1、English73 Series III Instruction Sheet. Panel 1 73 Series III Multimeter Instruction Sheet Read First: Safety Information W To avoid damage to the meter, electric shock or injury: Never use the meter if the meter or test leads look damaged. Be sure the test leads and rotary switch are in the correct
2、 position for the desired measurement. Never measure resistance in a circuit when power is applied. Never touch the probes to a voltage source when the test leads are plugged into the 10 A or 300 mA input jack. Never use the meter on circuits that exceed 4800 volt-amps. Never apply more than the rat
3、ed voltage between any input jack and earth ground. Be careful when working with voltages above 60 V dc or 30 V ac rms. Such voltages pose a shock hazard. Keep your fingers behind the finger guards on the test probes when making measurements. W Warning To avoid false readings, which could lead to po
4、ssible electric shock or personal injury, replace the battery as soon as the low battery indicator (M) appears. Symbols W Caution: Important Information. See instruction sheet. MAN Manual Range. T Double Insulation. M Low battery. Replace battery. CAT II Overvoltage Installation Category per IEC 610
5、10-1-95. CAT II instruments protect against transients from equipment supplied from the fixed installation, e.g., TV, PC, and household appliances. PN 1646063 February 2002 (English) 1997, 1998, 2002 Fluke Corporation. All rights reserved. Printed in China. RadioFans.CN 收音机爱 好者资料库 English73 Series I
6、II Instruction Sheet. Panel 2 Terminals 300 mA 10A FUSED 600V CAT V COM Milliamps Amps Volts, Ohms, Diode Test Common Terminal hr2f.eps See Specifications for overload protection. Pushbutton Use the pushbutton to either select a fixed range or put the meter in the Automatic Touch Hold mode. Autorang
7、e The meter defaults to autorange when first turned on. Manual Range Manual ranging is available in V ac, V dc, ohms, A ac, and A dc. The manual range mode and Touch Hold mode are mutually exclusive. MAN is displayed when the meter is in the manual range mode. Momentary + _ V MAN hr14f.eps To return
8、 to autorange, press R for 1 second or change the measurement function. RadioFans.CN 收音机爱 好者资料库 English73 Series III Instruction Sheet. Panel 3 Automatic Touch Hold Mode W Warning To avoid electric shock, do not use the Touch Hold mode to determine if a circuit with high voltage is dead. The Touch H
9、old mode will not capture unstable or noisy readings. The Touch Hold mode automatically captures and displays stable readings. Press R for 2 seconds. HOLD is displayed when the meter is in the Touch Hold mode. 2 seconds + _ V DC V DC _ + _ single beep VVV HOLDHOLD V DC HOLD hr3f.eps When the meter c
10、aptures a new input, it beeps and a new reading is displayed. Note Stray voltages can produce a new reading. To exit the Touch Hold mode, press R or change the measurement function. The Touch Hold mode and manual range mode are mutually exclusive. Bar Graph The bar graph shows readings relative to t
11、he full scale value of a displayed measurement range and indicates polarity. hr16f.eps RadioFans.CN 收音机爱 好者资料库 English73 Series III Instruction Sheet. Panel 4 Standby If the meter is on but is inactive for an hour (20 minutes in diode test), the screen goes blank and displays selected bar graph segm
12、ents. To resume operation, turn the rotary switch or press R. AC and DC Voltage (K L mL) + _ + _ V AC V DC + _ Volts ACVolts DCMillivolts DC V V V mV hr4f.eps Resistance (e) Turn off the power and discharge all capacitors. An external voltage across a component will give invalid resistance readings.
13、 + _ k hr6f.eps English73 Series III Instruction Sheet. Panel 5 Diode Test (G) Forward Bias Single Beep Reverse Bias Shorted Open or Good Diode Bad Diode + _ + _ Bad Diode + _ Good Diode + _ hr7f.eps English73 Series III Instruction Sheet. Panel 6 Continuity Test ( R ) + _ + _ hr5f.eps If continuity
14、 exists (resistance 210 ), the beeper sounds continuously. The meter beeps twice if it is in the Touch Hold mode. Current (? A) W Warning To avoid injury, do not attempt a current measurement if the open circuit voltage is above the rated voltage of the meter. To avoid blowing an input fuse, use the
15、 10 A jack until you are sure that the current is less than 300 mA. Turn off power to the circuit. Break the circuit. (For circuits of more than 10 amps, use a current clamp.) Put the meter in series with the circuit as shown and turn power on. DC + _ 1 4 3 2 VA hr8f.eps English73 Series III Instruc