PHILIPS. PM3311U. Test. Service Manual. CDC-311.电路图.pdf
《PHILIPS. PM3311U. Test. Service Manual. CDC-311.电路图.pdf》由会员分享,可在线阅读,更多相关《PHILIPS. PM3311U. Test. Service Manual. CDC-311.电路图.pdf(194页珍藏版)》请在收音机爱好者资料库上搜索。
1、Operating Manual PM3311(U) :;t;zo;r Tab 1. Operating Manual Tab 2. Bedienungsanleitung - Tab 3. Notice dEmploi PM3325 I.E.C. Bus Operating Manual Service Manual PM3311 (U) Tab 4. Service Manual Tab 5. Modifications Tab 6. Circuit Descriptions Tab 7. Dismantling the Instrument Tab 8. Checking and Adj
2、usting Tab 9. Corrective Maintenance Tab 10. Introduction to Microprocessors Tab 11. Explanation of used Symbols Tab 12. Parts Lists P Additional Diagrams RadioFans.CN 收音机爱 好者资料库 ! b 4. i 4.1. t 4-1 GENERAL INFORMATION INTRODUCTION The PM 3311 Diqital Storage Oscilloscope is a portable, twochannel 6
3、0 MHz measuring jnstrument featuring micro-processor controlled electronic circuits. A compact ergonomic design facilitates the extensive measuring capabilities of the instrument. The versatile circuit arrangement combined with the software of the micro-processor gives a wide range of facilities. in
4、cluding: - Brilliant display. - Pre-trigger view. - Storage ot twdchannels with four different event signals per channel. - JEC-bus optional (with the aid of PM 3325). - Plotter output. - Trigger delay. - Battery powered memory back-up. Furthermore, a large 8 cm x 10 cm screen with illuminated grati
5、cule lines provides for easier viewing, a 10 kV accelerating potential giving a high-intensity trace with a well-defined spot. The oscilloscope is provided with numerous integrated circuits, which ensure stable operation and reduce lOns See also delav - 4% combined with delay In REPETITIVE ONLY 5 ns
6、 . O.lps/div 0.2 L l S . 0 . 2 sldiv 0.5 S . 60 mmldiv 2 % 25 samplesldiv - lnaccuracles (absolute or in %) relate to the indicated reference VaUe. Destgnatron Specificat:on Addrttonal InfOn C.R T. Cathode ray tube Accelerating voltage Screen size Phosphor type Graticule r nation D l 4 - 292 GH/39 1
7、0 kV 8 x l O c m I P31 (GHI Internal Triggering Source Metal backed A B EXT EXT : 10 Line subdivisions along the central vertical I axis shorter 2 mm divisions along the second, fourth, sixth and eight hori- zontal axis. - Sensitivity Internal clearly visible under normal light conditions and contin
8、uously variable Front panel screwdriver sdiustment Adiurted automatlCalV 0.3 div 0.15 div 0.3 V 0.15 V 3v 1.5 v +/- Auto d.c. a.c. TV-frame (t/l picture) at 60 MHz at 40 MHz af 60 MHz at 40 MHz at 60 MHr at 40 MHr Graticule llluminatlon Trace rotation Focus Input vertical Frequency range External Ex
9、t : 10 Slope Modes 20Hz .60MHz dc .60MHz 10Hz .60MHz Acc. to CClR 1625 Ilnes) d.c. 0 . 60 MHZ a.c. 10 H r . 60 MHz 2.5 1 M a / l 2 5 p F a.c. - 0 - d.c. 400V A only B Only Add A and B Input impedance A Max. safe input voltage dc + ac peak d.c. +as. peak Channel B can be inverted RadioFans.CN 收音机爱 好者
10、资料库 - L 4-5 Cleai Memory modes Accumulator memory I S cleared Contents of accumulafor memory are stored in selected register Input signal can be written in accumulator memory Memory system is closed Changes normal display mode (dotjoin) into display of only dots. Memory Number of memories 1 accumula
11、tor memory and 3 store memories In single trace mode Save (3x1 4 1 : 250 1 : 250 Resolution horizontal Resolution vertical Operation modes Single Write Lock Pushbutton Refreshment of accumulator mem takes place, when trigger level is reached.and time set with trigger delay has been passed. Signal is
12、 stored according to position Of trigger delay. During Waiting time accumulator. is displayed and LED NOT TRIGD lights UP. Signal in accumulafor memory is displayed on the screen. After the time set with the trigger delay the memory is over- written by new information. Signal is built-up point by po
13、int at the right-hand side of the screen and moves to the left. When accumulator Is completely filled, information is placed in register 3, next in 2. then in 1 and next in accumulator. After this. roll- mode stops, indicated by flashing RUN light. 4 times single with SAVE in memories 0.2 p ._ 0.2 s
14、idiv Dot ioin 1 V / full scale 1 V / full scale TTL comp. 0 = unblanked (pen down) 1 = blanked (pen up) 2OV PEAK approx. 100 I. B plot after A plot 1.2.8. Plot output Horizontal Vertical A P e n lift open collector output max. load 0.5V at 500 mA conf. Recurrent 5 ns . . . 0.2 s/div Max. permissible
15、 voltage Plot time Plot sequence Intarfacar IEC-Bus Roll 0.5 E ._ 60 minidiv 1.2.9. 1.2.10. 1.2.11. 1.2.12. Optional by means of a plug-in P.C. board Settings and ourput controllable from busline controller With IEC connector. IEC-Bur Local/Remote X-Y Display Y f(t) Y f(xl Bandwidth Accuracy Phase d
16、ifference 0.2 us _ 0 . 2 ddiv From time-base From YA input See YA 1 5 % Distance between signal derived from A and signal derived from B is 1125 div. 0 of stored A signal will be at centre of screen Multiple Dot ioin I S nor :n operation Tube included Display modes Memory Channel display combination
17、s Accumulator Register Covers 2 div. screen height Depends on input selection Information as stored in accumulator can be selected for storage in each of the three register memories and is displayed if display button 15 depressed. +_ 8 div 5 x Total information held In STORE 1.2 or 3 can be inverted
18、. Position Calibration output Frequency Voltage Current Power supply A L i n e voltage 2.5 kHz 3 v 6 mA Vertical position range Vertical expand Memory covers 10 cm screen height. Indicated via LED in display sectlon. Continuous 100 ._ 120 v i 10 % 220 ._ 240 V ? 10 % 50 . 400 Hz f 10 % 2.5 Deflectio
19、n in Xdirection can be derived from time base or from memory contents derived from A-input Horizontal expand x-Y selection Line frequency Power consumption Battery 4-6 Function Type Insulation For memory back-up only 2 pen light batteries of 1.5 V For instance 2 x 1.5 Philips R6P The insulation of t
20、he power supply fulfils the safety requirements of IEC 348 CI. I for metal-encased instruments Environmental characteristics Nore: The characteristics are valid only if the instrument is checked in accordance with the official checking procedure. Derails on these procedures and failure cnteria are s
21、upplied on request by the PHILIPS-organisation , n your countrv. or by M. V. PHlLlPSGLOElLAMPENFABRIEKEM, TEST AND MEASURING DEPARTMENT, EINOHOVEN. THE NETHERLANDS. Ambient temperature + 5 OC . $40 OC -10 OC ._ +40 OC -55 oc ._ +75 oc Altitude Operating Non-operatica Humidity Shock Vibration Dimensi
22、ons Weight I 5000 r n (l5OoO it) 15000 rn (50000 ft) Acc. IEC 68 Ob 30 mls 3 mis Length 460mm Width 316mm Height 154 mm Approx. 12 kg Rated range of use Operating temperature range Storage temperature in accor- dance with MIL 28800 and a maximum at 24 hours on high and low temperature In accordance
23、with IEC 68-2.13 test M lnstrumenr withstands 95 % RH over a temperature cycle of 25 OC to 40 OC Inon-operating1 Operating: half sinewave shock of 11 ms duration; 3 shocks per direction for a total of 18 shocks. Operating; vibrations in three directions with a maximum of 20 mm. per direction; 10 min
24、utes with a frequency of 5 - 25 Hz and amplitude of 1,016 mm p-$3; 10 min with a frequency of 25.55 HZ and an amplitude of 0.5 mm p-p. An extra 10 minutes of the resonant of frequency with the hqhest rise in ampli- tude. Unit mounted on vlbra- tion table without shock absorbing material. Handle and
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PHILIPS. PM3311U. Test. Service Manual. CDC-311. 电路图 PHILIPS PM3311U Test Manual CDC 311.
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-200903.html



Marshall-9100-62-02-Schematic电路原理图.pdf