eaton_2075_HP_8970a_part_2 电路图.pdf
《eaton_2075_HP_8970a_part_2 电路图.pdf》由会员分享,可在线阅读,更多相关《eaton_2075_HP_8970a_part_2 电路图.pdf(38页珍藏版)》请在收音机爱好者资料库上搜索。
1、F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 1 Noise & gain measures from 2 to 18 GHz with Eaton 2075 & HP 8971b and adds RadioFans.CN 收音机爱 好者资料库 F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 2 Radio
2、Fans.CN 收音机爱 好者资料库 F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 3 Overview PART 2 MEASUREMENTS WITH EXTERNAL MIXER - This 2nd Powerpoint is illustrating hits and kinks about gain and NF measurements OVER 2 GHz with both Eaton 2075a and HP or Agilent
3、 8970a analysers. - Solutions are covering the 2 18 and up to 26 GHz band RadioFans.CN 收音机爱 好者资料库 F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 4 1- The solutions in the industrial world: - HP-8971b or c NF extension test-set - Eaton NGA frequency ex
4、tender 4- Calibration of unknown noise sources from 2 to 18 GHz 3- X, Y and Z outputs to an oscilloscope Abstract 2- Direct low-cost DSB measurements using a single broadband mixer 5- Conclusions F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 5 1- The
5、 solutions in the industrial world F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 6 The choice in the industrial world - Model b goes up to 18 GHz and c, up to 26 GHz - 2 HPIB cables needed between analyser, extention and sweep Agilent HP 8971b (or c
6、model) noise figure test-set RF inputIF outputLO input Measuring mode indicators (DSB, USB, LSB, direct Operation Modes: - Band 1 - SSB1 (10-1600 MHz) using HP 8970b internal mode - Band 2 - SSB2 (1601-2400 MHz, 700 MHz IF) - Band 3 - SSB3 (2401-18000 MHz, 450 MHz IF) - Band 4 - DSB (2401-18000 MHZ,
7、 10 MHz IF) Its principally constitued by: - a YIG following filter with HPIB tracking software - an RF front-end broadband preamp - a broadband mixer F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 7 The choice in the industrial world Agilent HP 8971b
8、 (or c model) noise figure test-set HP 8971b or c HP 8970b Sweep or syntheziser F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 8 Agilent HP 8971b (or c model) noise figure test-set The choice in the industrial world 2 to 18 GHz LO like HP 8350b - Not
9、supported by the HP 8970a model ! - In the figure, replace preamp + mixer by the NF test-set (+ additional Yig tracking filter) HPIB cable Configuration mode 1.1 choice = DSB mode with variable RF, external variable LO, fixed LO F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2
10、075 or HP 8970b and ADDS 9 The choice in the industrial world Agilent HP 8971b (or c model) noise figure test-set DSB or SSB mode F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 10 Agilent HP 8971b (or c model) noise figure test-set The choice in the i
11、ndustrial world - With relatively broadband amps, the DSB mode is preferred - In this case the error between DSB and SSB mode is little, because IF signal of equal strengths - No need of additional filter or preamplifier F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or H
12、P 8970b and ADDS 11 The choice in the industry Eaton (Maury) MT 7550 series noise gain analyser frequency extender, up to 29 GHz The choice of only DSB mode measurements possibility gives a design with : - no internal tracking filter - no HPIB tracking requirement, only between analyser and sweep ge
13、nerator - no need of additional filter, only a broadband preamplifier - far cheeper to build and align HPIB cable F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 12 The choice in the industry Eaton (Maury) MT 7550 series noise gain analyser frequency e
14、xtender 3 models choice according to the frequency domain ? no inside filter ! ? no inside filter ! Great advantage : full compatibility with : - all Agilent/HP sweeps 9350a or b series - - or sweep synthesiser - all Maury/Eaton or Agilent/HP noise/gain analyser F5DQK February 2009 part 2/2 2 to 18
15、GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 13 The choice in the industry Comparaison between Agilent/HP and Eaton/Maury designs With all HP & Eaton versions Only with HP 8970b version Compatibility Far lower Expansive Price Never foundYes but expansive2nd hand choice NoYesDSB and SSB
16、 possibility LowerGreater at low frequencies NF uncertainity at 2 GHz Eaton extenderHP test-set F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 14 HP NF test-set Eaton extender Comparaison between Agilent/HP and Eaton/Maury designs The choice in the in
17、dustry NF uncertainities compared between both extension brands (Eaton point of view) F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 15 Comparaison between Agilent/HP and Eaton/Maury designs The choice in the industry DSB and SSB measures comparaisons
18、, according to Eaton F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 16 2- Direct low-cost DSB measurements on preamplifiers with only an external RF mixer and a sweep generator F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075
19、 or HP 8970b and ADDS 17 Target : maximum gain & NF stability after 0 calibration with Measurements at F2 GHz with external mixer - DSB option choice because microwave amps have a relatively broadband at high frequencies, in comparaison of the IF frequency taken for the meas (like a 5.7 GHz preamp m
20、easured with a 70 MHz IF). - IF choice 30 or 70 MHz - - so both IFs will sure have exactly the same power - Choice of a double or preferably triple balanced mixer - Care taking of optimal (not maximal)LO injection power for minimal insertion loss, between +7 to +13 dBm - Older analyser versions like
21、 the HP 8970a or the Eaton 2075a can be used ! - Older sweep versions like the HP 8350a can also be used (not only the b version like with the HP NF test-set) ! Examples of typical balanced SMA mixers (all tested): +10 to +15double0.01-30.01-3MD-123Macom DC-2.5 0.5-8 0.03-5 0.03-5 0.1-4 IF (GHz) +12
22、double5-1874129Anaren +10triple2-18TB0218Miteq +13triple0.5-19M87CW-J +13triple1-18M83CW-J +10triple2-18M52CW-J P LO opt (dBm)BalanceRF (GHz)ModelBrand W-J = Watkins Johnson F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 18 Measurements at F2 GHz with
23、 external mixer Measurement setup with a 2-18 GHz triple balanced mixer HP 8350 sweep 2-18 GHz mainframe DUT W-J M52C mixer Popt LO = + 8 dBm LO IF RF F5DQK February 2009 part 2/2 2 to 18 GHz NF+gain measuring with Eaton 2075 or HP 8970b and ADDS 19 Gain/Nf measures in DSB with outside LO at frequen
24、cies 2 GHz With HP 8970a analyserWith Eaton 2075 analyser HP 8970aEaton 2075 mastermaster HPIB cableHPIB cable HP 8350a ou bHP 8350a ou b slave sweepslave sweep default address 8default address 8 page 3-701,1SPLED Local Talk onVar RF, ext LO, fixed IFSP1,2Enter Start6000EnterStart 6 GHzStart6000Ente
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- eaton_2075_HP_8970a_part_2 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


