAT4E pro
14、vides a professional system for the rapid testing of equipment while maintaining the essential traceability of asset test history. The on-board Asset (Appliance) database keeps a record of appliance details, re-test frequency, test and re-test dates, and allows the previous test results to be displa
15、yed at the time of test. As well as the easy to use QWERTY keyboard, each field is named, so there is less chance of entering the wrong information. Data entry via optional bar code scanners is also possible. The lithium backed real time clock maintains the time and date accurately for over ten year
16、s and automatically date and time stamps every asset tested. Data is stored in battery backed, solid state memory that under normal circumstances will be protected for ten years. Such storage media is however susceptible to external influences such as transients and static discharge. These effects m
17、ay cause data corruption or loss. Megger Limited cannot accept responsibility for any such losses of data. When the PAT4E is used with PC software such as Form Filler T M, employing good working practices, such as the regular downloading of data will substantially reduce the risk. The following info
18、rmation can be stored and accessed directly on the PAT4E. Assets (Appliances) - total number 1000 Results (sets of) 1000 Clients (names and addresses) 10 Locations (Site details) 20 Test Groups 50 Users 10 The instruments can perform the following tests: Visual Inspection list Fuse Test Circuit test
19、 (pre-test) Earth Continuity test (RPE) Insulation test (RISO) Operation Test. Extension Lead testing. Differential Earth Leakage Test. (IDIFF) Touch Current Test (IF) Equivalent Earth Leakage Test (IPE) Features and Controls. 5 Mains power Connection 12.5 A Protection Fuses 3 Phase Test Connections
20、 Appliance Test Connections Fuse Test Points Lead and Accessory Storage Bar Code Scanner and PC Connection Parallel Printer Connection ESC / DEL key And Multi function Soft key OK key And Multi - function Soft key Space = Shift + 0 Extension Lead Test Connection RPE Test Terminal IF Test Terminal Mu
21、lti - function Soft keys Display FUSES - Due to the often harsh electrical environments in which Portable Appliance Testers are used and the likelihood of testing faulty equipment all Megger Portable Appliance Testers are protected by appropriate internal fuses. This ensures that the instrument is p
22、rotected from serious damage. An unfortunate downside to using internal protection fuses is that the PAT4 can be rendered inoperative simply by the failure of such a fuse resulting in frustration and delay for the user. In order to ensure that the instrument can quickly be put back into service with
23、out downgrading its protection externally located fuses are now fitted to all new PAT4 models. These may be changed quickly and simply by the user in the event of a failure. For maximum convenience all fuses are of the same value. Additionally the PAT4 display will now indicate which fuse has failed
24、, unless of course it is main supply fuse in which case the screen will be blank. Replacement of Fuses Always disconnect the PAT4 from the main supply before checking fuses. Use correct replacement fuses as printed adjacent to the fuse - Megger Part No. for replacement fuses 25950-014 FS2 FS1 Quick
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Biddle PAT4E_UG 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf