FLUKE 45 Manual Supplement 电路图.pdf
《FLUKE 45 Manual Supplement 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE 45 Manual Supplement 电路图.pdf(9页珍藏版)》请在收音机爱好者资料库上搜索。
1、Manual Supplement 1998-2001 Fluke Corporation. All rights reserved. Printed in the U.S.A. Manual Title:45 UserSupplement Issue:2 Part Number:855981Issue Date:5/01 Print Date:January 1989Page Count:8 Revision/Date:4, 7/97 This supplement contains information necessary to ensure the accuracy of the ab
2、ove manual. Enter the corrections in the manual if either one of the following conditions exist: 1.The revision letter stamped on the indicated PCA is equal to or higher than that given with each change. 2. No revision letter is indicated at the beginning of the change. For IEC 61010 1000V, CAT I a
3、Caution identifies conditions and actions that might damage the meter. International electrical symbols used on the meter are shown in the following table. Symbols SymbolMeaning WImportant information. See manual. BAlternating current (AC) FDirect current (DC) DAlternating or direct current (AC or D
4、C) GDiode JGround IFuse TDouble insulation (Protection Class II) PConforms to European Union directives W Warning To avoid possible electric shock or personal injury: Do not use the meter if it is damaged. Before use, inspect the case for cracks or missing plastic. Pay particular attention to the in
5、sulation surrounding the connectors. Inspect the test leads for damaged insulation or exposed metal. Check test lead continuity. Replace damaged leads. Do not use the meter if it operates abnormally. Protection may be impaired. When in doubt, have the meter serviced. Do not operate the meter around
6、explosive gas, vapor or dust. Do not apply more than the rated voltage, as marked on the meter, between terminals or between any terminal and earth ground. RadioFans.CN 收音机爱 好者资料库 45 User Manual Supplement 11/983 Before each use, verify the meters operation by measuring a known voltage. When servici
7、ng the meter, use only specified replacement parts. Use caution when working above 30 V ac rms, 42 V ac peak, or 60 V dc. Such voltages pose a shock hazard. Keep your fingers behind the finger guards on the probe when making measurements. Connect the common test lead before connecting the live test
8、lead. Disconnect the live test lead first. Do not operate the meter with the cover or portions of the cover removed. Connect the meters line power cord to a power receptacle with earth ground. To avoid false readings, which could lead to possible electric shock or personal injury, recharge the meter
9、s battery as soon as the low battery indicator (N) appears. Caution To avoid possible damage to the meter or to equipment under test: Disconnect the power to the circuit under test and discharge all high voltage capacitors before testing resistance, continuity or diodes. Use the proper jacks, functi
10、on and range for your measurement applications. Check the meters fuses, see the Testing Current Input Fuses section before measuring current. On page 2-6, make the following changes: Under Measuring Volts, Resistance, or Frequency, add the following: Note To minimize operator confusion, use first an
11、d second display operation to simultaneously monitor the AC and DC component of a measurement when both are present. Caution To avoid possible damage to the meter or equipment under test, disconnect the power to the circuit under test and discharge all high voltage capacitors before testing resistan
12、ce, continuity or diodes. Manual Supplement45 User 45/01 Under Measuring Current, preceding the first paragraph, add: Caution To avoid possible damage to the meter or equipment under test: Use the proper jacks, function and range for your measurement applications. Check the meters fuses, see the Tes
13、ting Current Input Fuses section before measuring current. Never place the probes across (in parallel with) any circuit or component when the leads are plugged into the mA or A terminal. Never attempt an in-circuit current measurement where the open circuit potential to earth is greater than 1000 V.
14、 Under Diode/ContinuityTesting, preceding the first paragraph, add: Caution To avoid possible damage to the meter or equipment under test, Disconnect the power to the circuit under test and discharge all high voltage capacitors before testing resistance, continuity or diodes. On page 3-2, prior to P
15、RIMARY DISPLAY, add: Note To minimize operator confusion, use first and second display operation to simultaneously monitor the AC and DC component of a measurement when both are present. On page 3-4, under INPUT TERMINALS, in the second paragraph, DELETE: against overloads 45 User Manual Supplement
16、5/015 On page 3-5, replace Table 3-1 with the following: Table 3-1. Maximum Rated Input FunctionInput TerminalsMaximum Rated Input* |zand COM1000 V dc or ac rms and FREQzand COM1000 V ac rms, 2 x 10 7 V-Hz normal mode, or 1 x 10 6 V-Hz common mode (whichever is less) mA D and FREQ100 mA and COM300 m
17、A dc or ac rms protected with 500 mA, 250 V and 440 mA, 1000 V fuses. AB and FREQ10 A and COM10 A dc or ac rms (or 20A dc or ac rms overload for 30 sec. max) protected with 11 A, 1000 V fuse. ezand COM1000 V dc or ac rms on all ranges Gzand COM1000 V dc or ac rms All FunctionsAny terminal to earth10