1、70/73 English Instruction Sheet Page 1 70/73 Series III Multimeter Instruction Sheet W Read First: Safety Information To ensure that the meter is used safely, follow these instructions: Never use the meter if the meter or test leads look damaged. Be sure the test leads and rotary switch are in the c
2、orrect position for the desired measurement. Never measure resistance in a circuit when power is applied. Never touch the probes to a voltage source when the test leads are plugged into the 10 A or 300 mA input jack. To avoid damage or injury, never use the meter on circuits that exceed 4800 volt-am
3、ps. Never apply more than the rated voltage between any input jack and earth ground. Be careful when working with voltages above 60 V dc or 30 V ac rms. Such voltages pose a shock hazard. Keep your fingers behind the finger guards on the test probes when making measurements. Warning To avoid false r
4、eadings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator (N) appears. Symbols W Read First: Safety Information Z Manual Range or Automatic Touch Hold mode T Double Insulation CAT II Overvoltage Installation Category per IEC 1010-1.
5、 Typical CAT II locations include main wall outlets, local appliances, and portable equipment. PN 650454 August 1997 Rev.2, 2/98 1997, 1998 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. RadioFans.CN 收音机爱 好者资料库 70/73 English
6、Instruction Sheet Page 2 Input Jacks 300 mA 10A COM FUSED V ! ! Milliamps Amps Volts, Ohms, Diode Test Common Terminal 600V 70 70 hr2f.eps See Specifications for overload protection. Pushbutton Use the pushbutton to either select a fixed range or put the meter in the Automatic Touch Hold mode. Autor
7、ange The meter defaults to autorange when first turned on. Manual Range Manual ranging is available in V ac, V dc, ohms, A ac, and A dc. Momentary + _ V hr14f.eps To return to autorange, press R for 1 second or turn the rotary switch. RadioFans.CN 收音机爱 好者资料库 70/73 English Instruction Sheet Page 3 Au
8、tomatic Touch Hold Mode W Warning To avoid electric shock, do not use the Touch Hold to determine if a circuit with high voltage is dead. The Touch Hold mode will not capture unstable or noisy readings. The Touch Hold mode automatically captures and displays stable readings. Press R for 2 seconds wh
9、ile turning the meter on. 2 seconds + _ V DC V DC H _ + _ V DC single beep VVV hr3f.eps When the meter captures a new input, it beeps and a new reading is displayed. To manually force a new measurement to be held, press R. Note Stray voltages can produce a new reading. To exit the Touch Hold mode, t
10、urn the meter off. Bar Graph The bar graph shows readings relative to the full scale value of a displayed measurement range and indicates polarity. hr16f.eps RadioFans.CN 收音机爱 好者资料库 70/73 English Instruction Sheet Page 4 Standby If the meter is on but is inactive for an hour (20 minutes in diode tes
11、t), the screen goes blank and displays selected bar graph segments. To resume operation, turn the rotary switch or press R. AC and DC Voltage (K L mL) + _ + _ V AC V DC + _ Volts ACVolts DCMillivolts DC V V V mV hr4f.eps Resistance (e) Turn off the power and discharge all capacitors. An external vol
12、tage across a component will give invalid resistance readings. + _ k hr6f.eps 70/73 English Instruction Sheet Page 5 Diode Test (G) Forward Bias Single Beep Reverse Bias Shorted Open or Good Diode Bad Diode + _ + _ Bad Diode + _ Good Diode + _ hr7f.eps 70/73 English Instruction Sheet Page 6 Continui
13、ty Test ( R ) + _ + _ hr5f.eps If continuity exists (resistance 210 ), the beeper sounds continuously. The meter beeps twice if it is in the Touch Hold mode. Current (? A) W Warning To avoid injury, do not attempt a current measurement if the open circuit voltage is above the rated voltage of the me
14、ter. To avoid blowing an input fuse, use the 10 A jack until you are sure that the current is less than 300 mA. Turn off power to the circuit. Break the circuit. (For circuits of more than 10 amps, use a current clamp.) Put the meter in series with the circuit as shown and turn power on. DC + _ 1 4