1、BOONTON ELECTRONICS a Wireless Telecom Group Company 4400A/4500A MANUAL ADDENDUM Applies to Instruction Manual Model 4500A RF Peak Power Meter /Analyzer, Model 4400A RF Peak Power Meter, Part Number 98404700A, revised 09/97. Effective for Control Software Revision 20020511 and later. 1.0 NEW FEATURE
2、S 1.1 Peak Sensor Temperature Compensation When used with a peak sensor that contains a valid temperature compensation table, the model 4400A and 4500A Peak Power Meters can provide temperature compensated power measurements. The default mode for temperature compensation is active. The Chan n Calibr
3、ationTemp Comp menu box will be visible with “Sensor Tbl” displayed. To turn off temperature compensation press the menu button and “Off” will be displayed. The “Off” setting is volatile and not preserved through power cycles or major mode changes. If the sensor in use does not have a temperature co
4、mpensation table the Temp Comp menu box will not appear at all. The SpclChan n Sensor report will include the message “Sensor has Temperature Compensation Table” when appropriate. The SpclServicingConfiguration report shows TC system status if either channel has a sensor with a valid table. The form
5、at of this message if present is: TC System Status 1:err code # 2:err code # The error codes are: 0 No error. 145 TC # of Temps Err Table parameter error 146 TC # of Powers Err Table parameter error 147 TC Interp Err Table interpolation error 148 TC Expand Err Table expansion error 149 TC Extend Err
6、 Table extension error 150 TC Chksum Err Table read checksum error 151 TC Table Length Error 152 TC Temp Value Err A temperature value is out of range 98404706A 1 RadioFans.CN 收音机爱 好者资料库 153 TC Temp Non-mono A temperature array is non-monotonic 154 TC Power Value Err A power value is out of range 15
7、5 TC Power Non-mono A power array is non-monotonic 156 TC Corr Value Err A correction value is out of range Use CH1 or CH2 to specify to which channel the following temperature compensation related GPIB commands apply: TCON Turn on temperature compensation if available. If not, ignore. TCOFF Turn of
8、f temperature compensation. This is a volatile setting if compensation is available. 1.2 Sensor Auto-calibration File Retention Sensor auto-calibration files are now saved by channel as .AC1 and .AC2 files in non- volatile (flash) memory. This avoids the need to perform auto-cal every time a sensor
9、is removed and replaced by a different one, provided the sensors are known to the channel(s) involved. When a sensor is plugged-in a search is made to find an existing auto-cal file. If one is found, it is installed. If not, the “Needs Auto-cal” message will appear. When auto-cal is performed the ex
10、isting file is overwritten with the new result. If no previous file exists, one is created. Sensor filenames have the form SEN#.AC n, where # is the serial number and n is the channel number. The file directory system is expanded to display auto-calibration files in flash memory as well as the previ
11、ous files on the floppy disk. The UtilityDiskFlash Disk path lists sensor auto-cal files by channel. The Select File menu contains a sequence number which refers to the position of the file in the list. The selected file is shown in RED and may be deleted by pressing the menu button next to the “Del
12、ete” box. Deletion of files must be confirmed or cancelled. There are no GPIB operations on the file directory. 1.3 Color *.bmp File of Display The Hardcopy section now includes a color *.bmp file of the current display that can be saved to the floppy disk, sent to the COM1 port or the GPIB. To sele
13、ct this feature set the UtilHardcopyDevice menu to “Plotter”. Then select UtilHardcopyModel “.BMP”. Choose the Plot Label, Output Port and File Select number if the output is the floppy disk. Graph & Text is not applicable. Note that the “IEEE-488” output selection applies to the listen only (lon) G
14、PIB addressing mode only. For controller directed GPIB output 98404706A 2 RadioFans.CN 收音机爱 好者资料库 see below. Press the PLOT key to send the file to the selected output. The .bmp extension is added to the floppy disk file directory to allow viewing the filenames saved on disk. The GPIB commands for c
15、ontroller directed return of the .bmp file contents are: Send the sequence PLOTTER PLOT.BMP to select the bit-map mode. Send TKPLOT to set the talk mode that returns the file when addressed to talk. The GPIB commands to send the plot file contents to an output other than the GPIB are: Send the seque