Fluke_5700A_5720A_Multi-Function_Calibrator_Service_Manual.June_1996 电路图.pdf
《Fluke_5700A_5720A_Multi-Function_Calibrator_Service_Manual.June_1996 电路图.pdf》由会员分享,可在线阅读,更多相关《Fluke_5700A_5720A_Multi-Function_Calibrator_Service_Manual.June_1996 电路图.pdf(570页珍藏版)》请在收音机爱好者资料库上搜索。
1、 5700A/5720A Series II Multi-Function Calibrator Service Manual PN 601630 June 1996 Rev. 1, 3/02 1996, 2002 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. RadioFans.CN 收音机爱 好者资料库 LIMITED WARRANTY the display shows linearity,
2、offset, and scale errors. Keys that multiply and divide the output value by 10 to simplify work on meters with calibration points at decade multiples of a fraction of full-scale. Programmable entry limits used for restricting the levels that can be keyed into the calibrator, preventing access to lev
3、els that may be harmful to equipment or personnel. A s key that provides the capability of displaying the instruments specification at the selected operating point, calibration interval, and specification confidence level. An auxiliary current binding post that allows you to calibrate meters with se
4、parate current inputs without moving cables. Real-time clock and calendar for date stamping reports. Offset and scaling modes that simplify linearity testing of multimeters. Variable phase reference signal output and phase-lock input. Interface for the Fluke 5725 Amplifier. Standard IEEE-488 (GPIB)
5、interface, complying with ANSI/IEEE Standards 488.1- 1987 and 488.2-1987. Selectable normal remote mode or emulation of the Fluke 5100B and 5200A Series calibrators in functions and response to system controller software EIA Standard RS-232C serial data interface for printing, displaying, or transfe
6、rring internally-stored calibration constants, and for remote control of the calibrator. 5700A/5720A Series II Calibrator Service Manual 1-4 Extensive internal self testing and diagnostics of analog and digital functions. A traceable calibration procedure for all modes and ranges that requires only
7、10V, 1, and 10 k external standards, with only occasional independent verification. Fast, simple, automated calibration check providing added confidence between calibration recalls, and data that can be used to document and characterize the calibrators performance between calibration recalls. 1-2. C
8、ontacting Fluke To order accessories, receive operating assistance, or get the location of the nearest Fluke distributor or Service Center, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhe
9、re in the world: +1-425-446-5500 Or, visit Flukes Web site at . 1-3. About this Manual This manual provides complete information for installing the calibrator and operating it from the front panel keys and in remote. It also provides a glossary of calibration-related terms as well as general items s
10、uch as specifications and error code information. The following topics are covered in this manual: Installation Operating controls and features Front panel operation Remote operation (IEEE-488 bus or serial port remote control) Serial port operation (printing, displaying, or transferring data, and s
11、etting up for serial port remote control) Operator maintenance, including how to calibrate the 5700A/5720A Series II Options and accessories 1-4. How to Use this Manual Use the following list to find the location of specific information. Quick setup procedure: 5700A/5720A Series II Operators Referen
12、ce Guide Unpacking and setup: Chapter 2. Installation and rack mounting: Chapter 2; also the rack mount kit instruction sheet AC line power and interface cabling: Chapter 2 Controls, indicators, and displays: Chapter 3 Front panel operation: Chapter 4 Cabling to a UUT (Unit Under Test): Chapter 4 In
13、troduction and Specifications Additional Instruction Manuals1 1-5 Using auxiliary amplifiers: Chapter 4 Self calibration: Chapters 1 and 7 Remote operation (IEEE-488 or serial): Chapter 5 Options and accessories: Chapters 2 and 8 Instrument specifications: The end of this Chapter Theory of operation
14、: Chapter 2 of the 5700A/5720A Series II Service Manual 1-5. Additional Instruction Manuals The 5700A/5720A Series II Calibrators ship with a complete manual set that contains information for the operator and service or maintenance technicians. The set includes: 5700A/5720A Series II Getting Started
15、 Manual (PN 1668111) 5700A/5720A Series II Operator Reference Guide (PN 601648) 5700A/5720A Series II Remote Programming Reference Guide (PN 601655) 5700A/5720A Series II Operator Manual (provided on CD-ROM, PN 1668127, or a printed copy is available for purchase through the Fluke Service Department
16、 under PN 601622) 5700A/5720A Series II Service Manual (provided on CD-ROM, PN 1668127, or a printed copy is available for purchase through the Fluke Service Department under PN 105798) Order additional copies of these instruction manuals separately using the part numbers provided. For ordering inst
17、ructions, refer to the Fluke Catalog or contact a Fluke sales representative. 1-6. Wideband AC Voltage Module (Option 5700A-03) The Wideband AC Voltage Module (Option 5700A-03) can be installed in both the 5700A and 5720A Series II Calibrators. The module is a high-accuracy, low-noise, extremely fla
18、t ac voltage source for calibrating rf voltmeters, with a frequency range of 10 Hz to 30 MHz. Output is in seven ranges from 300 V (-57 dBm) to 3.5 V (+24 dBm) through a Type-N coaxial connector into a 50 load. The output level is selected in volts or dBm through either the front panel controls or u
19、nder remote control. The wideband module also functions with the calibrators output adjust controls that let display the error of a wideband meter in either percentage of output or in decibels. Included with the wideband module is a Type-N output cable and a 50 terminator. The wideband module is cal
20、ibrated to the end of its standard-equipment output cable. 5700A/5720A Series II Calibrator Service Manual 1-6 1-7. Auxiliary Amplifiers The Fluke Model 5725A Amplifier is available to extend the high voltage performance and current range of the calibrator: Interface connectors on the calibrators re
21、ar panel accept cables to directly operate a 5725A. Three amplifiers can be connected to the calibrator at the same time, but only one output can be active at a time. Once you have connected the amplifiers and configured the calibrator in a setup menu, amplifier operation is controlled by the calibr
22、ator. Chapter 4 provides instructions for operating the 5725A. The general specifications at the end of this chapter include specifications for operating the calibrator with the 5725A. For other amplifier specifications, refer to their instruction manuals. Table 1-1 summarizes the extended capabilit
23、ies offered by the 5725A. Brief descriptions of the extended capabilities follow. Table 1-1. Auxiliary Amplifier Data ModelModeRange 5725A AmplifierAC V220 to 1100V rms up to 70 mA, 40 Hz to 30 kHz (50 mA 1 V/m but 3 V/m, add 0.01% of range. Relative Uncertainty 1 C 24 Hours90 Days180 Days1 Year24 H
24、ours90 Days (ppm output + V) (ppm output + V) 220 mV10 nV0 5 + 0.57 + 0.50 8 + 0.50 9 + 0.50 2 + 0.42.5 + 0.4 2.2 V100 nV3.5 + 0.84 + 0.84.5 + 0.80 6 + 0.80 2 + 0.82.5 + 0.8 11 V1 V2.5 + 33 + 33.5 + 30 4 + 30 1 + 31.5 + 3 22 V1 V2.5 + 53 + 53.5 + 50 4 + 50 1 + 51.5 + 5 220 V10 V3.5 + 504 + 500 5 + 5
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Fluke_5700A_5720A_Multi-Function_Calibrator_Service_Manual.June_1996 电路图 Fluke_5700A_5720A_Multi Function_Calibrator_Service_Manual
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-200880.html



Marshall-9100-62-02-Schematic电路原理图.pdf