1、I Autoranging CombiScope Instrument PM3370B-PM3380B-PM3390B PM3384B-PM3394B Reference Manual4/1-Dec-2000 RadioFans.CN 收音机爱 好者资料库 II IMPORTANT In correspondence concerning this instrument please give the model number and serial number as located on the type plate on the rear of the instrument. NOTE:T
2、he design of this instrument is subject to continuous development and improvement. Consequently, this instrument may incorporate minor changes in detail from the information provided in this manual. Copyright 1996, 1998 Fluke Corporation All rights reserved. No part of this manual may be reproduced
3、by any means or in any form without written permission of the copyright owner. Printed in the Netherlands Fluke CorporationFluke Industrial B.V. P.O. Box 9090P.O. Box 680 Everett WA7600 AR Almelo 98206-9090, USAThe Netherlands RadioFans.CN 收音机爱 好者资料库 III Thank you for purchasing this FLUKE oscillosc
4、ope. It has been designed and manufactured to the highest quality standards to give you many years of trouble free and accurate measurements The powerful measuring functions listed below have been combined with an easy and logical operation to let you use the full power of this instrument each and e
5、very day. If you have any comments on how this product could be improved, please contact your local FLUKE organization. FLUKE addresses are listed in the back of this REFERENCE MANUAL. There is a USERS GUIDE available containing: -OPERATORS SAFETY -INSTALLATION INSTRUCTIONS -OPERATING INSTRUCTIONS -
6、HOW TO USE THE INSTRUMENT -FUNCTION REFERENCE RadioFans.CN 收音机爱 好者资料库 IV MAIN FEATURES There are five models in this family of Fluke oscilloscopes. Each of these models is a combination of an analog real-time oscilloscope and a fully featured digital storage oscilloscope. By pressing a single push b
7、utton, you can switch the instrument from the analog mode to the digital mode and back. This allows each of the units to be used in an optimum operating mode for all kinds of signal conditions. Complex data streams, modulated waveforms, and video signals can often best be seen in the analog mode of
8、operation. The digital mode of operation is more suited for single events, signals with low repetition frequencies, and when automatic measurements need to be performed. In this family there is a choice of five models. Two models have a bandwidth of 200 MHz, two have a bandwidth of 100 MHz and one h
9、as a bandwidth of 60 MHz. There is a choice of two models with four fully featured channels and three models with 2 channels plus external trigger input, all shown in the following table: In the same instrument family, there are two 200-MHz and two 100-MHz analog oscilloscopes that have specificatio
10、ns similar to the above-mentioned analog/digital combination oscilloscopes operating in analog mode. All analog/digital combination oscilloscopes listed above have the following features: -32K sample acquisition memory in 4 channel versions. -8K sample acquisition memory, expandable to 32K in 2 chan
11、nel versions. -Up to 40 waveforms stored in memory or 204 waveforms with (optional) memory extension. -Autoset function for an instant optimized signal display at the touch of a button. -Auto-ranging attenuators. -Auto-ranging timebase. -Real time clock. Type NumberBandwidthSample rate Number of Cha
12、nnels Input Impedance PM3370B PM3380B PM3384B PM3390B PM3394B 60 MHz 100 MHz 100 MHz 200 MHz 200 MHz 200 MS/s 200 MS/s 200 MS/s 200 MS/s 200 MS/s 2 2 4 2 4 1 M 1 M 1 M 1 M/50 1 M/50 V -Cursor measurements with 1% accuracies. -Extensive set of fully automated voltmeter and time measurement functions.
13、 -Probe operated Touch Hold and Measure function freezes the display and instantly displays the signal frequency, amplitude and dc voltage level. -Peak detection for the capture of glitches as narrow as 5 ns. -Pattern, State and Glitch triggering (2 ns, only in the 4 channel models). -Event delay an
14、d pretriggering and posttriggering. -TV triggering including HDTV and TV line selection. -Serial interface for printing and plotting. -Averaging to reduce signal noise and to increase the vertical resolution from 8 to 16 bits. -Advanced mathematics, including digital low-pass filtering. A Math+ opti
15、on adds integration, differentiation, histogramming, and (as part of a option) FFT. -Sine interpolation and magnification which enables true to life four channel single shot acquisitions with a timebase up to 625 ns/div (32x magnified) -A delayed timebase with full trigger features. -An EIA-232-D in
16、terface (standard) and an GPIB/IEEE-488 interface (optional). -Autocal for automatic fine tuning of all circuitry to achieve maximum accuracy under all user conditions. -Closed case calibration for efficient maintenance of traceable calibration at minimum cost. The following options are available: -
17、A MATH+ option with more automated measurement functions including envelope and measurement pass/fail testing. Also included in this option are Integration, Differentiation, Histogramming, and FFT. -Memory extension offering 32K acquisition memory and the ability to store 204 traces (of 512 samples
18、each) in memory. -IEEE-488.2 interface using the new SCPI (Standard Commands for Programmable Instruments) industry standard for remote control of test and measurement equipment. VICONTENTS CONTENTSPage 1 CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.1VERT
19、ICAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1.1.1Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1.1.2Deflection Modes (Analog Only) . . . . . . . . . . . . . . . . . . . . 1-3 1.1.3Bandwidth . . . . . . .
20、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1.1.4Attenuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1.1.5Input Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1.1.6Coupling . . . . . . . . . . . . . . . . . . .
21、 . . . . . . . . . . . . . . . . . . . . 1-5 1.1.7Dynamic Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1.1.8Position Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1.1.9Trace Separation . . . . . . . . . . . . . . . . . . . . . . . . . .
22、. . . . . . 1-6 1.1.10Max. Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 1.1.11Step Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 1.1.12Signal Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 1.1.13
23、Vertical Accuracies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 1.2TIMEBASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1.2.1Timebase (modes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1.2.2Timebase Settings
24、 (Analog Mode Only) . . . . . . . . . . . . . . 1-9 1.2.3DTB Delay (Analog Mode Only) . . . . . . . . . . . . . . . . . . . . 1-10 1.2.4Timebase Settings (Digital Mode Only) . . . . . . . . . . . . . . 1-10 1.2.5Timebase Delay (Digital Mode Only) . . . . . . . . . . . . . . . . 1-11 1.2.6DTB Delay (
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FLUKE pm33xx_rmeng0400 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
TELEFUNKEN Operette50GWmitUKW 电路原理图.jpg
TELEFUNKEN Opus 49 W 9M65WLK 电路原理图.gif