1、I $XWRUDQJLQJ the other functions require only one source trace. Acquired traces or stored traces can be used as source for mathematical operations and can be selected by using the control in the MATH MATH 1 or MATH MATH 2 submenu. For best results, the source traces must be within the dynamic range
2、 of the scope. Inactive traces or empty memory locations cannot be used and the screen will display the message INVALID SELECTION. The result of MATH 1 is always stored in memory location m1. The result of MATH 2 is always stored in memory location m2. When used for mathematical functions, existing
3、memory locations are overwritten. (Use the Copy function to save important traces in another memory location, before using the mathematical functions.) Independent operation enables separate processes to be performed at the same time. When the result of a mathematical function is placed in a registe
4、r memory, functions can be chained together. An example is Ch1*Ch2, with the result being 2 - 2MATHEMATICS integrated to measure power. In this example, MATH 1 is the multiply function with the product placed in m1 and MATH 2 is the integration process, integrating the contents of m1, and placing th
5、e result in m2. The mathematical functions are performed on traces with differing units. Channel 1 shows volts over time, channel 2 shows current over time expressed in Ampres. The resulting trace of the multiplication fuction is expressed in Watts and gives the power over time. The units for the in
6、tegrated trace are Joules. Notes:-The mathematical functions give useful results only if there is no conflict between the units. For example, you cannot add ampres to volts. -The trigger delay and the timebase setting of the two traces must be equal. This is always guaranteed if the traces were acqu
7、ired at the same time (i.e., they are elements of the same register). Note:Appendix A gives the complete menu structure of the MATH menu. Remote commands: CPL: QW (Command to query a waveform). Refer to the Operating Guide for full details Trace on Ch1 Trace on Ch2 MULTIPLY Result in Register m1.1 F
8、ILTER Result in Register m2.1 math2math1 ST6948 Figure 2.1Example of chained mathematical functions MATHEMATICS2 - 3 2.2DEFINITIONS An example that can be used with the formulas given below, the Probe Adjust signal was sampled and the trace data was sent to a personal computer using the RS-232-C ser
9、ial interface and the Query Waveform command of CPL. The settings used and the most important elements of the response received were as follows: SettingsAttenuator200 mV/div CouplingDC Offset-1.5 div = -300 mV offset. Timebase200 s/div Delay-2.50 div = 500 s pretrigger view DataSYMBOLPARAMETERVALUET
10、YPE YuY-unitsVstring XuX-unitssstring YzY-zero0.3number XzX-zero-0.0005number YrY-resolution3.125e-005number XrX-resolution4e-006number YrngY-range65535number dT-corrdT-correction4688E-04number Nsample count512number Y1sample 19603binary Y2sample 29612binary . . . . . . . . . . . . . . . YNsample N-
11、9599binary The following paragraphs give some definitions and formulas that enable you to interpret the preceding data. The same definitions, symbols, and formulas will be used to describe the discrete mathematical functions of the Mathplus processing functions. DefinitionsYou can describe a wavefor
12、m using two one- dimensional arrays that contain wave sample information: S1.N and T1.N. In both arrays the index n (range : 1.N) corresponds to the sample number. Data in the S array represents the amplitude of the waveform in volts of each sample, Data in the T array represents the sample time in
13、seconds of each sample. A waveform is sometimes expressed in other units. For example, an FFT waveform gives a range of frequencies (T1.TN; expressed in Hz) for the signal amplitude of these frequency components (S1.SN, expressed in dB). 2 - 4MATHEMATICS Formulas: SnSn is the value of sample n, expr
14、essed in Y- units. Y-units are usually volts. SensitivityUsually the sensitivity is expressed in volt/div. In the oscilloscope, the range of the Yn values (Yrng) always equals 216 = 65535, which corresponds with 10.24 divisions on the screen. This gives a maximum vertical resolution of 6400 levels p
15、er division. Sensitivity is expressed in Y-units/division. OffsetOffset is the vertical screen position of the signal ground level, indicated by 1- (excluding Y-pos shift). The offset can be adjusted with the front panel Y POS controls. For calculated traces, the offset can be adjusted with the delt
16、a controls in the MATHematics menu. Offset is expressed in Y-units (volts). NOTE:Traces can also be positioned with the Y-pos control in the RECALL menu, but this does not affect the offset. The reason is that Y-pos is a pure display function, which does not affect the signal sampling nor the calcul
17、ation of a trace using a mathematics function. TnTn is the sample moment, expressed in X-units. X-units are usually seconds. TimebaseIn case of a sampled signal the horizontal scale is called the timebase. The timebase setting is usually expressed in seconds/ division. Without magnification or compr
18、ession, the oscilloscope always displays 50 samples per horizontal division. NOTE:The horizontal scale can differ, like the FFT scale. In this case it is expressed in X-units per division. S n YzY n Yr()+()Yu= Sensitivity6400Yr Yu div - -= OffsetYzYu= T n Xzn1()Xr+()dTcorrXr()Xu+= Timebase50Xr Xu di
19、v - -= MATHEMATICS2 - 5 DelayThe time delay between the trigger and the moment that the first sample is taken. If the delay is negative, the first sample is taken before the trigger. This is called pretrigger view. In pretrigger view, the trigger point (horizontal position of which Tn=0) is indicate
20、d on the screen. The delay or the position of the trigger point can be adjusted with the TRIGGER POSITION control. Delay is usually expressed in X-units (seconds). These values can also be expressed in divisions: NOTE:The X-POS control in the RECALL menu can also be used to position traces horizonta
21、lly, but this does not affect the delay or signal sampling because X-POS is purely a display function. DelayXzdTcorrXr()+()Xu= TriggerpositionXzdTcorrXr()+()Xu= Delay XzdTcorrXr()+() Xr - - 1 50 - -div= Triggerposition XzdTcorrXr()+() Xr - - 1 50 - -div= 2 - 6MATHEMATICS 2.3ADD Description: The ADD
22、function performs a point-to-point addition of two traces, related to the two ground levels (indicated as -). The result of the ADD function is a new trace in a different register. The resulting trace can be scaled, and offset can be added for positioning. NOTE:The front panel keys CH1+CH2 (or CH3+C
23、H4) can also be used to display additional active traces of the sums of these channels. But you can use the mathematical ADD function even after a single shot or on stored traces. Scaling is used to fit the resultant trace onto the screen. The TRACK control adjusts scaling. Vertical positioning is c
24、alled offset. It offsets each sample in the resultant trace with a value so that the trace can be moved vertically. The control adjusts the vertical positioning. The scale factor and the offset factor are displayed in the MATH SCALE menu. Pressing the autoscale softkey automatically selects the sett