1、 REMOTE CONTROL AND PROGRAMMING REFERENCE for the FLUKE 190 family of ScopeMeter test tools = This file contains remote control and programming information for the above-mentioned models with use of the PM9080 Optically Isolated RS232 Adapter/Cable. It consists of the following chapters: 1. INSTALLI
2、NG THE PM9080 2. INTRODUCTION TO PROGRAMMING 3. COMMAND REFERENCE APPENDIXES APPENDIX A ACKNOWLEDGE DATA APPENDIX B STATUS DATA APPENDIX C WAVEFORM DATA APPENDIX D ASCII CODES RadioFans.CN 收音机爱 好者资料库 Page 1.1 = 1. INSTALLING THE PM9080 - Connect the PM9080 to the RS232 port of the computer. If neces
3、sary, use a 9-pin to 25-pin adapter and 25-pin gender changer. - Hook the PM9080 cable to the ScopeMeter. - Turn on the computer and the ScopeMeter. - Make sure that the communication settings match for the RS232 port of the computer and the ScopeMeter. After power-on, the default settings of the Sc
4、opeMeter are as follows: 1200 baud, No parity, 8 data bits, 1 stop bit You can modify the baud rate with the PC (Program Communication) command. See chapter 3 COMMAND REFERENCE. Other settings are fixed. You can modify the computer RS232 port settings to match the above ScopeMeter settings with the
5、following DOS command: MODE COM1:1200,N,8,1 This command assumes that COM1 is the RS232 port used on the computer. Replace COM1 in the above command with COM2, COM3, or COM4 if one of these ports is used. You can place this command in the computer startup file AUTOEXEC.BAT so that the default settin
6、gs for the computer are the same as for the ScopeMeter. If you want to use a higher data transfer speed (baud rate), let your QBASIC program change the settings for both the computer and the ScopeMeter. See the example under the PC (Program Communication) command in chapter 3 COMMAND REFERENCE. Radi
7、oFans.CN 收音机爱 好者资料库 Page 2.1 = 2. INTRODUCTION TO PROGRAMMING * Basic Programming Information * When you have installed the PM9080 as described in the previous chapter, you can control the ScopeMeter from the computer with simple communication facilities, such as GWBASIC, QuickBASIC and QBASIC (prog
8、ramming languages from Microsoft Corporation). All examples given in this manual are in the QBASIC language but will also run in QuickBASIC. QuickBASIC allows you to make executable files from programs so you can start such programs directly from DOS. It is assumed that you have knowledge of these p
9、rogramming languages. QBASIC is supplied with Microsoft MS-DOS 5.0 and higher and Windows 95, 98, and NT, including on-line Help. Features of the syntax and protocol for the ScopeMeter are as follows: - Easy input format with a forgiving syntax: All commands consist of two characters that can be UPP
10、ER or lower case. Parameters that sometimes follow the command may be separated from it by one or more separation characters. - Strict and consistent output format: Alpha character responses are always in UPPERCASE. Parameters are always separated by a comma (, = ASCII 44, see Appendix D). Responses
11、 always end with the carriage return code (ASCII 13). Because the carriage return code is a non-visible character (not visible on the screen or on paper), this character is represented as in the command syntax. - Synchronization between input and output: After receipt of every command, the ScopeMete
12、r returns an acknowledge character (digit) followed by the carriage return code (ASCII 13). This indicates that the command has been successfully received and executed. The computer program must always read this acknowledge response before sending the next command to the ScopeMeter. RadioFans.CN 收音机
13、爱 好者资料库 Page 2.2 * Commands sent to the ScopeMeter * All commands for the ScopeMeter consist of a header made up of two alpha characters sometimes followed by parameters. Example: RI This is the Reset Instrument command. It resets the ScopeMeter. Some of the commands are followed by one or more para
14、meters to give the ScopeMeter more information. Example: SS 8 This is the Save Setup command. It saves the present acquisition settings in memory. The SS header is followed by a separator (space), then followed by the parameter 8 to indicate where to store the settings. The meaning of this parameter
15、 is described in Chapter 3 COMMAND REFERENCE. Some commands require several parameters. Example: WT 9,50,30 This is the Write Time command. This command requires three parameters. The parameters are separated by a comma, which is called the Program Data Separator. You may use only one comma between
16、the parameters. Also refer to the section Data Separators. A code at the end of each command tells the ScopeMeter that the command is ended. This is the carriage return code (ASCII 13) and is called the Program Message Terminator. This code is needed to indicate to the ScopeMeter that the command is
17、 completed so it can start executing the command. Also refer to the section Command and Response Terminators. Page 2.3 * Responses received from the ScopeMeter * After each command sent to the ScopeMeter there is an automatic response from it, indicated as (which you MUST input), to let the computer
18、 know whether or not the received command has been successfully executed. Refer to the Acknowledge section below. There are several commands that ask the ScopeMeter for response data. Such commands are called Queries. Example: ID This is the IDentification query, which asks for the model number and
19、the software version of the ScopeMeter. When the ScopeMeter has received a query, it sends the reply as it does after any command, but now it is followed by the queried response data. The format of the response data depends upon which query is sent. When a response consists of different response dat
20、a portions, these are separated with commas (ASCII code 44). Also refer to the section Data Separators. All response data, as well as following (queried) response data are terminated with the carriage return code ( = ASCII 13). Also refer to the section Command and Response Terminators. Page 2.4 * A
21、cknowledge * After receiving of a command, the ScopeMeter automatically returns the response to let the computer know whether or not the received command has been successfully executed. This response is a one-digit number followed by as response terminator. If is 0, it indicates that the ScopeMeter
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FLUKE 190 Family Remote Control Programming Reference 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-200782.html



Marshall-9100-62-02-Schematic电路原理图.pdf