1、 5700A/5720A Series II Multi-Function Calibrator Getting Started PN 1668111 March 2002 2002 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. RadioFans.CN 收音机爱 好者资料库 LIMITED WARRANTY the display shows linearity, offset, and scale e
2、rrors Keys that multiply and divide the output value by 10 to simplify work on meters with calibration points at decade multiples of a fraction of full-scale Programmable entry limits used for restricting the levels that can be keyed into the calibrator, preventing access to levels that may be harmf
3、ul to equipment or personnel A s key that provides the capability of displaying the instruments specification at the selected operating point, calibration interval, and specification confidence level 5700A/5720A Series II Getting Started 2 An auxiliary current binding post that allows you to calibra
4、te meters with separate current inputs without moving cables Real-time clock and calendar for date stamping reports Offset and scaling modes that simplify linearity testing of multimeters Variable phase reference signal output and phase-lock input Interface for the Fluke 5725A Amplifier Standard IEE
5、E-488 (GPIB) interface, complying with ANSI/IEEE Standards 488.1-1987 and 488.2-1987 Selectable normal remote mode or emulation of the Fluke 5100B and 5200A Series calibrators in functions and response to system controller software EIA Standard RS-232C serial data interface for printing, displaying,
6、 or transferring internally-stored calibration constants, and for remote control of the calibrator Extensive internal self-testing and diagnostics of analog and digital functions A traceable calibration procedure for all modes and ranges that requires only 10 V, 1 , and 10 k external standards, with
7、 only occasional independent verification Fast, simple, automated calibration check providing added confidence between calibration recalls, and data that can be used to document and characterize the calibrators performance between calibration recalls Instruction Manuals The 5700A/5720A Series II Cal
8、ibrators ship with a complete manual set that contains information for the operator and service or maintenance technicians. The set includes: 5700A/5720A Series II Getting Started Manual (PN 1668111) 5700A/5720A Series II Operator Reference Guide (PN 601648) 5700A/5720A Series II Remote Programming
9、Reference Guide (PN 601655) 5700A/5720A Series II Operator Manual (provided on CD-ROM, PN 1668127, or a printed copy is available for purchase through the Fluke Service Department under PN 601622) 5700A/5720A Series II Service Manual (provided on CD-ROM, PN 1668127, or a printed copy is available fo
10、r purchase through the Fluke Service Department under PN 105798) Order additional copies of these instruction manuals separately using the part numbers provided. For ordering instructions, refer to the Fluke Catalog or contact a Fluke sales representative. Getting Started Wideband AC Voltage Module
11、(Option 5700A-03) 3 Wideband AC Voltage Module (Option 5700A-03) The Wideband AC Voltage Module (Option 5700A-03) can be installed in both the 5700A and 5720A Series II Calibrators. The module is a high-accuracy, low-noise, extremely flat ac voltage source for calibrating rf voltmeters, with a frequ
12、ency range of 10 Hz to 30 MHz. Output is in seven ranges from 300 V (-57 dBm) to 3.5 V (+24 dBm) through a Type-N coaxial connector into a 50 load. The output level is selected in volts or dBm through either the front panel controls or under remote control. The wideband module also functions with th
13、e calibrators output adjust controls that let display the error of a wideband meter in either percentage of output or in decibels. Included with the wideband module is a Type-N output cable and a 50 terminator. The wideband module is calibrated to the end of its standard-equipment output cable. Auxi
14、liary Amplifier The Fluke Model 5725A Amplifier is available to extend the high voltage performance and current range of the calibrator: Interface connectors on the calibrators rear panel accept cables to directly operate a 5725A. Three amplifiers can be connected to the calibrator at the same time,
15、 but only one output can be active at a time. Once you have connected the amplifiers and configured the calibrator in a setup menu, amplifier operation is controlled by the calibrator. Operating instructions for the 5725A are provided in Chapter 4 of the Operators Manual. The General Specifications
16、include specifications for operating the calibrator with the 5725A. For other amplifier specifications, refer to their instruction manuals. Table summarizes the extended capabilities offered by the 5725A. Brief descriptions of the extended capabilities follow. Table 1. Auxiliary Amplifier Data Model
17、ModeRange 5725A AmplifierAC V20 to 1100 V rms up to 70 mA, 40 Hz to 30 kHz (50 mA 1 V/m but 3 V/m, add 0.01% of range. Relative Uncertainty 1 C 24 Hours90 Days180 Days1 Year24 Hours90 Days (ppm output + V) (ppm output + V) 220 mV10 nV0 5 + 0.57 + 0.50 8 + 0.50 9 + 0.50 2 + 0.42.5 + 0.4 2.2 V100 nV3.
18、5 + 0.84 + 0.84.5 + 0.80 6 + 0.80 2 + 0.82.5 + 0.8 11 V1 V2.5 + 33 + 33.5 + 30 4 + 30 1 + 31.5 + 3 22 V1 V2.5 + 53 + 53.5 + 50 4 + 50 1 + 51.5 + 5 220 V10 V3.5 + 504 + 500 5 + 506 + 502 + 502.5 + 50 1100 V100 V0 5 + 5006 + 5000 7 + 5008 + 5002.5 + 4003 + 400 5720A 95% 95% Confidence Level RangeResol
19、ution Absolute Uncertainty 5 C from calibration temperature For fields strengths 1 V/m but 3 V/m, add 0.01 % of range. Relative Uncertainty 1 C 24 Hours90 Days180 Days1 Year24 Hours90 Days (ppm output + V) (ppm output + V) 220 mV10 nV4 + 0.40 6 + 0.46.5 + 0.47.5 + 0.41.6 + 0.402 + 0.4 2.2 V100 nV3 +
20、 0.73.5 + 0.70 4 + 0.705 + 0.71.6 + 0.702 + 0.7 11 V1 V2 + 2.52.5 + 2.503 + 2.53.5 + 2.50.8 + 2.51.2 + 2.5 22 V1 V2 + 42.5 + 403 + 43.5 + 40.8 + 41.2 + 4 220 V10 V3 + 403.5 + 4004 + 400 5 + 401.6 + 4002 + 40 1100 V100 V4 + 4004.5 + 40006 + 4006.5 + 40002 + 4002.4 + 400 5700A/5720A Series II Getting
21、Started 12 Table 3. 5700A Series II DC Voltage Specifications: 99 % and 95 % Confidence Levels 5700A 99% 99 % Confidence Level RangeResolution Absolute Uncertainty 5 C from calibration temperature For fields strengths 1 V/m but 3 V/m, add 0.01 % of range. Relative Uncertainty 1 C 24 Hours90 Days180
22、Days1 Year24 Hours90 Days (ppm output + V) (ppm output + V) 220 mV10 nV6.5 + .757 + .7508 + .7509 + .82.5 + .54 + .5 2.2 V100 nV3.5 + 1.26 + 1.207 + 1.208 + 1.22.5 + 1.24 + 1.2 11 V1 V3.5 + 35 + 407 + 408 + 41.5 + 33.5 + 4 22 V1 V3.5 + 65 + 807 + 808 + 81.5 + 63.5 + 8 220 V10 V5 + 1006 + 10008 + 100
23、09 + 1002.5 + 1004 + 100 1100 V100 V7 + 6008 + 60010 + 60011 + 6003 + 6004.5 + 600 5700A 95% 95 % Confidence Level RangeResolution Absolute Uncertainty 5 C from calibration temperature For fields strengths 1 V/m but 3 V/m, add 0.01 % of range. Relative Uncertainty 1 C 24 Hours90 Days180 Days1 Year24
24、 Hours90 Days (ppm output + V) (ppm output + V) 220 mV10 nV5.5 + 0.66 + 0.67 + 0.68 + 0.62 + 0.43.5 + 0.4 2.2 V100 nV3.5 + 15 + 16 + 17 + 12 + 13.5 + 1 11 V1 mV3 + 3.54 + 3.56 + 3.57 + 3.51.2 + 33 + 3.5 22 V1 mV3 + 6.54 + 6.56 + 6.57 + 6.51.2 + 63 + 7 220 V10 mV4 + 805 + 807 + 808 + 802 + 803.5 + 80