FLUKE 730A 电路图.pdf
《FLUKE 730A 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE 730A 电路图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、 PIN: 009083-003 TB 9-4931-702-50 CHANGE 3 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR DC TRANSFER STANDARD JOHN FLUKE MODELS 730A AND 730A/AB Headquarters, Department of the Army, Washington, DC 20 August 2001 Approved for public release; distribution is unlimited. TB 9-4931
2、-702-50, 10 May 1974, is changed as follows: 1. Remove old pages and insert new pages as indicated below. New or changed material is indicated by a vertical bar in the margin of the page. Remove pages Insert pages 1 and 2 1 and 2 5 and 6 5 and 6 2. File this change sheet in front of the publication
3、for reference purposes. Distribution: To be distributed in accordance with Std. IDS No. RLC-1500, 11 May, 1992. . 0120707 RadioFans.CN 收音机爱 好者资料库 PIN: 009083-002 TB 9-4931-702-50 Change 2 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR DC TRANSFER STANDARD, JOHN FLUKE MODELS 730A
4、 AND 730A/AB Headquarters, Department of the Army, Washington, DC 18 February 1986 TB 9-4931-702-50, 10 May 1974, is changed as follows: Page 2. In table 2, item A2, Minimum Use Specifications column, add superscript 1. In table 2, add footnote to table as follows: “1Prior to using the NULL DETECTOR
5、, determine sensitivity on the 3 and 10 V ranges, using A1 and A4.” By Order of the Secretary of the Army: JOHN A. WICKHAM, JR. General, United States Army Chief of Staff Official: MILDRED E. HEDBERG Brigadier General, United States Army The Adjutant General Distribution: To be distributed in accord
6、ance with Std. IDA No. RLC-1500, 17 June 1985. US GOVERNMENT PRINTING OFFICE: 1987 - - 733-293/40535 REGION #4 RadioFans.CN 收音机爱 好者资料库 PIN: 009083-001 TB 9-4931-702-50 Change 1 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR DC TRANSFER STANDARD, JOHN FLUKE MODELS 730A AND 730A/A
7、B Headquarters, Department of the Army, Washington, DC 20 September 1984 TB 9-4931-702-50, 10 May 1974, is changed as follows: Page 3. Figure 1 is superseded as follows: Figure 1. Absolute voltage - equipment setup. RadioFans.CN 收音机爱 好者资料库 Page 4. Figure 2 is superseded as follows: Figure 2. Output
8、voltage - equipment setup. Page 4, paragraph 9b. Add the note below, following the second note. NOTE Do not report the adjustments in this paragraph unless the applicable measurement in the performance check exceeds 10 microvolts. Page 6, paragraph 10b. Add the note below, following the second note:
9、 NOTE Do not report the adjustments in this paragraph unless the applicable measurement in the performance check exceeds 10 microvolts. By Order of the Secretary of the Army: FRED C. WEYAND General, United States Army Chief of Staff Official: VERNE L. BOWERS Major General, United States Army The Adj
10、utant General Distribution: To be distributed in accordance with Std. IDA No. RLC-1500, 17 June 1985. U. S. GPO 1975-0 - 564 - 493/1438 CHANGE 3 TB 9-4931-702-50 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR DC TRANSFER STANDARD, JOHN FLUKE MODELS 730A AND 730A/AB Headquarters,
11、 Department of the Army, Washington, DC 10 May 1974 REPORTING OF ERRORS AND RECOMMENDED CHANGES You can help improve this publication. If you find any mistakes or if you know of a way to improve the procedure, please let us know. Mail your letter or DA Form 2028 to: Commander, U. S. Army Aviation an
12、d Missile Command, ATTN: AMSAM-MMC- MA-NP, Redstone Arsenal, AL 35898-5230. A reply will be furnished to you. You may also send in your comments electronically to our e-mail address: 2028redstone.army.mil, or FAX 256-842-6546/DSN 788-6546 Paragraph Page SECTION I. IDENTIFICATION AND DESCRIPTION Test
13、 instrument identification.1 2 Forms, records, and reports.2 2 Calibration description.3 2 II. EQUIPMENT REQUIREMENTS Equipment required.4 3 Accessories required.5 3 III. CALIBRATION PROCESS Preliminary instructions.6 3 Loop closure .7 4 Linearity of output resistance divider and Output voltage chec
14、k (Model 730A).8 5 Linearity of output resistance divider and Output voltage check (Model 730A/AB).9 9 Final procedure.10 12 TB 9-4931-702-50 2 CHANGE 3 SECTION I IDENTIFICATION AND DESCRIPTION 1. Test Instrument Identification. This bulletin provides instructions for the calibration of Dc Transfer
15、Standard, John Fluke Models 730A and 730A/AB. The manufacturers instruction manuals were used as the prime data source in compiling these instructions. The dc transfer standard will be referred to as the TI (test instrument) throughout this bulletin. a. Model Variations. Variations among models are
16、described in text. b. Time and Technique. The time required for this calibration is approximately 4 hours, using the dc and low frequency technique. 2. Calibration Data Card, DA Form 2416 a. Forms, records, and reports required for calibration personnel at all levels are prescribed by TM 38-750. DA
17、Form 2416 must be annotated in accordance with TM 38- 750 for each calibration performed. b. Adjustments to be reported on DA Form 2416 are designated (R) at the end of the sentence in which they appear. When adjustments are in tables, the (R) will follow the designated adjustment. Report only those
18、 adjustments made and designated with (R) 3. Calibration Description. TI parameters and performance specifications which pertain to this calibration are listed in table 1. NOTE For calibration of model 730A to be valid, the TI E control must be set to the last 3 digits of the value of standard cell
19、used in the calibration. Table 1. Calibration description Test Instrument Parameters Performance Specifications Accuracy (ARITH MEAN Of 1.018 E Output).1 With 10 v of calibrated value at end of calibration period. Transfer Voltage Accuracy2 10 V: 10 V 1.00 V: 1 V (1.018 E): 1 V (1.019 + E): 1 V E: 0
20、.0 To 999 V In 1 V Steps: 1V 1This value is not the manufacturers specified value. This value is the maximum drift allowed over a 90-day period as determined for Army calibration applications. 2Accuracy to which voltage can be standardized. TB 9-4931-702-50 3 SECTION II EQUIPMENT REQUIREMENTS 4. Equ
21、ipment Required. Table 2 identifies the specific equipment used in this calibration procedure. This equipment is issued with secondary reference calibration standards set 4931-621-7878 and is to be used in performing this procedure. Alternate items may be used by the calibrating activity when the eq
22、uipment listed in table 2 is not available. The items selected must be verified to perform satisfactorily prior to use and must bear evidence of current calibration. The equipment must meet or exceed the minimum use specifications listed in table 2. The accuracies listed in table 2 provide a four-to
23、-one accuracy ratio between the standard and TI. Where the four-to-one ratio cannot be met, the actual accuracy of the equipment selected is shown in parenthesis. 5. Accessories Required. The accessories listed in table 3 are issued .with secondary reference calibration standards set 4931-621-7878 a
24、re to be used in this calibration procedure. When necessary, these items may be substituted by equivalent items unless specifically prohibited. Table 2. Minimum Specifications of Equipment Required Item Common Name Minimum Use Specifications Manufacturer, Model And Part Number A1 DC VOLTAGE STANDARD
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FLUKE 730A 电路图 730
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


