1、Application Note From the Fluke Digital Librar y y 2x4 wire resistance simplifi es precision measurements Using two wires to measure resistance is convenient, but causes measurement error. You can virtually eliminate this error by using four leads and a multimeter with separate source and measure te
2、rminals. Unfortunately, adding addional leads and connections makes the measurement more complicated. You have additional leads to connect and you may have to swap clips and probes as you change from voltage to resistance. Now a new concept with new technology enables you to take four-wire resis- ta
3、nce measurements with just two leads. Why measure resistance with four wires? Managing two leads can be chal- lenging enough, especially when you are measuring tiny compo- nents in tight spaces. But trying to check a small solder joint, fl ex connector or chip resistor with four leads can be a real
4、trial. Switching lead confi gurations can lead to swapped banana plugs and measurement mistakes. And changing from voltage probes to Kelvin leads and back takes time. So why measure resistance with four wires? Using two wires to measure voltage does not seriously impact measurement accuracy. The vol
5、tage input on a multimeter generally has a 10 Megohm input impedance, so very little current fl ows in the leads, and the result- ing voltage drop in the leads is negligible. Current measure- ments are also not signifi cantly affected by series lead resistance. However, resistance measure- ments are
6、 subject to inaccuracies because of lead resistance. When performing a resistance measurement the multimeter switches a current source into the measurement loop. The current is driven through the unknown resistance and the multimeter measures the resulting voltage drop. If there are only two leads,
7、as shown in Figure 1, the source current travels on the same path used to measure the voltage drop. The measurement leads are not perfect conductors and have some series resistance of their own. By driving the current through the measurement leads, we see not only the voltage drop across the unknown
8、, but also voltage drop for each lead. Thus, we end up measuring the combined resis- tance of the positive lead, the unknown, and the negative lead. If we use four leads, the source current and the measurement can be separated. The meter terminals are called “Source” for the current supply and “Sens